Home Companies Shandong Decho Building Materials Technology Co., Ltd

Roofing Materials Aluminium Zinc Az150 ASTM A792m Building Material Anti Finger Galvanized Dx51d+Az Zincalume

Shandong Decho Building Materials Technology Co., Ltd

Contact Us

[China] country

Trade Verify

Address: RM302, Building 3, Zhongde Science Park,Jimo,Shandong

Contact name:admin

Inquir Now

Shandong Decho Building Materials Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Roofing Materials Aluminium Zinc Az150 ASTM A792m Building Material Anti Finger Galvanized Dx51d+Az Zincalume

Country/Region china
City & Province qingdao shandong
Categories Steel Sheets
InquireNow

Product Details

Aluminium Zinc Roofing Materials Az150 ASTM A792m Building Material Anti-Finger Galvalume Dx51d+Az Zincalume

 

Galvalume Steel Coil(55% Aluminium-Zinc Alloy Coated Steel Coil)

Aluminium-zinc steel is composed of an aluminium-zinc alloy structure, consisting of 55% aluminium, 43.4% zinc and 1.6% silicon solidified at a high temperature of 600 degrees Celsius. Its entire structure consists of aluminium - iron - silicon - zinc, the formation of dense tetrameric crystals of an alloy coated steel.

 

Main advantages

1, smooth surface, excellent resistance to atmospheric corrosion, its corrosion resistance life is 2-6 times higher than hot-dip galvanised steel;

2, with good heat and oxidation resistance, it does not change colour for a long time under 300℃, and it can be used for a long time around 500℃. In addition, the heat reflectivity of the product is higher than 75%, which is 2 times higher than that of galvanised sheet;

3, has excellent paintability and good processing performance. The combination of machine material is strong, which is the best choice for colour coated steel sheet substrate. Its processability and weldability are similar to that of hot galvanised sheet, and it can be processed by cold bending and stamping, and has a good appearance.

Applications

Galvalume steel's superior protective characteristics and economical price make it ideal for :

  • Residential and commercial exterior building materials
  • Decking
  • Cladding
  • Cabinetmaking
Tipps
Storage: The product should be stored in a ventilated and dry place such as indoor, warehouse, etc. It should not be placed in an acidic environment for a long time. Outdoor storage should avoid rain to avoid condensation causing oxidation and discolouration.
Transportation: Avoid external impacts, the means of transport must support the steel coils, reduce stacking, and take effective measures against rain.
Processing: Use the same lubricant for cutting as for aluminium sheets. When drilling or cutting aluminium galvanised steel sheets, loose iron filings should be removed promptly.
 
Difference between GI and GL
 
The difference between galvanised steel and aluminium-zinc steel mainly lies in the different coating, the surface of galvanised sheet is evenly distributed with a layer of zinc material, the parent material plays the role of anodic protection, that is to say, the alternative corrosion of the zinc material protects the use of the parent material, and only when the zinc is all corroded to harm the parent material inside.
 
Galvalume Coil composition by weight ratio of 55% aluminum,43.4% zinc,1.6% silicon, at high temperature 600 high temperature solidification and aluminized zinc plate surface is a unique smooth flat gorgeous star flower, the base color is silver white special coating structure makes it has excellent corrosion resistance

Galvalume Coil/ Sheet is mainly used in the construction of household appliances, automobile containers, especially steel structure building, automobile parts, steel plate warehouse manufacturing and other industries. Their characteristics are mainly: strong corrosion resistance, good surface quality, economic and practical.
 

Attentions in Transportation and Storage:

1. Galvanized Steel Coils should be stored in neat and tidy environment to avoid possible corrosioncaused by all kinds of corrasive medium.
2. The ground for storage should be flat, without hard object, and with sufficient loading-bearing capacity.
3. Storage environment should be dry and ventilated. Avoiding storing outdoors or with dew or with wide temp difference.
4. Coil could not be dragged lest the burr caused by slicing will scratch the coil surface underneath. Coil should be handled with care, without hitting any hard object.

 

European Standards EN 10346:2015

StandardsSteel gradeThickness(mm)Width(mm)Coating Mass
(g/square meter)
EN 10346DX51D,
DX52D,
DX53D,
DX54D,
S220GD,
S250GD,
S280GD,
S320GD,
S350GD
S550GD
0.2 - 1.2800 - 1,250AZ100
AZ150
AZ185

America standards ASTM A792M

StandardsSteel gradeThickness(mm)Width(mm)Coating(g/square meter)
ASTM A792MCS(TYPE A, B, C)
FS(TYPE A, B)
DS
DDS
SS GRADE
33(230)
37(255)
40(275)
50(340) CLASS 1~3
80(550) CLASS 1~3
0.2 - 1.2800 - 1,250AZM100
AZM110
AZM120
AZM150
AZM165
AZM180

Japanese Standard JIS G 3321

StandardsSteel gradeThickness(mm)Width(mm)Coating(g/square meter)
JIS G 3321SGLCC
SGLCD
SGLCDD
SGLC400
SGLC440
SGLC490
SGLC570
0.2 - 1.2800 - 1,250Z06(60)
Z08(80)
Z10(100)
Z12(120)
Z14(140)
Z18(180)
Z20(200)
Z22(220)
Z25(250)
Z27(270)

Australian Standard AS1397

StandardsSteel gradeThickness(mm)Width(mm)Coating
AS1397G1~G3
G250
G300
G350
G450
G500
G550
0.2 - 1.2800 - 1,250AZ150
AZ200
Index

Regular spangle / Minimum Spangle

Galvalume/ 55% Aluzinc Steel Coil/Sheets

Thickness0.13-2.0mm
Width600~1500mm
Zinc CoatingAZ30~AZ200 g/㎡
Surface Treatment

AFP (anti-finger print)

Passivated / Chromated 6+,3+, Free; Oiled; Skin-passed

Steel Grade

DX51D/52D/53D/

S250GD/280GD/350GD/550GD

ASTM A792M, CS-B, SS255-SS550

JIS G3302-SGCC, SGCH (Full hard-G550)

Coil I.D.508 / 610 mm
Coil weight2 ~ 20 tons
Packaging

Standard export packing ( Eye to Side)

Vertical Packing ( Eye to Sky) with wooden pallet

Horizontal Packing ( Eye to Side) with wooden pallet

MOQ.16 tons
Loading portTianjin / Qingdao / Rizhao port

 

 

 

Hot Products

40 Years warranty Super-HDP Zinc 275g Pre-Painted Galvanized Steel Beckers Matt RAL9005 Black ...
PVDF Z275 PPGI AZ160 PPGL Beckers Textured Matt RAL9005 RAL9004 Pre-Painted Galvanized Steel Black ...
AZ160 PPGL RAL5020 Wall Cladding Ocean Blue Color Coated Steel Pre-Painted Aluzinc Steel IBR ...
G90=Z180 PPGI RAL7042 Traffic Grey Color Coil Pre-Painted Galvanized Steel IBR Corrugated Roof Panel ...
28 Guage PPGI G90=Z275 RAL7042 Traffic Grey Colour Coil Pre-Painted Galvanized Steel IBR Corrugated ...
0.48*1200 AZ120 PPGL IBR Corrugated Roof Panel Tiles RAL5005 Single Blue Colour Sheet Coil Pre...