Pultruded FRP Online Market |
Verified Suppliers
|
|
OEM Big Air Cooled Chiller Unit Industrial Air Coolers 111 KW - 337 KW
Model HLWH~ | 100SM | 150SM | 195SM | 230SM | 270SM | 290SM | 320SM | |
100SHM | 150SHM | 195SHM | 230SHM | 270SHM | 290SHM | 320SHM | ||
Rated Cooling Capacity | Cooling Capacity (KW) | 101 | 147 | 196 | 232 | 268 | 293 | 316 |
Comp. Input Power (KW) | 34.6 | 48.2 | 63.8 | 70.5 | 82.4 | 90.2 | 98.9 | |
Rated Heating Capacity | Heating Capacity (KW) | 111 | 159 | 212 | 245 | 284 | 311 | 337 |
Comp. Input Power (KW) | 34.1 | 47.4 | 62.8 | 69.2 | 80.8 | 88.4 | 97.2 | |
Refrigerant | R407C | |||||||
Power Supply | 3φ-380V/50HZ | |||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Low & High pressure protection, Low temp. protection, Water flow protection. | |||||||
Number of Refrigeration Circuit | 1 | |||||||
Capacity Control (%) | 0, 50, 75, 100 | |||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | |
Air Cooled Heat Exchanger | Ripple Aluminum Fins Around Copper Pipe | |||||||
Water Cooled Heat Exchanger | Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" |
Water Side Max Pressure (MPa) | 1 | |||||||
Chilled Water Flow(m3/h) | 17.4 | 25.3 | 33.7 | 39.9 | 46.1 | 50.4 | 54.3 | |
Water Pressure Drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | |
Flow of Hot Water(m3/h) | 19.1 | 27.3 | 36.5 | 42.1 | 48.8 | 53.5 | 58.0 | |
Axial Fan | Air Flow ×1000m3/h | 56.8 | 80.4 | 113.6 | 115.2 | 115.2 | 160.8 | 160.8 |
Power×Qty (KW) | 1.2×4 | 2.0×4 | 1.2×8 | 1.2×8 | 1.2×8 | 2.0×8 | 2.0×8 | |
Running Noise dB(A) | 75 | 75 | 75 | 75 | 75 | 75 | 75 | |
Total Weight (Kg) | 1550 | 1960 | 2940 | 3120 | 3300 | 3480 | 3660 | |
Running Weight(Kg) | 1660 | 2140 | 3160 | 3340 | 3550 | 3730 | 3980 |
Note :
1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃ |
Chilled water inlet/outlet temp. 12℃/7℃, Fouling factor: 0.088㎡.°C/KW. |
2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃ |
Hot water inlet/outlet temp. 40℃/45℃; Hot water range: 45℃~45℃; |
2. Chilled Water Range: 5~20℃; Lowest Ambient Temperature: -5℃~43℃; |
3. Heat recovery unit water in/out temperature: 50℃/55℃; |
4.Changes of Specification for lmprovement May Be made without Notice. |
Feature:
4) Air cooled type , no cooling tower needed
Services :
1 . Golden can supply OEM service for customers
2 . Produce heat pump according to customer's special demands
3 . Supply spare parts according to order quantity
4 . General testing and operational test carried out for every unit before delivery
5 . Long warranty period