Guangdong Sanwood Technology Co.,Ltd |
|
Rain Test Chamber IPX34 tests of protection againg water oscilating pipe
Sanwood IPX34 Rain Test chamber
SANWNOOD produce and supply rain spray test chambers of SM-IPX34
series according to the IPX3, IPX4 tests per IEC60529-2013
14.2.3 & 14.2.4.
IPX34 rain test chamber is suitable for the adaptability and
reliability test of electrical and electronic products, materials,
parts and components under rain and temperature conditions, and can
also be used for external lighting and signal device and automobile
lamp shell protection.
Depend on the specimen size, the oscilating pipe radius
can be produced at:
200mm/400mm/600mm/800mm/1000mm/1200mm/1400mm/1600mm. Below the
talbe shows the number of open holes and total water flow at
different tube radius.
To run the IPX3, IPX4 rain spray tests, there are strictly
requirement to the flow rate, the angle of water spray, test
time and the distance from the sample to the spray
nozzle per EN60529 or IEC60529 standards. Sanwood R&D will
provide you professional test solution per specific.
Technical Specification
Model | SM-IPX34-1500 | |
Testing room size | 1400(W)*1100(H)*1000(D) | |
External size | 1850(W)*1900(H)*1200(D) | |
Performance index | Radius of Water spraying ring | 600mm |
Water pipe diameter | φ18mm | |
Nozzle hole diameter | φ0.4mm | |
Aperture spacing | 50mm | |
Swing amplitude | ±45°,±60°,±90°,±180° | |
Rotating speed | 1r/min can also be used for speed regulation without joints | |
Operation Control System | Controller | SANWOOD controller |
Time controller | Imported programmable time computer integrated controller | |
Water pressure control | Electromagnetic flowmeter or manual regulator flow meter | |
Water supply system | Water tank, booster pump | |
Power supply | AC220V 50Hz | |
Safety protection | water leakage, short circuit, motor overheat protection |
IPX3/4 Rain spray test chamber features
1. Meet the requirement of IEC / EN60529 standards IPX3 water spray
test and IPX4 water splash test.
2. The test sample will be put or installed on the center of the
half-round sinuous pipe and make the bottom of the test samples and
the oscillating axis in a horizontal position. During test, the
sample would spin around the center line.
3. Pendulum pipe standard configuration: R400mm and R600mm or other
else. Swing pipe inner diameter: Φ15mm. DillΦ0.4 holes and make the
water spray to the center. The water pressure of the device
entrance is equal to 10m water level, spraying water pressure is
80-100kpa.
4. Water spraying pipe swing angle: 120º,180º,360º, Vertical sides:
60º,90º,175º.
Complete a swing(2*120º) time is 4S.
Complete a swing(2*360º) time is 12S.
5. Can manual default the test parameters, complete testing
automatically shut off the water supply and
pendulum pipe Angle automatic zeroing and automatic eliminate
seeper, avoid scale blockage needle tip.
6. Use Mitsubishi PLC, LCD panel test procedure control box,
stainless steel curved pipe, alloy aluminum frame, stainless steel
shell.
7. Servo drive mechanism, guarantee the pendulum pipe Angle of
precision, the overall pendulum tube structure for hang a wall.
Product Catalog:
Rain Test Chamber IPX34.pdf