Though clear division is not available, "Clean room" term is used in case of building or room. A space enclosed by PVC curtain or resin panel is considered as "Clean booth" in case of willingness to increase the cleanliness factor in a clean room or air-conditioned room. Size is 1.5m to 5m and clean air is introduced in the booth with a provision of FFU (Fan Filter Unit) in the ceiling.
Have become popular in recent years, not on the basis of its size, but considering it as a simple, cheap, movable structure with cleanliness factor and not violating the construction code or Fire services act.
Frame: Aluminum
 
Size and specification:

ProductModular Clean Room
SizeL6450*W5000*H2400mm
Outer frame40*80mm Extruded aluminum
FFU QTY16 SETS
LIGHT36W*8
Blower fan120W x6SETS
Nosieabout 54dBA
C viewLightproof anti-static PVC curtain
Top viewStainless steel sheet for sealing
Class100 +1000class
DoorManual sliding door


Application:
Clean room is for the pharmaceutical, microbiological research and scientific experiments, which require partial purification equipment.
With regards to the construction code or fire services act, there is a possibility of conflict with the standards of local authority or company of client. Also, the size that can be erected over a desk is termed as "Simple clean bench"
Following considerations are necessary in case of selection of Clean booth.
1. Calculation of cleanliness factor for inside of booth
2. Selection of wall material
3. Selection of ventilation system
4. Selection of air-conditioning within the booth
1. Calculation of cleanliness factor for inside of booth
Generally, it is determined on the basis of clean room regulations. The parameters considered are rate of circulation, filter type, flow system and ventilation system.
Reference table for rate of circulation

Class of clean roomGeneral numerical valueUSA209E StandardsAverage air current speed
Class 100,00020-30 rotations/h200.005-0.041m/s
Class 10,00030~70 rotations /h700.051-0.76m/s
Class 1,000100-200 rotations/h1500.127-0.202m/s
Class 100200-600 rotations/h250-4000.203-0.408m/s


Rate of circulation per hour (rotations /h) =Average air current speed (m/sec) x discharge area (m2) x 3600sec ÷room capacity (volume) (m3)
 

ItemMedium or high performance filterHEPA filterULPA filter
Filtering capacityClass 10-100000Class 100-10000Class 10
ExamplesNormal officeAfter IC processPRE IC process
PerformanceHigh trapping capacity as compares to coarse particle filterPossessing a trapping of capacity up to 99.97% for 0.3um size particlesProssessing a trapping of capacity up to 99.999% for 0.1um size particles


The air flow capacity and units of FFU to be installed are selected on the basis of the volume of clean booth and the desired class.

Required air flow (m3/min) =targeted room capacity (m3) ×rate of circulation (rotations /h) ÷60
Example)
The FFU air flow for a clean booth with width 3m, length 2m, height 2m and desired class of 10000 is (3×2×2) ×75÷60=15(m3/min)

*Single unit of PAU - A17FFU of our company is compatible.
2. Selection of wall material
Selection should be made on the basis of requirements related to ambient and internal space environment.
Features:
1).Clean booth can offer the part of high clean environment ,can be installed on the top of the place
that need to clean.The air that come out from the FFU will be filtered by the pre filter and HEPA filter ,then the
clean air enter into the work zone vertically to insure the purification requirement
2).the noise less than 52dBA,the air velocity is 0.35-0.6m/s
3). the dimension of the clean booth ,customizes design is available
4).it can be used by single and also can be connected to clean area in strip
5). purification rank : 100 class,1000 class or 10000class
Specifications:
 

ItemHard wall modular clean room
CleanlinessClass 100 to Class 100,000
Dimension (LXWXH)Designed as per customer’s requirements
FFUDimension2x2, 2x4, 4x4 optional
Structural frame materialStainless steel, aluminum alloy
Power supply110V/60HZ/AC; 220V/60HZ/AC
FilterMini pleat HEPA filter/ULPA filter optional
Material of frameAluminum alloy / stainless steel 201/SUS 304
Material of wallTempered glass/Acrylic/Anti-static transparent PVC/Sandwich panel
CeilingAluminium-plastic panel/Tempered glass/Acrylic/Anti-static transparent PVC/Sandwich panel


Optional Accessory:
Air Shower
Pass box
Air conditioner
Pressure gauge
 
Drawing of clean room:
 













































Hot Products

Powder Coated Steel/ Personal Air Shower Room with Width 1000mm Single-leaf Swing doors Air shower...
Small Cleanroom Air Shower for 1 person for narrow area with powder coated steel​ Air shower.pdf ...
Only one door personal air shower room for single person, aluminum swing doors Air shower.pdf ...
Single Person Air Shower for class 100 clean room,remove dust from person by high wind speed High ...
Personal Air shower clean room To Malaysia, Big casing, stainless steel swing doors Air shower.pdf ...
PLC Air shower unit connect with dust collector , control by PLC and touch screen Air shower.pdf To ...