Home Companies Alpha Clean Air Technology Co.,Ltd

Automatic Control Fume Supplementary VAV Laminar Airflow Hood

Alpha Clean Air Technology Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room614,Unit 3 Block 16,pengcheng gardan,donghu Rd,Luohu district,Shenzhen, China

Contact name:bertha

Inquir Now

Alpha Clean Air Technology Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Automatic Control Fume Supplementary VAV Laminar Airflow Hood

Country/Region china
City & Province shenzhen
InquireNow

Product Details

Automatic Control Fume Supplementary VAV Laminar Airflow Hood

 

Supplementary Air Fume Hood

 

Adaptive variable air volume control is to adjust the exhaust air volume of the fume hood and the air volume of the room through the change of the opening degree of the fume hood adjustment window in the laboratory. When the fume hood is operated by someone in front of the fume hood, regardless of the height of the window opening and the width of the air inlet Size and indoor air pressure, always accurately control the face wind speed of the fume hood to the set wind speed such as (0.5m/s); when no one is operating, the wind inlet speed of the window will be automatically reduced to the set wind speed such as (0.3 m /s).

The adaptive variable air volume control system adopts German technology. It is the most advanced variable air volume control technology in the field of fume hoods. The system has strong adaptability, less human intervention, fast response speed, and precise valve control. Reduce energy consumption while fully guaranteeing safety.

Applicable occasions: High-end biochemical laboratories with strict requirements on safety, energy consumption and automation
system structure:
The entire variable air volume exhaust system mainly consists of five major parts: fume hood unit, exhaust fan unit, air supply fan unit, pipeline and computer monitoring terminal. The structure is shown in the figure below.

 

The fume hood unit is the most basic work unit for experimental operations, and is the final control object of the system. The structure diagram of the fume hood is shown in the figure below. Each fume hood unit can be equipped with sensors such as displacement sensors, manned and unmanned sensors, and surface wind speed sensors. These sensors can obtain the use or working status of the fume hood; each fume hood must be equipped with a controller and a regulating valve to realize the whole Various parameters processing and exhaust control of the fume hood.
The exhaust fan unit realizes the exhaust function of the entire building. Generally, a controllable variable frequency motor is used to drive the fan blades to achieve stepless exhaust.
The air supply fan unit monitors the negative pressure status of the entire room. Through the detection and judgment of the indoor and outdoor pressure difference, the air supply fan sends air to the room to ensure proper air pressure in the laboratory and a comfortable working environment in the laboratory.
The computer monitoring terminal is for experimenters or managers to remotely monitor the working status of the entire system through monitoring software, and control specific objects according to user rights.

 

 

 

Program features:
■ VAV Variable Air Volume Ventilation (VAV):

Adopting vav variable air volume ventilation technology, no matter how the height and width of the adjustable window of the fume hood changes, as well as the size of the indoor air pressure, by adjusting the exhaust air volume, the surface wind speed of the fume hood is guaranteed to be constant.
■ Automatic control (Auto):

The adaptive and automatic control (Auto) strategy is adopted to obtain whether the fume hood is in a manned operation state through the manned and unmanned sensor, and automatically control the exhaust air. The face wind speed is locked to the set wind speed in the manned and unmanned state respectively, such as (0.35 m/s, 0.3 m/s).
■ Green energy saving (Green):

The system uses adaptive variable air volume exhaust and frequency conversion control to reduce energy consumption to 15% of the traditional exhaust system, allowing users to greatly reduce operating costs, which is green, economical and environmentally friendly (Green).

 

Product NameSupplementary Air Fume HoodProduct NO.L
MaterialaluminumSize4500*1500*900mm
Desk TopMDF, PP, HPL...Brand Name 
MOQ1 SetsDelivery Time15~30days
AccessoriesSocket, Faucet, Gas Fitting, Eyewash, Light,Etc

 

Hot Products

HVAC Ventilation System Air Vent Grilles Ceiling Square Lay In Air Diffuser Lay-in Diffuser is made ...
Beveled Edge Diffuser Corner Square Ceiling Blow Diffusers with Removable Core Bevelled Edge Difuser ...
Quick Install Modular Operation Theatre Room For Hospital With the continuous development of current ...
Easy Installation Operating Theater Surgery Room Modular Panel Assembly Operating Theatre Surgery ...
CLASS I II III IV Modular Operation Theatre Room Fast Construction Clean Room Project Level Name of ...
Laminar Flow With HEPA Operating Room Hospital Ward Construction Operating Theatre Surgery Room ...