Home Companies Xinxiang SIMO Blower Co., Ltd.

Fluidized Boiler Stainless Steel Forced 960r/min Induced Draft Fan

Xinxiang SIMO Blower Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.343, SIMO Road, FengQuan District, XinXiang City, HeNan Province, China

Contact name:Kevin Sun

Inquir Now

Xinxiang SIMO Blower Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Fluidized Boiler Stainless Steel Forced 960r/min Induced Draft Fan

Country/Region china
City & Province xinxiang henan
InquireNow

Product Details

Fluidized Boiler Stainless Steel Corrosion Resistant Forced Draught Blower

 

Centrifugal Fan Of SIMO Blower

 

SIMO Blower —— the centrifugal fan manufacturer,whom has stable product performance, high quality, reliable quality, timely supply and good reputation.

 

SIMO Blower has strong technical force, complete testing and experiment equipment, advanced quality inspection methods, sophisticated manufacturing equipment, complete professional fan processing, dynamic balance testing and special molding abrasive tools. The products have achieved standardization and scale to ensure that the performance and quality of the fan meets the requirements of national standards.

 

The appearance of the product has been carefully polished, the surface is smooth, shiny and bright, giving people a comfortable feeling. Adopting advanced design and manufacturing technology in production technology, each process has undergone strict testing and passed CE certification.

Intimate humanized service: SIMO provides one-to-one personality design; Make a plan first, and then manufacture after customer satisfaction, so as to fully protect the interests of customers.

 

Induced draft fan, high-quality large flow centrifugal fan, fan with more complete models, Choose SIMO Blower with more reasonable price!

 

Technical data

 

Forced Draught Blower

series

Forced Draught Blower

model

Forced Draught Blower

Rotation Speed
(r/min)

Forced Draught Blower

Total Pressure
(Pa)

Forced Draught Blower

Air Capacity
(m³/h)

Forced Draught Blower

Power
(kW)

6-068D145018592745110002640015 ~ 22
9D145023533474157003750030 ~ 45
10D145029054289215005150045 ~ 75
11D960 ~ 145015415190227006850022 ~ 110
12D960 ~ 145018346176246008900037 ~ 160
13D960 ~ 1450215272483120011300055 ~ 250
14D960 ~ 1450249684063900014100075 ~ 400
15D730 ~ 1450165796503660017200045 ~ 500
16D730 ~ 14501885109804430021100075 ~ 710
17D730 ~ 960212854335320016800090 ~ 280
18D730 ~ 9602386609163100199000110 ~ 355
19D730 ~ 9602658678774200234000160 ~ 500
20D730 ~ 9602946752086700273000200 ~ 630
21D580 ~ 9602050829079500316000200 ~ 800
22D580 ~ 9602250909992200363000220 ~ 1000
23.5D580 ~ 960256710380112000443000220 ~ 1400
25D580 ~ 73067946464134000406000355 ~ 800
26.5D480 ~ 73022367633132000483000220 ~ 1120
28D480 ~ 73024968522156000569000315 ~ 1400
29.5D480 ~ 7302771 ~ 9460183000667000400 ~ 2000

 

Introduction Of Centrifugal Fan

 

When the fan is working, the airflow enters the blade space from the fan axially, and then rotates with the impeller under the drive of the impeller; on the other hand, it increases energy under the action of inertia, leaves the impeller along the radius, and does work by the centrifugal force generated. The fan is called a centrifugal fan.

 

The main components of the centrifugal fan are: impeller, casing, coupling and shaft. The impeller is the main work component that generates wind pressure and transfers energy; the casing is mainly used to introduce gas and exhaust gas, and at the same time convert part of the kinetic energy of the gas into pressure energy; the coupling is used to connect the motor and the fan to transmit torque;the shaft is installed with the motor through a coupling and the impeller is fixed.

 

The centrifugal fan is mainly composed of an impeller and a casing. The impeller of the small fan is directly mounted on the motor, and the large fan is connected with the motor through a coupling or a pulley.

 

Centrifugal fans generally use single-side air intake and use single-stage impellers; those with large flow can be air-intaken on both sides and use two back-to-back impellers, which are also called double-suction centrifugal fans.

 

The principle of gas discharge: When the gas between the blades of the centrifugal fan rotates, the kinetic energy obtained by the centrifugal force is discharged from the periphery of the impeller, guided by the volute-shaped casing, so that it flows to the outlet of the ventilator, thereby being in the center of the impeller. Negative pressure is formed in the part, so that the external airflow continuously flows in and supplements, so that the fan can discharge the gas.

 

FAQ

 

1.Q: What’s the MOQ of your company ?

A: The MOQ is 1set.

2.Q: How long is the delivery time ?

A:5-35 days.

3.Q : What’s your payment terms ?

A : T/T, L/C, or Negotiable.

4.Q: What’s your warranty ?
A: 1 year.

5.Q: Is your company factory or trade company ?

A: We have our own factory, our type is factory +trade.

 

 

Hot Products

16Mn Single Inlet High Air Flow Air Purification High Pressure Centrifugal Fan Introduction Of ...
Heavy Duty AC Motor Antiwear Foundry High Pressure Centrifugal Fan Introduction Of Centrifugal Fan 9...
HG785 Alloyed Steel V-Belt Driving Backward Metallurgy High Pressure Centrifugal Fan Introduction Of ...
Aluminium Alloyed High Temperature Oven Wall Cooling High Pressure Centrifugal Fan Introduction Of ...
HG785 Alloyed Steel Backward Ventilation High Pressure Centrifugal Fan Introduction Of Centrifugal ...
Aluminium Alloyed Long Lifetime Coal Mill High Pressure Centrifugal Fan Introduction Of Centrifugal ...