Home Companies Xinxiang SIMO Blower Co., Ltd.

Industrial Induced Draft Fan In Boiler Harmful Air Exhaust Blower

Xinxiang SIMO Blower Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.343, SIMO Road, FengQuan District, XinXiang City, HeNan Province, China

Contact name:Kevin Sun

Inquir Now

Xinxiang SIMO Blower Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Industrial Induced Draft Fan In Boiler Harmful Air Exhaust Blower

Country/Region china
City & Province xinxiang henan
InquireNow

Product Details

Harmful Air Emissions Industrial Boiler Exhaust Induced Draft Centrifugal Fan

 

Introduction

 

Harmful Air Emissions Industrial Boiler Exhaust Induced Draft Centrifugal Fan is suitable for conveying air and non-corrosive, unnatural and non-viscous gases.

The temperature of the medium is generally not more than 80°C, and the dust and hard fine particles contained in the medium are not more than 150mg/m3.

The fan can also be used in cement kiln decomposition process, steel smelting and other special occasions use of high temperature fan (use heat resistant & high strength material).

Centrifugal fan is applied in industrial boiler, (centrifugal fan can be applied in industrial boiler,) it also can be applied in industrial kilns, blast furnace, Industrial waste heat recovery device, Electrolytic aluminium production line air purification system and other industrial work environment.

According to fan parameters you need, SIMO can make centrifugal blower fan technical solution for you. So please provide air capacity, pressure range, medium temperature, voltage and other requirements, more details will help us design suitable technical solution for you.

 

Technical data

 

PRODUCT PARAMETERS
Centrifugal Fan
Application
TemperatureNormal temperature air, Hot air
Air compositionClean air, Dusty air, Corrosive gas, Combustible gas,Powder materials, Light particle materials
Centrifugal Fan
Performance
Impeller diameter800~900mm
Speed of mainshaft960~2950rpm
Pressure range16680~22314Pa
Flow range3019~11632m3/h
Centrifugal Fan
Structure
BladeForward
Impeller supportSWSI (Single Width, Single Inlet), Impeller overhung.
DrivetrainCouplingCan assign
LubricationOil bath lubrication
Bearing coolingAir cooling, Water cooling, Oil cooling
Centrifugal Fan
System
configuration
MotorABB, SIEMENS, WEG, TECO, SIMO, Chinese brand…

 

Can assign

ImpellerQ235, Q345, SS304, SS316, HG785, DB685...

Casing, Air inlet cone,

Air inlet damper

Q235, Q345, SS304, SS316, HG785, DB685...
Main shaft45# steel(High-strength carbon structural steel), 42CrMo, Stainless steel...
BearingFAG, SKF, NSK, ZWZ…
Centrifugal Fan
Optional
components
System base frame, Protective screening,Silencer, Inlet & Outlet pipeline compensator,
Inlet & Outlet flange, Damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Inverter, Special Electrical Motor,System monitoring Instrument, Lube system, Overhead lube tank etc.


Advantages and Features

 

1.The fan can output higher gas pressure, and can provide more gas flow at the same time, low noise.

2. In the case of using the common base, the installation is very simple and basically does not require the support of professional technicians.

3. The motor shaft is elastically connected with the drive shaft. It is not necessary to tighten the belt or replace the belt frequently, and the maintenance workload is small.

4. The fan system running at normal temperature with an impeller diameter of less than 1400 mm does not require additional configuration of bearing cooling device, which reduces the user's investment and maintenance workload.

 

FAQ

 

1. What parameters need to be provided when you design the industrial centrifugal fans?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

 

Hot Products

High Temperature Explosion Protection High Pressure Centrifugal Fan Introduction The 8-17 series ...
Heavy Duty High Volume Air Purification High Pressure Centrifugal Fan Introduction Customized design ...
Carbon Steel Anti Abrasive Coupling Driven High Pressure Centrifugal Fan Introduction The series ...
Alternating Current High Air Flow Drying High Pressure Centrifugal Fan Introduction 1. Customized ...
High Pressure Efficient Energy-Saving Centrifugal Blower Fan Introduction The 9-08 series high ...
High Pressure Coupling Driving Building Ventilation Centrifugal Blower Fan Introduction It is ...