Home Companies Xinxiang SIMO Blower Co., Ltd.

Explosion Proof Motors Dust Collection Blower Centrifugal 2900r/Min

Xinxiang SIMO Blower Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.343, SIMO Road, FengQuan District, XinXiang City, HeNan Province, China

Contact name:Kevin Sun

Inquir Now

Xinxiang SIMO Blower Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Explosion Proof Motors Dust Collection Blower Centrifugal 2900r/Min

Country/Region china
City & Province xinxiang henan
InquireNow

Product Details

Introduction

 

 Explosion-proof centrifugal fans are divided into two types: motor
explosion-proof and complete machine explosion-proof. Since the
motors used in ordinary fans do not have explosion-proof
performance, the explosion-proof centrifugal fans replace the
standard motor with a motor with explosion-proof performance, which
is often used in some larger models of fans to increase its safety
factor.    

Detail introduction
The Explosion-proof centrifugal fan of the whole machine means that in addition to using an explosion-proof motor, the remaining accessories must have explosion-proof performance. For example, the fan casing, fan impeller, fan belt and belt cover, etc., need to be explosion-proof as a whole.
This series of fans is is mainly composed of impeller, casing, air inlet, regulating door and transmission part.
  
(1) The impeller consists of 12 backward-inclined wing-shaped blades welded between the arc-shaped wheel cover and the flat-shaped wheel disc. The use of airfoil-shaped blades ensures the high efficiency, low noise, and high strength of the fan. The impeller runs smoothly after static and dynamic balance correction. The impeller structures of the ventilation and induced draft fans of the same machine number are the same.
  
(2) Chassis The casing is a volute body welded with ordinary steel plates. The casing of the fan is made of an integral structure. For the induced draft fan, there is a dust cleaning door on the scroll plate, which is appropriately thickened to prevent soot wear and extend its service life.
  
(3) The air inlet is a convergent streamlined overall structure and is fixed on the inlet side of the casing with bolts.
  
(4) Adjustment door: a device used to adjust the flow rate of the fan. It consists of 13 braided blades, all of which are installed axially in front of the air inlet. Due to the external transmission structure, the rotation is flexible and convenient. The adjustment range is from 90° (fully closed) to 0° (fully open). Adjust the position of the door lever, looking from the direction of the air inlet, it is on the right side. For a right-hand cyclone fan, pushing the lever handle from bottom to top will change the direction from fully closed to fully open; for a left-hand cyclone fan, pulling the lever handle from top to bottom will change the direction from fully closed to fully open.
  
(5) The transmission group consists of main shaft, bearing box, coupling, etc. The spindle is made of high quality steel. The rolling bearing water-cooled integral bearing box is used. Therefore, water pipes need to be installed. Water consumption varies depending on the ambient temperature, and is generally considered to be 0.5~1m3/h. The bearing housing is equipped with a thermometer and oil level indicator.
  
Technical data
seriesmodelRotation Speed
(r/min)
Total Pressure
(Pa)
Air Capacity
(m³/h)
Power
(kW)
8-124D290019422108324268695.57.5
4.5D290024622805461697817.511
5D2900303033756333134171522
5.6D2900380542278897188473037
6.3D1450120613736334134195.57.5
7.1D1450153017469066192081115
8D145019422216129692505918.530
9D14502462280518466391223745
10D14503030346225330536665575
11.2D960145016674345235617539745132
12.5D7309601206230524907693962275
14D73096015102972349939749637132
16D730960197138845223414553375250


Product Features

 

Provide factory measurement performance, vibration, and test report to prevent failure and ensure the operation of the fan in good condition.The converging and streamlined air inlet is made into a unitary structure and bolted to the inlet side of the fan.

 

FAQ


1,What parameters need to be provided when you design the industrial centrifugal fans?

A: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2,How about your company’s pre-sales service and after-sales service?
A: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3,Does your company have qualifications?
A: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.

 

Industrial Long Life Blast Furnace Boiler Fan Explosion Proofing 1

Industrial Long Life Blast Furnace Boiler Fan Explosion Proofing 2

Hot Products

Centrifugal Fan with IP55 Water proof standard - High Pressure Centrifugal Fan *, *::before, *:...
Efficient High Pressure Centrifugal Blower Frequency Conversion Motor *, *::before, *::after {box...
High Pressure Centrifugal Fan 380v/220v/440v/10kv Stainless Steel 201/304/316/316L *, *::before, *:...
Motor Frequency Conversion High Pressure Blower s Meeting Customized Speed Requirements *, *::before...
Customized High Pressure Centrifugal Fan with ISO/CE Certification 1 Year *, *::before, *::after ...
Industrial Grade High Pressure Centrifugal Fan Blower with Low Noise Level *, *::before, *::after ...