Home Companies Jiangsu CASI Solar Co., Ltd.

240mm Gel Valve Regulated Sealed Battery 150Ah Maintenance Free Battery For Ups

Jiangsu CASI Solar Co., Ltd.
Active Member

Contact Us

[China] country

Address: 16/F, World Trade Office Building, Gaoyou City, Jiangsu Province, China

Contact name:Stephanie

Inquir Now

Jiangsu CASI Solar Co., Ltd.

240mm Gel Valve Regulated Sealed Battery 150Ah Maintenance Free Battery For Ups

Country/Region china
City & Province jiangsu
Categories Batteries
InquireNow

Product Details

12V 150Ah Deep Cycle Gel Battery Energy Storage Solar System UPS
 
Description

Deep Cycle Gel Battery has better performance than the valve regulated sealed lead-acid battery, strong adaptability to ambient temperature (high and low temperature), ability to withstand long time discharge, cyclic discharge, deep discharge and high current discharge, overcharge and over discharge self-protection, etc. Gel agent for gel battery is fumed silica, fumed silica is a high-purity white odorless nano-powder material with thickening, anti-caking, controlling system rheology and thixotropy, etc. In addition to the traditional application, Deep Cycle Gel Battery has been widely used in colloidal battery in recent years.

 

ModelNominal VoltageCapacity C10WeightDimension
HeightLengthWidth
VAhkgmmmmmm
LCPC 7-121272.310115165
LCPC 12-1212123.810315199
LCPC 17-1212175.516518176
LCPC 24-1212247.2126176166
LCPC 33-1212339.5160195130
LCPC 38-12123811.8175196165
LCPC 50-12125015.7212227138
LCPC 65-12126519.2174350166
LCPC 70-12127021.0212260168
LCPC 80-12128024.0220331176
LCPC 100-121210028.8220331176
LCPC 120-121212033.8235406174
LCPC 150-121215041.5240483170
LCPC 200-121220056.7228522240
LCPC 250-121225070.5228522268

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Product Features

  • Product name: Deep Cycle Gel Battery
  • Capacity range: 7Ah-250Ah
  • Voltage class: 12V
  • Float charge voltage: 13.5V-13.8V
  • Equalized charge voltage: 14.4V-14.7V
  • Long working life: 10years
  • Low self-discharge rate: ≤3%/month
  • High sealed reaction efficiency: ≥99%
  • Widen operation temperature rang: -30℃~55℃
  • Adopting tight assembly technology, it has excellent high rate discharge performance.
  • Excess electrolyte, large thermal capacity of the battery, strong thermal dissipation ability, wide working temperature range.

Advantages

  • Product name: Deep Cycle Gel Battery
  • Specially designed for high current and high power application scenarios, with higher energy density than ordinary batteries
  • Product design life of 10 years
  • Easy maintenance, low TCO cost

Application

  • Solar, wind power generation and wind and solar complementary energy storage systems, power systems, nuclear power plants standby power
  • UPS, emergency lighting backup power
  • Ship, maritime and other backup power
  • Petrochemical system backup power

Compliant standards

  • IEC60896-2-1995
  • TD/T 799-2010
  • GB/T 19638.2-2005
  • GB/T22473-2008
  • YD/T1360-2005
  • JISC8704-2:1999
  • Passed ISO9001.ISO14001, GB/T28001-2001, CE,
  • TLC, CGC certificate

Use of Deep Cycle Gel Battery

  • Product name: Deep Cycle Gel Battery
  • Check before charging and discharging: Before charging and discharging, the insulation of the charging equipment should be checked to see if it is good. Specific method: use 500V megohmmeter to measure the DC charging screen bus not less than 10MΩ.
  • Initial replenishment of electricity: Before putting the battery into use after installation and inspection, it should be balanced and supplemented with 14.1V balanced charging voltage at 25℃ for a single battery, and charged in a constant voltage current-limiting way for the battery pack. The maximum charging current is set to 0.25C10A.
  • Discharge: 1) 12V battery charging and discharging, 250Ah battery with a current of no more than 25A for 10 hours to discharge until the battery termination voltage of 10.8V or more, do not over discharge.

    2) During the discharge process, measure and record the battery voltage, discharge current and ambient temperature every hour, pay attention to the change of ammeter and battery voltage at any time, when the voltage drops to about 12.0V, change to half an hour test. When the measured voltage is 10.8v, stop discharging, open the discharge switch, the discharge is over. And record the discharge termination time, battery voltage, ambient temperature.

    3) After discharge, the battery should be recharged in time, to prevent acidification of the poles, the discharge-charging interval should not exceed 8 hours, so it must be balanced within 8 hours to replenish the electricity, the average charging voltage is set to 14.1V (the average of the measured value of the positive and negative terminals of the battery at 25℃), and the maximum charging current is set to 0.25C10A. The battery will run normally with the float charging voltage of 13.5V. Battery 13.5V.

    4) After discharge, check the discharge capacity at 25℃, it should be not less than 85% of the rated capacity, i.e. 12V250AH battery is not less than 212.5Ah.

Hot Products

Complete 3000w 48vdc 220vac Off Grid Solar Power System Residential Description An Off Grid Solar ...
Monocrystalline Silicon 3000 Watt Solar Energy Off Grid System For Home Description 3000 Watt Solar ...
3000 Watt 48vdc 220vac Off Grid Solar Power System Home Use Rooftop Description Off Grid Solar Power ...
5000 Watt 48vdc 220vac 380vac Off Grid Solar Power System Solar Power Generator Description Off Grid ...
5000w 48vdc 220vac 380vac Off Grid Solar Power System Solar Kit Ground Description Off grid solar ...
5000watt 48vdc 220vac 380vac Off Grid Solar Power System Independent Electricity Description Off ...