Home Companies Guangzhou Wonderfu Automotive Equipment Co., Ltd

Touch Screen Portable Ac Recovery Recycle Recharge Machine Fully Automatic

Guangzhou Wonderfu Automotive Equipment Co., Ltd
Active Member

Contact Us

[China] country

Address: 3rd Floor, No. 6 BLOCK, No.15 Jingu Road, Xiutang Village, Huadong Town, Huadu District, Guangzhou

Contact name:Sales Manager

Inquir Now

Guangzhou Wonderfu Automotive Equipment Co., Ltd

Touch Screen Portable Ac Recovery Recycle Recharge Machine Fully Automatic

Country/Region china
City & Province guangzhou
Categories Plastic Extruders
InquireNow

Product Details

Touch Screen AC Refrigerant Recovery Machine Automatic Operation With CE

 

 

 

How is recovered refrigerant replaced into the Air Conditioner?

 

To recover the refrigerant from a vehicle, a licensed and certified technician will connect hoses to both the high and low side connectors on the air conditioning system. The hoses are usually attached to a recovery and recharge machine. With the hoses connected and the hose valves open, the technician will set the machine to slowly remove the refrigerant from the vehicle and store it in a special canister. When the procedure is complete, the technician will verify that the system is indeed empty before proceeding with repairs.

 

 

Why need to flushing and cleaning AC system ?

 

Once an AC system has been contaminated or has suffered a failure , the most important part of the AC service to restore the cooling performance to the system = FLUSHING . WITHOUT proper flushing procedures , seizing a new or rebuilt compressor is a real possibility . The AC compressor must be lubricated at all times . The AC compressor is the only moving part in the entire system and the only reason for oil in the system . The oil is being circulated throughout the system , that means that all the components ( condenser , hoses , tubes , evaporator , drier , accumulator ) have some coating of oil internally . If any dirt , debris or contamination happened in the system all components are affected . Removing the oil ( and oil film inside the components ) will eliminate all of the contamination from the AC system . It’s the oil that attracts and holds contaminants within the system . Remove the old oil = remove the contamination . The AC system must be flushed whenever the AC compressor is being replaced/removed or whenever there is indication of contamination within the system . Make it a habit to remove and inspect the orifice tube ( if the system is so equipped ) . The orifice tube inlet filter screen will always tell a story about the condition of the auto AC system . Any debris or foreign material found on the orifice tube should cause you to look for other indications of contamination .

 

Feature:

 

  • Fully-Automatic Function: Program to recover, vacuum, leak test and charge without operating panel valves.
  • Automatic Oil Drain: A display reminds you to empty the graduated container to show the amount of oil to replace.
  • Save & print before and after service data: Allows the user to store before and after service information by vehicle and print this information to provide to a customer.
  • Visual & Audible Alarm: Notifies the user when service is complete, or if a problem has occurred.
  • Vacuum Leak Test: Monitors level after evacuation, informs of possible leak.
  • Automatic Air Purge: Eliminates system-damaging air without monitoring gauges or opening valves.
  • Automatic Refrigerant Refill: Maintains a user-selectable amount of refrigerant in an internal vessel and signals when it’s time to change supply tank, no monitoring required.
  • Vacuum Feature: Defaults to 15 mins, programmable up to 99 mins. “Remaining time” is displayed.
  • Refrigerant Charging: Select a charge mode from high or low side, or use both sides.
  • Refrigerant Management System: Displays refrigerant use and monitors remaining filter life.Prompts appear when 1/3 of filter life remains

 

 

Description:

  • Fully automatic station for recovering, recycling, and recharging R134a refrigerant
  • Thermal Printer For a complete, detailed report.
  • More then 20000 vehicle Data Base
  • Refrigerant Management Each service is saved in station memory, offering the option of creating a customised archive of all refrigerant transactions.
  • Automatic Leak Testing The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm.

 

Product Specification

 

Usage/ApplicationAC Recycle
Operating Range32° - 120°F (0°-50°C)
Tank Capacity15kgs
Hoses2 m
Body MaterialABS
Compressor3/8 HP
Display7 inches 
Filter System150kg
Machine Height118 cm
Voltage220-240 V
Frequency50/60 Hz
Minimum Order Quantity1

 

 

Our service

 

1. OEM Manufacturing welcome : Logo , Product , Package.Aftersale-service.

 

2. After sending, we will track the products for you once every two days , until you get the products.

 

3. We can send the goods to you within 2 working days after deposit or 100% payment into our bank account . If we don't have stock , the time to make each product is different generally , it takes 1 to 30 working days .

 

4. We have a one year guaranty , if the products does not work property as decribed , and the problem is proven to be at our fault , we will provide exchange services for the same specific item.

 

5. Online Technical support

A professional technical team help to solve customer technical problems .

Guide customers to find out where the problem lies, and provide solutions , try to achieve telephone and remote resolution , and make a good record of the problem , ask customer satisfaction after consultation.

 

 

FAQ

 

Q1. What is your terms of packing?

A: Generally, we pack our goods in strong cartons or wood cases. If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.

 

Q2. What is your terms of payment?

A: T/T 30% as deposit, and 70% before delivery, Paypal, Western Union, Money Gram. But the handling charge is not included. We'll show you the photos of the products and packages before shipment.

 

Q3. What is your terms of delivery?

A: EXW, FOB, CFR, DDU.

 

Q4. Are you factory develop this machine ?

A : Yes, we are factory. We have an very exprienced technic team with 22 years experience.

 

Hot Products

Semi Automatic R134a Car Air Conditioning Recovery Unit Introduction of Refrigerant : Refrigerant is ...
R134 AC Refrigerant Recovery Machine Car Air Conditioner Cleaning Machine With CE Certification Why ...
R134 AC Flush Refrigerant Recovery Car Air Conditioner Cleaning Machine How is recovered refrigerant ...
Automotive R134a AC Recovery Machine Refrigerant With Online Support What is refrigerant recovery ...
Touch Screen AC Refrigerant Recovery Machine Automatic Operation With CE How is recovered refrigeran...
R134A AC Recovery Recycle Recharge Machine , Air Conditioning Charging Station Why we need AC ...