Home Companies Guangzhou Wonderfu Automotive Equipment Co., Ltd

Fully Auto Car AC Gas Charging Machine , Car Refrigerant Recovery Machine Unit

Guangzhou Wonderfu Automotive Equipment Co., Ltd
Active Member

Contact Us

[China] country

Address: 3rd Floor, No. 6 BLOCK, No.15 Jingu Road, Xiutang Village, Huadong Town, Huadu District, Guangzhou

Contact name:Sales Manager

Inquir Now

Guangzhou Wonderfu Automotive Equipment Co., Ltd

Fully Auto Car AC Gas Charging Machine , Car Refrigerant Recovery Machine Unit

Country/Region china
City & Province guangzhou
InquireNow

Product Details

Fully Auto Car AC Gas Charging Machine , Car Refrigerant Recovery Machine Unit

 

Description

Wonderfu has brought to more shops worldwide than arguably any other name in the garage equipment business is proud to offer an A/C charging machine to match your needs and busy lifestyle. Especially during the summer months, vehicles are going to need A/C service. Older vehicles will need this performed more regularly, due to leaks and system inefficiencies. That's why you need a fast, reliable way to recharge those drained systems.

The fully automatic X530 lets you do just that. This premium A/C machine recovers, recycles and recharges air conditioning better faster, safer and more completely than other brands. Since user convenience is key, a LCD display on the machine make your operation easyliy.

 

 

Main function

 

a. Recovery / recycling /Vacuum

b. Drain used oil

c. Refill new oil

d. Recharge

e. Foward and backward cleaning to make recycle cleaning ,makes flushing of lines , evaporators , and condensers fast and easy .

f. Condenser and cooling fan included .

g. Main components are originally imported to guarantee excellent .

 

 

Technicial Data

 

ColorGustomized
Load cell accuracy5g
LCD displayWith
Recovery rate97%
Net weight90kg

 

 

Routine Maintenance

 

Add Refrigerant into Refrigerant Cylinder

 

It must add refrigerant into the refrigerant cylinder as follows when the refrigerant quantity inside the refrigerant cylinder is not enough.

a) Regard the external refrigerant source cylinder as a part of the system and connect it with the high pressure connector ( or low pressure connector ) of the equipment.

b) Evacuate the water and air from the high pressure hose(or low pressure hose)to be connected with the equipment.

c) Open the valve on the external refrigerant source cylinder and add refrigerant into the refrigerant cylinder in accordance with the recovery procedure . After the desired quantity is recovered , close the valve on the external refrigerant source cylinder and continue the recovery process till it stops automatically.

d)Close the high pressure valve ( or the low pressure valve ) on the equipment and the procedure to add refrigerant into the refrigerant cylinder is completed.

 

2.Maintenance of Vacuum Pump

 

To ensure a normal running of the vacuum pump , pay attention on the oil type of the vacuum pump . The #1 vacuum pump lubricant oil is used on this machine.

a . Check oil level

 

After vacuum pump running for 1 minute , stop the pump and check the oil level.

 

b . Add oil

 

When the oil level falls down below the lower limit of the oil level sight glass , it must add oil in accordance with following procedures:cut off the electric power of the equipment , open the oil fill cap , slowly add vacuum pump oil till the upper limit of oil level of the sight glass . Replace the oil fill cap to complete the procedure.

 

c . Replacement of oil

 

The oil inside the vacuum pump need be replaced after every 15 hours running and about 300ml vacuum oil are in the pump . Prepare a proper waste oil container before the replacement and undertake the oil replacement procedures as follows : Cut off the electric power of the equipment , open the oil fill cap , open the bottom oil drain plug to drain off the waste oil throughly . The replace the oil drain plug and add the new oil in accordance with adding oil procedures to complete the oil replacement procedures.

 

d . Replacement of Dry Filter

 

The dry filter should be replaced after an accumulated 60-80kgs refrigerant

is recovered . the model and specification of the dry filter should be in conformity

with the recommendation of the supplier . The replacement procedure of the dry

filter is as follows : Cut off the electric power of the equipment and wear gloves , protective apparel and goggles . Take out the front cover and close the valve of the refrigerant cylinder . Use two open-ended spanners to loose the inlet and outlet nuts of the dry filter carefully.Exhaust any remaining air and then loosen the locking ring of the dry filter and take out the fixing nut from the bottom of the dry filter . Replace a new dry filter ( Attention ! Correct direction of the inlet and outlet ! ) and lock it tightly . Use two open-ended spanners to tighten the inlet and outlet nuts of the dry filter carefully . ( Attention ! Avoid any leakage on the connection ! ) Open the valve on the refrigerant cylinder and replace the front cover . Run the recovery procedure and the recovered quantity should not be less than 500ml so that the hose is full of refrigerant . Turn off the equipment electric power and the procedure to replace the dry filter is completed .

 

e . Add new oil in the oil fill bottle .

 

To ensure sufficient oil could be filled continuously in operating , it should add new oil in the oil fill bottle when the oil level is lower than 100ml . The type of the oil must be as same as the oil in the system .

Add new oil with following procedures : Make confirmation that the top ball valve of the oil fill bottle is closed . Disconnect the quick connection adapter on the top of the oil fill bottle and open the cap of the oil fill bottle . Add new oil in desired quantity and then replace the bottle cap and insert it between the quick connection adapters to complete the procedures .

 

f . Remove Waste Oil

 

When : After recovery Procedures is complete done ( the HP and LP gauge shoule be 0 pressure ) , then remove the waste oil.

How : Slowly open the ball valve on the "waste oil" tank . The waste oil will be drain out from the machine .

After the desired quantity is achieved , close the ball valve to complete the new oil fill process .

 

g . Empty Waste Oil Bottle

 

It should empty the waste oil bottle with following procedures : if the waste oil quantity is more than 250ml : take out the waste oil bottle and open the cover to empty it . Then replace the cover and insert the waste oil bottle onto the support to complete the procedure.

 

 

Hot Products

R134A Car Refrigerant Recycle And Recharge Equipment With CE Product Advantages: X530 is popular in ...
Automotive Car AC Recovery Machine Freon Air Conditioner Recharge with LCD Displayer Product ...
220V AC Recovery Recycle Recharge Machine , Air Conditioning Charging Station Features: Recovery, ...
Freon R134a Recovery Recycle Recharge Machine , Air Conditioning Recovery Machine Product Instructio...
Fully Auto Car AC Gas Charging Machine , Car Refrigerant Recovery Machine Unit Description Wonderfu ...
R134a Refrigerant Air Conditioning Recharge And Recovery Machine With Ce Description Wonderfu has ...