Blood Platelet Incubator

 

Appliance:

1. To store blood platelet (20-24℃), biological reagent (2-40℃), chemical products stored at 2-40℃.

2. Suitable for Hospital, blood station, research institute and university labs.

 

Refrigeration System

1. Branded condenser fan.

2. Imported compressor, CFC-free refrigerant.

3. Forced air cooling system, fast cooling speed and uniformity temperature inside.

4. Imported evaporator for safety and longevity.

5. Finned evaporator for more effective cooling and speedy recovery without condensation and accumulated water.

6. Double transparent insulation glass door, filled with inert gas ensure the cooling performance.

 

Temperature Control

1. Microprocessor-based temperature controller, digital temperature display, temperature resolution is 1℃.

2. Standard thermal printer can track and record the change of the temperature all-the-way.

3. Inner with SUS, external with color sprayed steel, foam glass door with electric heating, free from condensation, inner door, perfect insulation performance.

 

Operating Security

1. Japan imported oscillation slide rail for longevity and low sound.

2. High/Low temperature alarms, sensor error alarm, power failure alarm.

3. Two alarm styles: audible buzzing and visual flashing light.

4. Power cord with earth leakage protection.

5. Door ajar alarm.

 

Avoid Falsification and Wrong Operation

Keyboard lock and password protection function, avoid set parameter randomly.

 

Power Failure Protection

When power restores, all devices would kick-off at one time, which could cause great impact to the power network, could lead to circuit breaker tripping. The delay start function would protect the equipment for several minutes during restore period and make sure all devices operate normally.

 

Humanized Design:

1. Disinfection with UV, set disinfection time freely; UV light would off while door open to protect human body.

2. Temperature printer can be set as needed.

3. Wide voltage from 187V~242V.

4. Foam glass door design, better temperature without any affection on read.

5. Self-closed and stop structure design, prevent door shut, easy to use.

6. Patented temperature box design, make the display temperature closer to blood temperature.

7. SUS inner tank, anti-rust, anti-corrosion

 

Parameter:

 

ModelExternal Size mmInternal Size mmVoltage (V/Hz)Power (W)Temperature inside(℃)Climate typeLayers (450ml blood bags)N.W. (Kg)
KDC-5522*600*1050427*360*467220/5019720-24/2-40℃N5 Layers/10 bags60
KDC-10522*600*1300432*462*728220/5028020-24/2-40℃N10 Layers/20 bags80

 

Hot Products

Economic Medical and Laboratory Use Low Speed Benchtop Centrifuge Application: This low speed ...
High Performance Unrefrigerated Benchtop Centrifuge with Swing-out Rotors Application: This ...
Small Size Tabletop 4000RPM Low Speed Medical and Laboratory Digital Centrifuge Application: This ...
China 10ml low speed centrifuge wholesalers, 4000rpm speed lab centrifuge from china! Application: ...
High Speed Refrigerated Centrifuge Similar to SIGMA 3-18K Centrifuge Applications: This high speed ...
Multi-purpose High and Low Speed & High Capacity Desktop Centrifuge Application: It is widely used ...