Home Companies KingPo Technology Development Limited

USB Type-C Connectors and Cable Assemblies Compliance - Figure E-3 Reference Wrenching Strength Continuity Test Fixture

KingPo Technology Development Limited

Contact Us

[China] country

Trade Verify

Address: RM C, 13/F, HARVARD COMMERCIAL BUILDING, 105-111 THOMSON ROAD, WAN CHAI, HK

Contact name:Lynette Wong

Inquir Now

KingPo Technology Development Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

USB Type-C Connectors and Cable Assemblies Compliance - Figure E-3 Reference Wrenching Strength Continuity Test Fixture

Country/Region china
City & Province hong kong hong kong
Categories Testing Equipment
InquireNow

Product Details

 

USB Type-C Connectors and Cable Assemblies Compliance - Figure E-3 Reference Wrenching Strength Continuity Test Fixture

 

E Wrenching Strength Test


Type-C plugs on cable assemblies and fixtured plug component parts without overmold shall be tested using the mechanical wrenching test fixture, as illustrated in Figure E-1. The fixture substitutes machined metal parts for the receptacle. For plug component part testing, the supplier shall provide a plug test fixture that conforms to the specified plug overmold dimensions for the Type-C plug. See Figure E-2. The fixture may be metal or other suitable material. Perpendicular moments are applied to the plug with a 5 mm ball tipped probe for a period of at least 10 seconds when inserted in the test fixture to achieve the defined moments in four directions of up or down (i.e., perpendicular to the long axis of the plug opening) and left or right (i.e., in the plane of the plug opening). Compliant connectors shall meet the following force thresholds:

 

   a) A moment of 0-0.75 Nm (e.g., 50 N at 15 mm from the edge of the receptacle) is applied to a plug inserted in the test fixture in each of the four directions. A single plug shall be used for this test. Some mechanical deformation may occur. The plug shall be mated with the continuity test fixture after the test forces have been applied to verify no damage has occurred that causes discontinuity or shorting. The continuity test fixture shall provide a planar surface on the mating side located 6.20 ± 0.20 mm from the receptacle Datum A, perpendicular to the direction of insertion. No moment forces are applied to the plug during this continuity test. Figure E-3 illustrates an example continuity test fixture to perform the continuity test. The Dielectric Withstanding Voltage test shall be conducted after the continuity test to verify plug compliance.

 

   b) The plug shall disengage from the test fixture or demonstrate mechanical failure (i.e., the force applied during the test procedure peaks and drops off) when a moment of 2.0 Nm is applied to the plug in the up and down directions and a moment 3.5 Nm is applied to the plug in the left and right directions. A new plug is required for each of the four test directions. An example of the mechanical failure point is shown in Figure

 

Hot Products

IEC 60884-1:2022 clause 8.8 figure 5 Test piston 8.8 Durability The compression force is applied by ...
IEC 60335-2-25-CL.21.101 35N Impact device and 65N Impact device for Microwave Door Assembly Test ...
UL 1017 clause 5.19.4.1 Figure 9 Impactor for testing mechanical strength for brush caps and switch ...
IEC62368 Three Vertical Bar Signal RDL-100 video signal generator 1 Overview 1.1 Product Profile The ...
DIN-VDE0620-1:2021 Bild 16a temperature rise plug gauge Prufestecker 2P+AC 16A DIN-VDE0620-1 plug ...
UL 498 Temperature Rise Socket Gauge Made of Brass and Plastic