Guangdong XWELL New Energy Technology CO., LTD. |
Verified Suppliers
|
|
64 Channel Battery Testing Equipment is a popular newly developed
battery testing system for Li-ion cells, LIPB, Ni-MH cells, Ni-Cd
cells.
This Equipment can be used as research machine, as cell positive
/cathode pole material, battery cycle life testing etc.
This Equipment also can be used in pilot run period and in quality
assurance department, since it has functions as formatting cells,
grading capacity, testing cells group,checking battery pack, and
processing test data,etc.
Principle
The equipment is connected and controlled by computer, sending instructions and collecting data; The keyboard can manually operate the equipment and display parameters and status; Under the command of CPU, the constant current board has the function of constant current and constant voltage; When the battery is charged, the two-way power supply converts the AC into 12V DC, and the charging control and detection of the battery are realized through the constant current board; When the battery is discharged, the process is opposite to charging. Firstly, the battery voltage is increased to 12V through the constant current board, and then the DC is transformed into AC through the two-way power supply, which is directly fed into the AC distribution network of the factory, so as to realize the energy feedback of battery discharge electric energy.
Working power | Three-phase five-wire system AC380V±10%, 50HZ | ||
Work environment | Temperature 0-40 degrees, relative humidity ≤80% | ||
Heat dissipation | to enter the air naturally and exhaust the air upward | ||
Overall energy saving | over 70% | ||
Channel Parameter | |||
Voltage measuring range | 0-5V, 1MV resolution | ||
Battery voltage range | Charge 0-4.5V: Discharge 4.5-2V | ||
Constant voltage range | 2.5V-4.5V | ||
voltage accuracy | ±(1‰ reading +1‰ full) | ||
Current accuracy | ±(1‰ reading +1‰ full) | ||
Software Function | |||
Control mode | Computer connection equipment work, FCL control | ||
Communication mode | RS485 baud rate 57,600 | ||
Process set | A maximum of 32 work steps and 256 cycles are se | ||
Charging mode | Constant current, constant pressure | ||
Charging cutoff condition | Voltage, current, time, capacity | ||
Discharge | constant current | ||
Discharge cut-off condition | Voltage, time, capacity | ||
Defensive function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc | ||
Time range | Set it anywhere from 0 to 30,000 minutes | ||
Time accuracy | ≤±1‰ | ||
Sampling inspection period | ≤3S | ||
Minimum frequency of data recording | ≤5S | ||
Battery sorting | By capacity, time, discharge platform, etc | ||
Data processing | Data, graphs, and loop diagrams |
XWELL can provide different fixtures for different types of cells