Home Companies Shaanxi Weland Signal Technology Co.Ltd

OL32D Building Obstruction Light Low Intensity Double Obstruction Light

Shaanxi Weland Signal Technology Co.Ltd

Contact Us

[China] country

Trade Verify

Contact name:Head Office

Inquir Now

Shaanxi Weland Signal Technology Co.Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

OL32D Building Obstruction Light Low Intensity Double Obstruction Light

Country/Region china
InquireNow

Product Details

This OL32D Low Intensity double obstruction light is a stable burning low intensity LED obstruction light designed to meet ICAO LIOL Type A and B requirements. The model can be used to mark obstacles up to 45 meters above the ground that pose a hazard to aircraft at night, such as telecommunication towers, wind turbines, buildings and other tall structures.

OL32D Low Intensity double obstruction light provides an ultra-bright, energy-efficient and cost-effective lighting solution. Adjustable intensity settings allow users to easily switch between 10cd (Type A) and 32cd (Type B).

The double obstruction light is available in two configurations, Universal DC (12-48VDC) or Universal AC (110-240VAC).

Advanced optics use a single LED for lowest power consumption. Corrosion-resistant polycarbonate lenses are specifically designed for use with LEDs to maximize light intensity and uniformity. An integrated sensor in the light is able to detect when the ambient light threshold has dropped sufficiently and the light will automatically start running.

The luminaire contains internal diagnostic checks and alarm contacts for remote monitoring. The alarm relay is energized during normal operation and will release as long as the LED is not lit.

OL32D Low Intensity double obstruction lights can also be used to combine visual and infrared (IR) for pilots using night vision to see.

 

SPECIFICATIONS

 

 

OL32D Low Intensity Double Obstruction Light

 

Mechanical SpecificationsElectrical Specifications

 

Peak Intensity

 

10cd/32cd/200cd

Lens Material

Polycarbonate

 

Working Model

 

Steady on/ Flashing /on off controlled by a switch insideStorage BatteryAGM,GEL,Lithium Battery option

 

Protect Level

 

IP67 Solar Panelmono-crystalline 18% efficiency 

 

LED

 

Super-bright medium intensty Leds Function OptionalSynchronization

 

Temperature

 

-45℃~70℃Mounting4 bolts M6 

 

Automatic Light Control (ALC) 

 

Turn on at night and off at daytime automaticallyOEM Service

Color: Red, Green, Yellow, Blue, White

Flashing frequency

 

KEY FEATURES

 

ENERGY SAVING

  • The obstruction lights can operate with solar panels and batteries in order to offer low power consumption.
  • Will charge under nearly all weather conditions and up to 200 hours of operating capacity.
  • Over 60% cost saving, compared with using traditional types. No cables or electrical infrastructure required, and lab also saves by no need to take heavy to the top.

 

UP-TO-DATE MATERIALS AND TECHNOLOGY

  • We update main components every year with the rapid development of solar panel, batteries and LEDs.
  • We always keep ourselves up-to-date.

 

RELIABLE

  • Designed to meet FAA and ICAO obstruction standards
  • Regulation automatically turns on at dusk and off at dawn.

 

 

Applications

  • Telecomm tower
  • Radio tower
  • Wind turbine
  • Somke stacks & chimney
  • Tall building
  • Power transmission line

 

STANDARS

High-rise building aviation obstacle light configuration scheme
The obstacle lights set up by high-rise buildings and building complexes should be able to see the outline of the object from all directions, and the horizontal direction can also refer to the barrier lights set at a distance of about 45 meters, and the general building should install obstacle lights at the top of it, and the installation height H is calculated from the horizontal ground. Reference Standards: CAAC, ICAO, FAA MH/T6012-2015, MH5001-2013


 

  • When h ≤ 45m, a low light intensity dual aviation obstacle light or low light intensity aviation obstacle light shall be set at the top
  • When 45 < h < 105m, medium light intensity B-type aviation obstacle light shall be set at the top, and low light intensity aviation obstacle light shall be set at 1 / 2 of its height
  • When 105 ≤ h < 150m, medium light intensity type a aviation obstacle light shall be set at the top, and low light intensity aviation obstacle light shall be set at 1 / 2 of its height
  • High light intensity aviation obstruction lamps shall be set at the top of H ≥ 150m and at the interval of 75-105m, and medium light intensity aviation obstruction lamps shall be set between the layers of high light intensity aviation obstruction lamps

 

 

Hot Products

Solar Red Aircraft Warning Lights On Towers Solar Red Aircraft Warning Lights On Towers Light takes ...
The AFS1804DC24V 48V Low Intensity Aircraft Warning Lights On Towers designed in accordance with ...
Control Box for LED Obstruction Light WelandSignalTM Obstruction Light Control Box is specially ...
Mounting Brackets For Low Intensity Obstruction Light This mounting bracket is suitable for ...
Mounting Brackets for Solar Tower Obstruction Light Welandsgianl offers a range of Solar Tower ...
Solar Red Aircraft Warning Lights On Towers Solar Red Aircraft Warning Lights On Towers Light takes ...