Home Companies HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Automobile Air Conditioning Compressor Four Chambers Hydrogen And Nitrogen Leak Detection System

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Contact Us

[China] country

Trade Verify

Address: No.6-36, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou, Guangdong, China

Contact name:Tessa Huang

Inquir Now

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Automobile Air Conditioning Compressor Four Chambers Hydrogen And Nitrogen Leak Detection System

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

Automobile Air Conditioning Compressor Four Chambers Hydrogen and Nitrogen Leak Detection System

 

 

Introduction of Automobile Air Conditioning Compressor Four Chambers Hydrogen and Nitrogen Leak Detection System:

According to the basic leak detection principle of hydrogen and nitrogen, hydrogen and nitrogen are used as tracer gas to fill the workpiece in a vacuum chamber. Then, the hydrogen and nitrogen leak detector can quickly and accurately determine the leakage situation of the workpiece with high accuracy.

 

Detection Process of Automobile Air Conditioning Compressor Four Chambers Hydrogen and Nitrogen Leak Detection System:

1. Workpiece installation and vacuum box closing:

      a. The operator places the workpiece into the vacuum chamber, connects the workpiece interface with the quick connector inside the vacuum chamber, and presses the start button.

      b. Automatically close the vacuum chamber, and the detection cycle begins immediately.

      Note: Grating protectors are installed on both sides of the vacuum chamber. When closing the vacuum chamber door, ensure that there are no objects interfering with the movement of the vacuum chamber in the closing area.

2. Vacuum chamber vacuuming and workpiece vacuuming:

      a. Automatically vacuum the vacuum chamber until the vacuum level inside reaches the set opening pressure.

      b. At the same time, automatically vacuum the workpiece until the vacuum level inside the workpiece reaches the set vacuum value.

3. Workpiece hydrogen nitrogen filling, medium leakage, and fine leakage detection

      a. Automatically fill the workpiece with hydrogen and nitrogen gas at the set pressure until the pressure inside the workpiece reaches the set value.

      b. Medium leakage detection: After the completion of hydrogen and nitrogen filling, the workpiece is automatically maintained under pressure, and whether there is medium leakage is determined based on the pressure drop value inside the workpiece:

          If the pressure drop value inside the workpiece exceeds the set range, the leak detection process will be terminated, and the operation interface will indicate medium leakage and recover the gas.

      c. After the completion of medium leakage, perform micro leakage judgment:

          If the leak detector detects a hydrogen and nitrogen signal exceeding the set value in the vacuum chamber, it indicates that there is fine leakage in the workpiece, and a fine leakage indication signal is provided on the operation interface.

          If the leak detector does not detect hydrogen and nitrogen signals exceeding the set value in the vacuum chamber, it indicates that the workpiece has passed the inspection, and a qualified signal is provided on the operation interface.

4. Vacuum chamber inflation

      a. Automatically fill the vacuum chamber with atmosphere.

      b. At the same time, the hydrogen and nitrogen inside the workpiece are automatically recovered.

5. Workpiece unloading

      a. If the test is qualified:

          The vacuum chamber door automatically opens. The operator disengages the joint inside the chamber from the workpiece interface.

      b. If the test fails:

          Press the confirm button manually and the vacuum chamber door will automatically open. The operator disengages the joint inside the box from the workpiece interface.

      c. If an alarm occurs during the detection process:

          Manually press the confirmation button. The vacuum chamber door automatically opens. Press the fault message prompt on the touch screen to clear the alarm status, and then retest the workpiece.

      Note: For sorting products with leakage detected: 1. Take out one workpiece and leave one workpiece. 2. Continue testing one workpiece left in the chamber according to the normal operating method. This cycle continues until a specific leaking workpiece is detected.

 

Parameter of Automobile Air Conditioning Compressor Four Chambers Hydrogen and Nitrogen Leak Detection System:

 
ModelHJ118
Workpiece to be inspectedAutomobile air conditioning compressor
Vacuum chamber size400mm long * 450mm high * 300mm deep
Number of vacuum chambers4 pieces (each chamber can hold up to 2 workpieces, with 4 tubes inside)
Fine leakage detection gasHydrogen and nitrogen
Indicating hydrogen and nitrogen leakage pressure3.0Mpa (adjustable downwards)
Alarm leakage rate8g/year (adjustable alarm leakage rate)
Cycle time180 chambers/hour
Equipment maintenance alarmDisplay the usage frequency of main accessories on the touch screen and remind the user of the time point for replacing parts
Run timeMust be able to work continuously for 24 hours and ensure the stability of self testing
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

Three Stations Load Box HC9915B Standard for Three Stations Load Box: IEC 60669-1, IEC 60884-1 2013 ...
IEC Test Equipment Flexible Cables Flexing Tester For Completed Flexible Cables Standard: IEC60245-1...
IEC Test Equipment Electric Wire Abrasion Test Apparatus For Completed Flexible Cables Standard: ...
IEC Test Equipment Electric Static Flexibility Test Apparatus For Completed Flexible Cables Standard...
IEC Test Equipment Universal Conductor Resistance Fixture For Power Cable Standard: IEC60245-1 ...
IEC Test Equipment Natural Circulation Heating Cabinet For Polymer Materials Standard: IEC 60884-1 ...