Home Companies SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED

PD-132 Smart Vehicle Loop Detector For Car Parking Barrier Gate Management System

SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED

Contact Us

[China] country

Trade Verify

Address: No.59 Xinhe Road, Shangmugu, Pinghu, Longgang, Shenzhen, Guangdong, China.

Contact name:Manfrid Lee

Inquir Now

SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PD-132 Smart Vehicle Loop Detector For Car Parking Barrier Gate Management System

Country/Region china
City & Province shenzhen guangdong
InquireNow

Product Details

PD-132 Smart Vehicle Loop Detector For Car Parking Barrier Gate Management System

 

PRODUCT DESCRIPTION

 

Loop detectors are used wherever vehicles have to be detected, for example: monitoring and safe guarding access ways or counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems in car parks or activating card dispensers in car parks.

 

Loop detector with direction detecting function that can be used to statistics the vehicle flux. The principle is based on a change in the inductance within the loop which is caused by the metallic components of passing vehicles. The changes are picked up and evaluated by a microprocessor. Ease of use thanks to automatic calibration when the operating voltage is applied.

 

PRODUCT APPLICATIONS

  • Parking lot entrances vehicle detection
  • Parking lot space information acquisition system
  • Electronic police traffic lights snap shot systemTraffic monitoring system

 

TECHNICIAL SPECIFICATIONS

 

Item
Data
Name
Single/Double way vehicle loop detector
Supply voltage
230V AC , 115V AC, 24V DC/AC, 12V DC/AC
Voltage tolerance
+10% / -15%
Power Consumption
4.5VA
Output relays
240V/5A
Operating temperature
-20°C to +65°C
Storage temperature
40°C to +85°C
Frequency range
20 kHz to 170kHz
Reaction time
10ms
Signal holding time
Unlimited / limited when loop is permanently covered 10 minutes
Sensitivity
Adjustable in 4 increments
Loop inductance
Total loop plus connection wiring:50μH to 1000μH.
Ideal is 100μH to 300μH
Loop connection wiring
Maximum length 20 meters, twisted at least 20 times per meter
Size of Housing
78x40x108 mm (L x W x H)

 

MAIN FUNCTION AND FEATURES

 

1) Reset Switch : The reset switch enables the detector to be manually reset during registering and testing and it is a process of system recovery;

 

2) Selectable Pulse Time : This feature sets the length of time that the pulse relay will be lasting for 1 Second or 0.5 Seconds ;

 

3) Pulse Relay Selection : The Pulse Relay may be configured to energize on detection of a vehicle or when the vehicle leaves the loop;

 

4) Sensitivity Reinforcement : This feature sets the un-detecting level to a maximum sensitivity to prevent failing to detect vehicles as big trucks;

 

5) Switch Sensibility Adjustable : 4 sensitivity setting are available on the switches to change sensitivity ;

 

6) Switch Frequency Adjustable : 4 frequency settings are available to prevent signal interference with neighboring loops ;

 

7) Filtering Option : This option is used to provide a delay between detection of the vehicle and switching of the output relay . This relay is normally used to prevent false detection of small or fast moving objects ;

 

8) Permanent Presence Option : This feature ensures the detection of the vehicle will be maintained when the vehicle stays within the loop area for extended periods

Work Indicator

 

Detector will enter into the self-calibration condition with the green LED flash, red LED extinguish once on power, this procession will last 1 second. .the vehicle should not on the loops within the self-calibration. The green LED will not flash, he red LED extinguish after self-calibration. When the vehicle past over the loop ,the red LED on.

 

DIP SWITCH and Wire Jumper

 

DIP1, 2 setting the sensitivity;set the presence output time of relay 1 by DIP3;set the relay2 as presence/pulse output by DIP4; the output time of presence signal set by DIP5;DIP6set the frequency; jumper wire connect to the open end, PIN16 connect to the NO of relay 1. Jumper wire connect to the close end, PIN16 connect to the NC of relay 1.

 

Work Frequency

 

User can change the loop's work frequency which can avoid the cross talk by the adjacent loop or environment frequency. It offers two styles frequency, set by DIP6

 

Sensitivity Adjustable

 

The DIP1,DIP2 on the front panel can adjust the sensitivity. If the vehicle has not any response when test it, the sensitivity should be improved.

 

Packaging & Shipping

 

Packaging:Standard Exported Carton/Wooden Package,customized packing is available too,as your wish! Shipping:Usually 48 Hours After Payment.

 

Hot Products

Long-Life Performance Simple Small And Economic Semi-Auto Tripod Turnstile Solution PRODUCT ...
Single Or Bi-Directional Automatic Reset Anti-Tailing Function Slim Tripod Roller Turnstile Gate ...
Dustproof Semi-Auto Drop Arm Security 304 Stainless Steel ESD Three Arm Turnstile Gate PRODUCT ...
Pedestrian Entrance Factory Price Semi-Automatic Vertical Stand-Up Tripod Turnstile Gate PRODUCT ...
Dual Lane Stainless Steel Electronic Mechanical Access Control Double Tripod Turnstile ABOUT TRIPOD ...
304 Stainless Steel Access Control Waist Tripod Turnstile Gate With 2 Mechanisms Dual lane tripod ...