Home Companies Henan LinkZone Fire Technology Co.,Ltd

5L / S Automatic Fire Water Monitor Firefighting Equipment For Fire Safety

Henan LinkZone Fire Technology Co.,Ltd
Active Member

Contact Us

[China] country

Address: Room 602,Building 6,No.316,lianhua street,High-tech zone,Zhengzhou,China

Contact name:Alex Zhang

Inquir Now

Henan LinkZone Fire Technology Co.,Ltd

5L / S Automatic Fire Water Monitor Firefighting Equipment For Fire Safety

Country/Region china
City & Province zhengzhou
InquireNow

Product Details

 

Automatic Fire Water Monitor

 

Characteristic:

1.7/24/365 video monitoring,each cannon has a 1080P camera.
2.Can tracking moving fire.
3.Automatic tracking,targeting and extinguishing fire.
4.Automatic alarm when there is a fire risk.
5.Temperature and image Sensing technology avoid wrong judgement.

 

Main Components of fire water monitor:
1.1080P CCTV camera.
2.UV detector.
3.Infrared thermal imaging flame detector.
4.Laser transmitter.
5.Dual function cannon head,can spray water column and water mist

 

What's an automatic fire water monitor ?

The Automatic Fire Water Monitor is an automatic firefighting system including control unit and water discharge device.It discharge large volumes of water from a single fixed location, and at high pressure to give it an excellent range of coverage.The Quick Response Fire water Monitor has built-in infrared thermal imaging detector, UV flame detector, closed circuit television camera. Real time dynamic flame location and laser corrector. The Automatic Fire Water Monitor works with the external UV flame detector to eliminate the detection blind area and increase early warning range.


When the Automatic Fire Water Monitor receives the fire early warning signal (UV or IR signal),it will start to rotate to scanning the fire,it's built-in image IR flame detector will rotate along with the water monitor and lock the flame for 3 seconds, then spray water to extinguish the fire. Otherwise, the water monitor will consider it as a false alarm, and the Automatic Fire Water Monitor will return to it's initial position.The time spent from fire started to fire targeted is less than 30 seconds.

 

Specifications:

 
 ZDMS0.6/5S-LZIIZDMS0.6/10S-LZIIZDMS0.8/20S-LZIIZDMS0.9/30S-LZIIZDMS0.8/40S-LZIIZDMS0.8/50S-LZII

Working Voltage

DC36VDC36VDC24VDC24VDC24VDC24V
Rated Pressure0.6MPa0.6MPa0.8MPa0.9MPa0.8MPa0.8MPa
Protection Radius20m28m42m50m52m55m
Rate of flow5L/s10L/s20L/s30L/s40L/s50L/s
Installation Height6~15m6~15m8~35m8~35m8~35m8~35m
Jet radius34m39m56m62m67m73m
Positioning time≤30s≤30s≤60s≤60s≤60s≤60s
Monitoring radius40m40m60m60m80m80m
Flange ConnectionDN50DN50DN80DN80DN100DN100

 

Notices:

1.The side of cannon with label”this side to wall” must be faced to wall when installed.
2.Video line connected from DVR to cannon directly.
3.Signal lines must connect to signal lines of cannon where it is 2m from cannon.
4.Operation panel installed near the exit and 1.5m from ground,and from where operator can see all cannnons controlled by this operation panel.
5.Pls take care when handling cannon as there is UV detector at the bottom of cannon.The UV detetor is fragile.
6.Make sure there is no barrier around the cannon to stop the cannon 360 degree rotate.
7.The ground lead of DVR,earth wire and Lightning protection wire of control console need be connected to your ground lead.

 

 

Scope of applications:

Our Automatic Fire Water Monitor are wildly used in Industrial,commercial and residential fields.Such as airport, high-speed railway station, bus station, hotel atrium, museum, library, TV studio, gymnasium, science and technology museum, exhibition hall, convention center, theater, cinema, civic activity center, industrial plant, chemical plant, gas station, oil port,helicopter hangar, power plants, logistics centers, hospitals, large shopping malls, commercial complexes, colleges and universities, coal mines, warehouses and other places with large space.

FAQ:

Q1: Are you a manufacturer?

A1: Yes. We are a professional and No.1 manufacture of  Automatic Fire Water Monitor which has the most advanced technology.
Q2: What certificates do you have?
A2: We only have CCCF and ISO certificate at present. And we plan to do FM certificate later.
Q3: What are the advantages of your Automatic Fire Monitor?
A3: Our Automatic Fire Monitor adopt the Infrared thermal imaging detecting and targeting technology. Our Fire Water Cannon integrates the following functions: 1. Remote Video Surveillance. 2. Fire Alarm. 3. Intelligent Fire Extinguishing.

 

Hot Products

Product Description: Introducing the Automatic Fire Monitor—a revolutionary product designed to ...
Product Description: The Automatic Fire Monitor is a top-of-the-line product designed to detect and ...
Product Description: The Automatic Fire Monitor is a powerful, reliable and efficient tool for ...
Product Description: This Automatic Fire Monitor is a highly reliable and efficient fire safety ...
Product Description: Automatic Fire Monitor is a highly efficient, reliable and versatile fire ...
Product Description: Automatic Fire Monitor The Automatic Fire Monitor is a powerful and reliable ...