Product Details

15mins Reading One Step Covid POCT Covid-19 2019-NCoV Antigen Rapid Test Kit

 

Product specifications

ApplicationIn vitro qualitative detection of nucleocapsid(N) protein antigen from Covid-19 virus in human nasal (anterior) swab.
Main CompositionTest Cassette, Swab, Sample Extraction Bottle, Sample Extraction Tube, Tube Cap, Dropper, IFU
FunctionCovid-19 Detection
SpecimenNasal swab
AdvantageEasy to use with fast, accurate results
UsageHome test

 

Product Information

Coronaviruses are a large family of viruses which may cause illness in animals or humans. SARS-CoV-2 is an enveloped, single-stranded RNA virus of the β genus. The virus can cause mild to severe respiratory illness and has spread globally. The SARS-CoV-2 Antigen Test Kit (GICA) for home use is a rapid lateral flow immunoassay for the qualitative detection of SARS-CoV-2 directly from nasal (anterior) swab, without viral

transport media. The Kit contains all components required to carry out an assay for SARS-CoV-2.

 

HOW TO PERFORM THE TEST?

1. Remove a Test Device from the foil pouch by tearing at the notch and place it on a level surface.

2. Holding Extraction Reagent bottle vertically, add 10 drops (400μL) to the Extraction tube.

3. Insert the nasopharyngeal (and oropharyngeal) swab sample(s) into the extraction solution, then, mix the swab 10 times.

4. Remove the swabs while pressing against the solution tube in order to extract most of the specimen

5. Place the dropper cap and drop 3 drops (60~70μl) into the sample well.

6. Read the result in 10-15 minutes. Do not read results after more than 20 minutes.

 

[Sample Requirements]
Polyester sponge samples with PP (polypropylene) rods are recommended for sterile sample collection.
(1) Oropharyngeal specimen collection method: collection head slightly tilted, mouth to expose both sides of pharyngeal tonsils.Wipe the pharyngeal tonsils at least three times along the tongue root, and then wipe the posterior pharynx up and down at least three times with a cotton swab.
(2) Method of collecting nasopharyngeal specimens: The sampler gently holds the head of the recipient with one hand and holds the swab with the other hand.Plug the swab into the nostril and penetrate slowly along the bottom of the lower nasal tract.Arc, do not force too hard, to avoid trauma bleeding.When the tip of the swab reaches the posterior wall of the nasopharyngeal cavity, rotate gently once (if it is a reflex cough) and slowly remove the swab.
(3) Sample treatment: The collected samples shall be treated with the sample buffer provided by the kit as soon as possible (if not processed immediately, the samples shall be stored in dried, sterilized and sealed plastic tubes) and stored at 2℃.~ 8℃, not more than 24 hours; -70℃ is stored for a long time, but repeated freeze and thawing should be avoided.

Test Method


Prior to testing, all reagents were returned to room temperature.Testing shall be performed at room temperature.
I. Sample extraction (see Figure 1)
1. Add 400 L (about 10 drops) of sample buffer vertically to the sample extraction tube and then insert the sample into the tube and rotate against the inner wall about 10 times so that the samples in the solution dissolve as much as possible.
2. Squsample q-tip along the inner wall of the extraction tube to retain as much liquid in the tube as possible from the sample, then removed and discarded.
3. Cover the dropper.

 

two.Test procedure (see Figure 2)
1. Remove the test card from the sealing bag.
2. Add 2 drops (about 80 L) of the treated sample extract to the sample hole of the test card and start the timer.
3. The results were read after placing the test card for 15 minutes at room temperature.The results were invalid after 20 minutes.

 

 

Interpretation of test results


NCoV Rapid Covid Test Kit Immunochromatography Sample Requirements 2

Schematic diagram of the test card result judgment:
Invalid ① result: the quality control line (C line) has no reaction line, the detection is invalid, and the test shall be repeated.
② negative result: red ribbon, quality control line (C line) is in color.
③ positive result: two red bands, detection line (T line) and quality control line (C line) are in color.

 

 

Rapid Test Kit Antigen Self Test in 15 mins Nasal Swab 0

Rapid Test Kit Antigen Self Test in 15 mins Nasal Swab 1

Rapid Test Kit Antigen Self Test in 15 mins Nasal Swab 2

Hot Products

SMS Non Woven Disposable Protective Gowns , Disposable Surgeon Gown Hospital Application 1. It is ...
Durable Disposable Isolation Gown Breathable Light Weight Description Isolation clothing, also known ...
SMS Non Woven Disposable Protective Gowns , Disposable Surgeon Gown Hospital Application 1. It is ...
Anti Leakage Disposable Isolation Gowns Strong Adsorption Ability Feeling Soft Product Advantages 1. ...
Safety Disposable Protective Clothing , Full Body Protection Suit Anti Vuris Features 1. Isolation ...
Streile Disposable Protective Gowns / Reinforced Surgical Robe Anti - Bacteria Application 1. It is ...