Features

 

Fast-acting glass tube fuse
1/4" x 1" (6.3 x 25.4mm) physical size
Glass tube, nickel-plated brass endcap construction
For instruments, electronic and small appliance circuits
UL Listed product meets standard 248-14

 

___________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________

 

 

Electrical Characteristics

 

% of Ampere Rating(In)

Blowing Time

100%* In4 hours Min
135%* In1 hour Max
200%* In5 sec Max

 

 

Specification

 

Part.

No.

Ampere

Rating

Voltage

Rating

Breaking

Capacity

I2TMelting

Integral(A2.S)

MFC0100A/B100mA250V/125V

10000A@125 V AC (100mA~10A);

 

35A@250V AC (100mA~1A);

 

100A@250V AC (1.25A~3.5A);

 

200A@250V AC (4A~10A).

 

0.003
MFC0160A/B160mA250V/125V0.008
MFC0200A/B200mA250V/125V0.02
MFC0250A/B250mA250V/125V0.026
MFC0300A/B300mA250V/125V0.047
MFC0315A/B315mA250V/125V0.055
MFC0350A/B350mA250V/125V0.072
MFC0400A/B400mA250V/125V0.10
MFC0500A/B500mA250V/125V0.16
MFC0630A/B630mA250V/125V0.28
MFC0750A/B750mA250V/125V0.49
MFC0800A/B800mA250V/125V0.60
MFC1100A/B1A250V/125V0.8
MFC1125A/B1.25A250V/125V1.6
MFC1150A/B1.5A250V/125V2.5
MFC1160A/B1.6A250V/125V3.2
MFC1200A/B2A250V/125V5.6
MFC1250A/B2.5A250V/125V7.6
MFC1300A/B3A250V/125V14
MFC1315A/B3.15A250V/125V19
MFC1350A/B3.5A250V/125V20
MFC1400A/B4A250V/125V25
MFC1500A/B5A250V/125V42
MFC1600A/B6A250V/125V80
MFC1630A/B6.3A250V/125V96
MFC1800A/B8A250V/125V200
MFC2100A/B10A250V/125V320
MFC2120A/B12A250V/125V470
MFC2150A/B15A250V/125V650
MFC2200A/B20A250V/125V870
MFC2250A/B25A250V/125V1320
MFC2300A/B30A250V/125V1820

 

 

Dimensions - mm

 

 

 

Time-Current Curves

 

 

 

Testing for a Blown Fuse

 

Whilst it is easy to visually inspect the element in a glass fuse to see if it has blown, the majority of fuses have solid, non-transparent bodies that hide the element from view. To test if the fuse is blown, we require a multimeter. Once configured, a multimeter can measure the resistance of the fuse element. Resistance is measured in Ohms 'Ω'. The following tutorial uses a digital multimeter, however the same principles apply when using an analogue multimeter (ie. one with a needle display). If you are using an analogue meter, firstly read the tutorial and then refer to the additional notes at the end.

 

1. Connecting the Test Leads.

The black lead should be connected to the Common socket.
The red lead should be connected to the Ω or Ohms socket.

 

2. Selecting the Correct Setting.

Move the dial to the lowest range of the Ohms scale (200 ohms is the lowest setting on this mulitmeter). This should also power the meter ON. If there is a seperate ON switch, please turn the meter ON. You can see in the picture that the Ohms range is illustrated by a light green band in lower left area.

The 5 different Ohms range settings on this multimeter are;
2M = 2,000,000 ohms or 2 Megaohms (highest resistance setting)
200k = 200,000 ohms
20k = 20,000 ohms
2k = 2,000 ohms
200 = 200 ohms (lowest resistance setting)

 

3. Check the Meter is Working.

Touch the metal tips of the 2 testing leads and whilst holding them together, the meter display should change to show that little or no resistance is present. Power will simply flow from one lead back through the other. When you seperate the two tips, the meter display will return to a 100% resistance state.


4. Measure the Fuse.

Important! Place the fuse on a non-conducting surface such as wood, laminate or plastic. Touch the metal caps at each end of the fuse with the metal tips of the testing leads. There is no polarity so you can use any lead for either fuse cap. Ensure to make good contact by touching a clean metal surface on each cap. Whilst the leads are firmly connected to the fuse, look at the reading displayed on the multimeter.

Note: If you wish to test a fuse still located in a circuit. Please ensure that you have turned off power and disconnected the power source to avoid possibility of electric shock.

 

5. Understanding the Reading.

Fuse is OK: If the meter reading changes to a low resistance value (similar to the result of touching the 2 leads together).

Fuse is Blown: If the meter reading does not change and display still shows the original 100% resistance state.

Don't forget to turn the multimeter OFF when you have finished testing.

 

 

How to use an Analogue Multimeter.

 

Analogue multimeters provide readings by moving a needle over a fixed scale. The testing process is exactly the same.
Choose the correct Ohms range & touch the metal tips of the testing leads together. The need will 'sweep' across the scale to show little to no resistance. A good fuse will generate the same reading.
When the tips are seperated, the needle will show 100% resistance state. A blown fuse will generate the same reading. Make sure that the testing lead tips make a good connection to the metal end caps of the fuse and the fuse is tested on a non-conducting surface.

Hot Products

High Frequencies RF SMD Power Inductors Flat Top Air Core Chip Coil 3.85nF 1.6A Round For Surface ...
Custom Made Ultra-Miniature High Current Surface Mount Square Air Core Inductors 5.5 to 27nH For RF ...
High Q Formed Shaped Heteromorphic Red Copper Air Core Coil Fixed Inductors 3 Turns 300C For for VHF...
1608 1306 1312 1808 Low Reslstance Surface Mount SMD Power Inductor 47uH 20% For VGA Display Card ...
Non-shielded Shielded Surface Mount Power Inductors SMD 10uH 0.65A For Power Supply Features 1. ...
Customized Power Wireless Charger Coil 7uH 5V Transmitter Receiver Induction Shield For Samsung ...