Quick Response Axial Leaded Non-Resettable One Time Ceramic Tube Fuse 2.5A 250VAC With 3.6x10mm Fast Blow Single Cap

 

 

Description


Aolittel HFP fast-acting 3.6 x 10mm axial-leaded fuse constructed with ceramic tube and one-piece nickel-plated endcaps featuring tinned copper axial leads. Small 3.6 x 10mm size offers more design flexibility by doing away with conventional over-capping while providing higher I2t values.

 

___________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________

 

 

Operating Characteristics

 

% of Ampere Rating(In)

Blowing Time

100% * In4 hours Mi
200% * In60 sec Max

 

 

Certifications

 

Voltage Rating

Agency

Ampere Range

Agency File Number

125V/250VUL250mA ~ 5AE340427(JDYX)
C-UL250mA ~ 5AE340427( JDYX7)

 

 

Specification

 

Part

No.

Ampere

Rating

Voltage

Rating

Breaking

Capacity

I2TMelting

Integral(A2.S)

Agency Approvals

ULcUL

 

PSE

HFP 0100A/B100mA250V/125V50A@125V/250VAC0.0015
HFP 0125A/B125mA250V/125V50A@125V/250VAC0.0025
HFP 0160A/B160mA250V/125V50A@125V/250VAC0.0042
HFP 0200A/B200mA250V/125V50A@125V/250VAC0.0065
HFP 0250A/B250mA250V/125V50A@125V/250VAC0.010
HFP 0300A/B300mA250V/125V50A@125V/250VAC0.018
HFP 0315A/B315mA250V/125V50A@125V/250VAC0.020
HFP 0350A/B350mA250V/125V50A@125V/250VAC0.025
HFP 0400A/B400mA250V/125V50A@125V/250VAC0.035
HFP 0500A/B500mA250V/125V50A@125V/250VAC0.060
HFP 0630A/B630mA250V/125V50A@125V/250VAC0.150
HFP 0750A/B750mA250V/125V50A@125V/250VAC0.350
HFP 0800A/B800mA250V/125V50A@125V/250VAC0.5
HFP 1100A/B1A250V/125V50A@125V/250VAC0.6
HFP 1125A/B1.25A250V/125V50A@125V/250VAC1.2
HFP 1150A/B1.5A250V/125V50A@125V/250VAC1.6
HFP 1160A/B1.6A250V/125V50A@125V/250VAC1.8
HFP 1200A/B2A250V/125V50A@125V/250VAC2.4
HFP 1250A/B2.5A250V/125V50A@125V/250VAC3.2
HFP 1300A/B3A250V/125V50A@125V/250VAC6.0
HFP 1315A/B3.15A250V/125V50A@125V/250VAC7.0
HFP 1350A/B3.5A250V/125V50A@125V/250VAC7.5
HFP 1400A/B4A250V/125V50A@125V/250VAC8.0
HFP 1500A/B5A250V/125V50A@125V/250VAC15
HFP 1600A/B6A250V/125V50A@125V/250VAC24
HFP 1630A/B6.3A250V/125V50A@125V/250VAC28
HFP 1700A/B7A250V/125V50A@125V/250VAC36
HFP 1800A/B8A250V/125V50A@125V/250VAC38
HFP 2100A/B10A250V/125V50A@125V/250VAC42
HFP 2150A/B15A250V/125V50A@125V/250VAC45

 

 

Dimension  (mm)

 

                       

NO.

Part Name

Material

1

Cap

Nickel Plated Brass

2

Body

Non-Transparent Ceramic Tube

3

Fuse element

Alloy

4

Lead wire

Tin Plated Copper

 

 

Features


• Single cap, axial leaded, fast-acting fuse
• 3.6 x 10mm physical size
• Ceramic tube, nickel-plated brass endcap construction
• Tinned copper axial leads
• RoHS complaint, lead-free and halogen free
• Designed to UL/CSA 248 Standard
• Fast Acting, Ceramic body fuse in a compact package
• Available in ratings of 0.10 to 15 Amperes

 

 

Average Time Current Curves

 

TIME IN SECONDS

CURRENT IN AMPERES

 

 

Temperature Rerating Curve

 

 

 

Installation Recommendations

 

A: Propose installation way as following picture.

 

a.

Horizontal installation

b.

Vertical installation

Recommended Soldering Parameters

  • Wave Parameters:

Solder Pot Temperature: 260℃ Max

Solder Dwell Time: 2~5s

  • Hand-Solder Parameters:

Solder Iron Temperature: 350±5℃

Heating Time: 5s Max

 

 

 

Why should the DCR of a fuse be measured at a load of no more than 10% and an ambient temperature of 25°C ?

 

The internal resistance of a fuse is an index reflecting its consumed power in the circuit. The higher the resistance, the more power consumed. For fuses, two parameters can be used to check this index: voltage drop or cold resistance.

Voltage drop: the voltage drop reading after the fusing element reaches thermal balance under rated current. To measure it, apply rated current to the fuse and wait until the reading is stable. It may take a few minutes. It is a little inconvenient and time-consuming.

Cold resistance: the reading of cold resistance basically under no load condition, easy and fast.

Therefore, the cold resistance method is always preferred for fuse check. The load of less than or equal to 10% means basically no load or heating condition, so there will be no thermal balance process, while the ambient temperature itself has a certain effect on fuse performance. All performance indexes of a fuse are parameters in ordinary atmospheric condition, i.e. 25°C. The cold resistance of a fuse, if not measured under the above-mentioned conditions, may not be accurate.

Hot Products

High Frequencies RF SMD Power Inductors Flat Top Air Core Chip Coil 3.85nF 1.6A Round For Surface ...
Custom Made Ultra-Miniature High Current Surface Mount Square Air Core Inductors 5.5 to 27nH For RF ...
High Q Formed Shaped Heteromorphic Red Copper Air Core Coil Fixed Inductors 3 Turns 300C For for VHF...
1608 1306 1312 1808 Low Reslstance Surface Mount SMD Power Inductor 47uH 20% For VGA Display Card ...
Non-shielded Shielded Surface Mount Power Inductors SMD 10uH 0.65A For Power Supply Features 1. ...
Customized Power Wireless Charger Coil 7uH 5V Transmitter Receiver Induction Shield For Samsung ...