Explosion Proof Chemical Fume Hood with Movable Sash

 
Product Description

By definition, a fume hood is an enclosure that has a movable sash, an upper airfoil, lower airfoil, and baffles. An enclosure without these features is named a ventilated enclosure.

To the user, the most important feature of a fume hood is the sash. The sash, or sash panels, are the pieces of transparent material-usually glass-that are located at the front of the fume chamber and are movable. The sash position has a huge impact on the airflow within the fume chamber, but the sash is also a barrier between the fume chamber and your breathing zone. It offers protection from other hazards, such as fire and explosion. Using the sash properly is one of the most important things you can do, not only to protect yourself, but to also save energy.

The next component to focus on is the baffles. These are normally located in the rear of the hood, and along with the back wall, create the exhaust plenum. The exhaust plenum has the lowest pressure within the hood, so the air naturally wants to flow there. There are usually slots or holes in the baffles to allow the air to flow into the exhaust plenum. There are many baffle designs, and some perform better than others. The baffles are the most critical component in fume hood performance, so users need to pay close attention to them.

The lower airfoil is also a critical component. The sash normally closes onto this airfoil. It is the nose of the work surface. There are many designs, but typically, they are constructed of metal and are designed to create a stream of air that sweeps across the work surface rearward toward the baffles

Product Parameters
 
                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve + water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
More About the Fume Hood

Do not place objects directly on the work surface. The airstream flowing over and under the lower airfoil is attempting to sweep chemical fumes back toward the baffles. Placing objects directly on the work surface is like putting boulders in that smooth river. It creates rapids, greatly increasing the chances for loss of containment. Everything in the hood should be elevated off the surface one to two inches. Blocks, shelving, or elevators can be used to lift the objects.

Baffles have been designed to organize the airflow through the fume chamber into the exhaust plenum. Never tape notes and such to the baffles or use the hood for storage. Blocking any of the slots or penetrations in the baffles will disrupt the airflow and create turbulence, which increases the loss of containment.

It is not just what happens in the hood that matters, but what happens around the hood as well. For instance, just walking past the hood with a raised sash is almost a guarantee there will be loss of containment. Why does loss of containment matter? The fugitive chemicals escaping the hood contaminate the room air, which means everyone in the lab is breathing these potentially hazardous chemicals.

Detailed Photos
                  
Explosion Proof Chemical Fume Hood with Movable Sash
Explosion Proof Chemical Fume Hood with Movable Sash
 
Explosion Proof Chemical Fume Hood with Movable Sash
Explosion Proof Chemical Fume Hood with Movable Sash
 
Usage Attention

As a best practice, the lower the sash handle is, the safer the user will be. Hoods should never be used at full open-this is for setup only. Working with an 18-inch opening on a vertical sash is far safer than working at full open.  

When you stand in front of the sash opening, your body acts like an airplane wing; the air being drawn into the hood flows over your shoulders and around your sides, creating a low-pressure zone directly in front of you. This low-pressure area in front of you will attempt to pull air from inside the hood outward,  creating a loss of containment and possible exposure. This is why you always work at least six inches behind the sash to keep chemicals out of the area of reverse flow.

Next, extend your hands and arms into the hood and move them about. What are they doing to the airflow? Picture yourself in a canoe, your arms are the paddles, and just as the paddles can displace large amounts of water, your arms can displace large amounts of air creating turbulence and disrupting the airflow. This is a recipe for loss of containment. When working in the hood, move your hands and arms slowly and deliberately.

FAQ

6 Questions to Ask When Buying a Fume Hood:

-Which chemicals will you use within the hood?

-Is a ducted or ductless hood best suited to your needs and available space?

-Where will you place the fume hood in the lab? Consider workflows, access to external exhaust systems, and competing air patterns.

-What size fume hood will best suit your needs? Be sure to consider what (if any) equipment will be enclosed in the hood.

-Are any service fixtures or accessories such as airflow monitors, electrical outlets, water, or gas fixtures required?

-Are base cabinets for acid, solvent, or non-chemical storage required?

Hot Products

Fireproof Explosion Proof Acid & Alkali Resistant Chemical Lab Fume Cupboard Heat Resistant 1. ...
Heat Resistant Acid & Alkali Resistant Chemical Laboratory Duct Fume Hood with Fireproof 1. Product ...
Acid & Alkali Resistant Heat Resistant Chemical Laboratory Duct Fume Hood Explosion Proof Fireproof ...
Acid & Alkali Resistant Heat Resistant Fireproof Chemical Lab Duct Fume Hood Explosion Proof 1. ...
Acid & Alkali Resistant Heat Resistant Fireproof Lab Chemical Duct Fume Cupboard Explosion Proof 1. ...
Fireproof Acid & Alkali Resistant Heat Resistant Chemical Lab Duct Fume Hood Explosion Proof 1. ...