Home Companies Chengdu Ample Import And Export Co., Ltd.

Conventional Laboratory Equipment Chemical PP Fume Hood

Chengdu Ample Import And Export Co., Ltd.
Active Member

Contact Us

[China] country

Address: T2-715, Landmark Plaza, High-Tech Zone, Chengdu, China

Contact name:Mike Ma

Inquir Now

Chengdu Ample Import And Export Co., Ltd.

Conventional Laboratory Equipment Chemical PP Fume Hood

Country/Region china
City & Province chengdu
InquireNow

Product Details

Product Description

Company Info.

Customer Question & Answer

Ask something for more details

  • Overview
  • Product Description
  • Product Parameters
  • Guidelines
  • Detailed Photos
  • Application Cases
Overview

Basic Info.

Model NO.
WXL-1200A-940-1/WXL-1500A-940-1
Customized
Customized
Condition
New
Product Name
Fume Cupboard
Worktop
990*540*300 mm
Input Power
220V/50-60Hz
Face Velocity
0.4-0.6
Application
Office Building, Hospital, School, Laboratory
Cabinet
PP
Illumination
Less Than 500 Lux
Transport Package
Standard Export Wooden Case Packing
Specification
1200*940*1940
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Product Description

Product Description

The fume hood is an important piece of laboratory safety equipment designed to protect personnel and the environment from toxic fumes by drawing air from a contained area. The lining material of a fume hood confers its containment properties and polypropylene offers many advantages in this regard.

Some of these include its impermeability, durability, and resistance to corrosion. For this reason, polypropylene fume hoods are recommended for most applications.

When purchasing a polypropylene fume hood, some factors to consider include the size of the hood-most common sizes run from 3-8 feet, whether your lab has ducting capabilities or if a ductless model is needed, whether a constant volume or variable air volume exhaust system will be used, the material and operating speed of the blower, sash height, and the benchtop material. After purchase, fume hoods require regular maintenance and adherence to safety guidelines; always be sure to follow manufacturer instructions to ensure maximum safety.

Product Parameters
                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Guidelines

1. All operations that may generate hazardous air contaminants must be done inside a laboratory fume hood.
2. Fume hoods do not prevent accidents or chemical splashes. 3. Hood users must be trained in the proper operation and use of laboratory fume hoods.
4. The hood should not be operated unless it is verified that it is working correctly.
5. Safety glasses (goggles), lab coats, and appropriate chemical gloves must be worn when working in, on, or around the fume hood.
6. Do not put your head in the hood, beyond the sash opening.
7. Do not use the hood for storage of equipment, containers, or chemicals which are not going to be used during the day.
8. Equipment and materials placed in the hood must not block hood slots, airfoils, or otherwise interfere with the smooth flow of air into the hood.
9. Never place or use equipment that protrudes beyond the face of the hood (sash opening). This configuration will disrupt air flow of air into the hood and reduce its efficiency.
10. Keep all equipment and materials at least 6 inches behind the plane of the sash (hood face), this will improve containment capture. A stripe (tape) on the hood working surface is a good reminder.
11. Place all bulky equipment away from the sidewalls to allow air flow around the equipment.

Detailed Photos

Conventional Laboratory Equipment Chemical PP Fume Hood
Conventional Laboratory Equipment Chemical PP Fume Hood
Conventional Laboratory Equipment Chemical PP Fume Hood

Application Cases

Inside the fume hood, there are facilities to let you work. For example, there is almost always some good lighting system in the cabinet. There should be LPG and water connections in the hood, and a drain too in case of spills. 
The air suction system is generally placed on top of the box or on the backside (the side towards the wall). This system is generally made up of a strong exhaust fan or air pump and accompanying air duct. The strength of the pump lies in the airflow strength starting from 4 to 8 meters per second to more. 
When the exhaust is running, it sucks in volumes of air through the open side (never run the exhaust with the hood completely closed) and vents it through the duct. The duct may throw the fumes right outside the room in the air, or may run it through a filtration system, depending upon the severity of the experiment.
Some advanced laboratory fume hoods have microcontrollers inside them, which you can use to control the exhaust. You may set various suction levels for given setups and later use these quick setups for particular experiments. You can also control the fan/pump power during the experiment too, and the lights as well. The control panel can also warn you about various inconsistencies, like the presence of smoke or fire or too high a shutter

Conventional Laboratory Equipment Chemical PP Fume Hood
Conventional Laboratory Equipment Chemical PP Fume Hood















Hot Products

Fireproof Explosion Proof Acid & Alkali Resistant Chemical Lab Fume Cupboard Heat Resistant 1. ...
Heat Resistant Acid & Alkali Resistant Chemical Laboratory Duct Fume Hood with Fireproof 1. Product ...
Acid & Alkali Resistant Heat Resistant Chemical Laboratory Duct Fume Hood Explosion Proof Fireproof ...
Acid & Alkali Resistant Heat Resistant Fireproof Chemical Lab Duct Fume Hood Explosion Proof 1. ...
Acid & Alkali Resistant Heat Resistant Fireproof Lab Chemical Duct Fume Cupboard Explosion Proof 1. ...
Fireproof Acid & Alkali Resistant Heat Resistant Chemical Lab Duct Fume Hood Explosion Proof 1. ...