AMAXPOWER NEW ENERGY TECH CO., LTD |
|
Amaxpower 12V 24Ah SMF VRLA Deep Cycle Rechargeable Energy Storage Gel Battery (12V 24Ah)
Amaxpower AGM VRLA Battery 12V 24ah Rechargeable Valve Regulated Lead Acid Battery Solar Battery For Emergency Lighting
Amaxpower GS Series is sealed and free maintenance whole life, valve regulated type standby AGM battery, also named by VRLA battery, SLA battery, and SMF battery.
GS series Sealed free maintenance lead acid batteries are designed with AGM technology, high performance plates and electrolyte to gain extra power output for common power backup system applications widely used in the fields of UPS, Security and Emergency lighting system.
Feature of GS VRLA Sealed Lead Acid Batteries:
1.Sealed and maintenance free operation.
2. 99.99% pure lead plates ensure high quality and high reliability.
3. Safety valve installation for explosion proof.
4. Non-Spillable construction design.
5. Low self-discharge 3% per month.
6. Using oxygen recombination technology: maintenance-free.
7. Pb-Ca-Sn alloy for plate grids, less gassing and less self-discharging.
8. High quality AGM separator, extend cycle life and prevents micro short circuit.
9. Flame resistance ABS material, increases the strength of battery container.
Specification
Nominal Voltage | 12V (6 cells) | |
Nominal Capacity | 24Ah@10 hour-rate | |
Dimension | Length | 165±2(6.49 inches) |
Width | 126±2(4.96 inches) | |
Height | 174±2(6.85 inches) | |
Total Height | 174±2(6.85 inches) | |
Weight | Approx. 7.6kg (17.2lbs) | |
Reference Capacity (25°C/77°F ) | 20 hour rate (1.3A) | 26Ah |
10 hour rate (2.4A) | 24Ah | |
5 hour rate (4.32A) | 21.6Ah | |
3 hour rate (6.4A) | 19.2Ah | |
1 hour rate (15.6A) | 15.6Ah | |
Max. Discharge Current (25°C/77°F) | 156A (5S) | |
Internal Resistance | Full charged at 25℃(77°F): Approx. 15mΩ | |
Charge (Constant Voltage) (25°C/77°F) | Cycle Use | Voltage: 14.4-15.0V Initial Charging Current: Less than 7.2A |
Float Use | Voltage: 13.6-13.8V | |
Operating Temperature Range | Discharge | -20~50°C |
Charge | 0~50°C | |
Storage | -20~50°C | |
Nominal Operating Temperature Range | 25°C ±3°C(77±3°F) | |
Capacity affected by Temperature (20 hour rate) | 40°C(104°F) | 102% |
25°C(77°F) | 100% | |
0°C(32°F) | 85% | |
-15°C(5°F) | 65% | |
Self-Discharge (25°C/77°F) | After 3 month | 91% |
After 6 month | 82% | |
After 12 month | 64% | |
Container Material | ABS Plastic |
-Electric Powered Vehicles -Golf Cars and Buggies
-Wheel Chairs -Power Tools
-Electric Powered Toys -Control System
-Medical Equipments -UPS Systems
-Solar and Wind -Emergency Systems