1350 Aluminum Duplex Service Drop Wire For Power Distribution

Country/Region china
City & Province luoyang henan
Categories Electronic Signs
InquireNow

Product Details

1350 Aluminum Duplex Service Drop Wire For Power Distribution

 

1. Construction

One insulated phase conductors twisted around a bare aluminum alloy or ACSR neutral conductor.

Conductors: Aluminum alloy 1350-H19 wire.

Insulation: Black thermoset cross-linked polyethylene (XLPE).

Neutral: Bare aluminum alloy or ACSR

2. Specification of Triplex Low Voltage Power Cable

Cable meets or exceeds the following ASTM specifications:
· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
· B-231 Aluminum Conductors, Concentric-Lay-Stranded.
· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire

 

3. Conductor:

Phase ConductorBare Neutral Messenger
AACAAC
ACSR
Alloy

 

4. Service Drop Cable Meets or Exceeds the Following Specifications:

1). Aluminum Wire,1350-H19 for Electrical Purposes;

2). Aluminum Conductors,Concentric-Lay-Stranded;

3). Aluminum Conductor,Concentric-Lay-Stranded,Coated Steel Reinforced(ACSR);

4). Concentric-Lay-Stranded 6201-T81 Conductors;

5). Service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474;

 

5. Cable's Characteristics:

1). Max.admissible long time operating to conductor:

PVC or PE insulated should not exceed 70℃,XLPE insulated should not exceed 90℃;

2). Installing temperature should not be below -20℃;

3). Admissible bending radius:

When overall-diameter(D)is less than 25mm,it should be not less than 4D;

When overall-diameter(D) is 25mm or more,it should be not less than 6D;

 

Triplex Service Drop

 

Code nameAWG or kcmilBare Neutral MessengerPhase ConductorWeightAllowable Ampacities(A)
ACSRRated Strength lbs.AACInsul.Thick.Mm
No.&Dia.MmNo.& Dia.MmNo. & Dia.Mmkg/kmXLPEPE
Paludina2*6AWG+1*6AWG1*1.686*1.6811901*4.111.141668570
Voluta2*6AWG+1*6AWG1*1.686*1.6811907*1.561.141708570
Whelk2*4AWG+1*4AWG1*2.126*2.1218601*5.191.1425111590
Periwinkle2*4AWG+1*4AWG1*2.126*2.1218607*1.961.1425511590
Conch2*2AWG+1*2AWG1*2.676*2.6728507*2.471.14389150120
Neritina2*1/0AWG+1*1/0AWG1*3.376*3.3743807*3.121.52624205160
Cenia2*1/0AWG+1*1/0AWG1*3.376*3.37438019*1.891.52625205160

 

Duplex Service Drop

Code wordAWG or kcmilBare Neutral MessengerPhase ConductorWeightAllowable Ampacities(A)
ALLOYRated Strength libs.A ACInsul.Thick.Mm
Number & Dia.MmNumber&Dia.Mmkg/kmXLPEPE
Chihuahua1*6AWG+1*30.587*1.6811101*4.111.14988570
Vizsla1*6AWG+1*30.587*1.6811107*1.561.141008570
Harrier1*4AWG+1*48.697*2.1217601*5.191.1414911590
Whippet1*4AWG+1*48.697*2.1217607*1.961.1415111590
Schnauzer1*2AWG+1*77.477*2.6728007*2.471.14231150120
Heeler1*1/0AWG+1*123.37*3.37446019*1.891.52372205160

 

Hot Products

795 Acsr Aluminum Conductor Steel Reinforced Acsr Drake Southwire​ Construction Aluminum 1350-H19 ...
Overhead Aluminium Conductor Cable Conductor Aaac 120 Mm2 35 Mm2​ Applications Conductor Aaac 120 ...
Aluminum Alloy 1350-H19 Bare ACSR Conductors Overhead Transmission Specifications These conductors ...
Overhead Aluminium Conductor Cable ACSR 1/0 2 AWG 1KV Bare ACSR conductors are intended for use as ...
ACSR Aluminium Conductor Cable Aluminum Conductor Reinforced With Steel For added strength, ACSR are ...
AAAC AAC ACAR Aluminum Conductor Alloy Reinforced Bare Conductor Wire Product Description 0.6/1kV ...