Home Companies Hangzhou AllTest Biotech CO.,LTD

CysC Test Cassette Easy Use By fluorescence Immunoassay Analyzer, Fluorescence Immunoassay Test

Hangzhou AllTest Biotech CO.,LTD

Contact Us

[China] country

Trade Verify

Address: #383, Qiaoxin Road, Xiasha Street, Qiantang Disctrict, Hangzhou, Zhejiang, P.R.China

Contact name:Selina

Inquir Now

Hangzhou AllTest Biotech CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CysC Test Cassette Easy Use By fluorescence Immunoassay Analyzer, Fluorescence Immunoassay Test

Country/Region china
City & Province hangzhou zhejiang
Categories Dyestuff Intermediates
InquireNow

Product Details

CysC Test Cassette Easy Use By fluorescence Immunoassay Analyzer, Fluorescence Immunoassay Test

 

The Cys-C Test Cassette is based on Fluorescence Immunoassay to measure Cys-C in whole blood or serum or plasma to aid in the diagnosis of Renal function.The test result is calculated by Fluorescence Immunoassay Analyzer.
 
Product Name:CysC Test Cassette Easy Use By Fluorescence Immunoassay Analyzer, Fluorescence Immunoassay Test
Format:Cassette
Certificate:CE
Pack:10T/25T
Shelf Life:2 Years
Linearity Range:0.1~9.0mg/l , R≥0.990
Principle:Fluorescence Immunoassay
Specimen:Urine
Reading Time:15 Minutes
Storage Temperature:4-30℃
Cut-Off:1.1mg/L
Analytical Sensitivity:The Cys-C Test Cassette Can Detect Levels Of Cys-C As Low As 0.1 Mg/l In Whole Blood,serum, Plasma.

 

 

Application And Description:

 

Cystatin C or cystatin 3 (formerly gamma trace, post-gamma-globulin, or neuroendocrine basic polypeptide), a protein encoded by the CST3 gene, is mainly used as a biomarker of kidney function.Cystatin C has a low molecular weight (approximately 13.3 kilodaltons), and it is removed from the bloodstream by glomerular filtration in the kidneys. If kidney function and glomerular filtration rate decline, the blood levels of cystatin C rise. Cross-sectional studies (based on a single point in time) suggest that serum levels of cystatin C are a more precise test of kidney function (as represented by the glomerular filtration rate, GFR) than serum creatinine levels.Longitudinal studies (following cystatin Cover time) are sparse, but some show promising results.Cystatin C levels are less dependent on age, gender, ethnicity and muscle mass compared to creatinine.

 

How to use?

 

Refer to Fiatest TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be in room temperature.
Allow the test cassette, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
1. Turn on the Analyzer power. Then according to the need, select “standard test” or “Quick test” mode.
2. Remove the ID card and insert it into the Analyzer port.
3. Pipette 20μL of specimen into the buffer tube, then mix thoroughly.
4. Pipette 75μL diluted sample into the sample well. Start the timer at the same time.
5. There are two test modes for Fiatest TM Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode. Please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyzer for details.
“Quick test” mode: After 10 minutes of adding sample,Insert the test cassette into the Analyzer and click "New test" immediately,The Analyzer will automatically give the test result after a few seconds.
“Standard test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click "New test" at the same time, The Analyzer will automatically countdown 10 minutes. After the countdown, the Analyzer will give the result at once.
 

INTERPRETATION OF RESULTS
Results read by Fiatest TM Fluorescence Immunoassay Analyzer.
The result of tests for Cystatin C is calculated by Fiatest TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyze.
Linearity range of Fiatest TM Cystatin C Test is 0.1-9 mg/L.

 

【PERFORMANCE CHARACTERISTICS】

1. Accuracy

The test deviation ≤±15%.

2. Analytical sensitivity

The Cys-C Test Cassette can detect levels of Cys-C as low as 0.1 mg/l in whole blood,serum, plasma.

3. Linear range

0.1~9.0mg/l , R≥0.990

4. Precision

 C.V.  ≤ 15%.

 

   

    Fast Result (10 minutes)

    Simple Operation (Less Training Required)

    Objective (Results Read by Analyzer)

    Stringent Quality Control Insure High Accuracy

    User-friendly (Simple Plug & Play Operation)

    High Efficiency (Both STAT Testing and Batch Testing)

 
Catalogue NumberItem NameSampleTest RangeKIT size
FI-CYSC-402CysC Test CassetteWB/S/P0.1-9 mg/L10T/25T

Hot Products

Canine Distemper Virus and Canine Adenovirus-II Antigen combo Rapid Test Kit, Cat Rapid Test Product ...
CDV+CAV-II+CIV Antigen Combo Rapid Test Cassette (Secretions), Canine Distemper Virus Antigen ...
CHW Antigen+ Ehrlichia Antibody+ Lyme IgG/IgM Antibody Combo Rapid Test Cassette (Whole Blood/Serum...
CHW Antigen+ Ehrlichia Antibody+ Lyme IgG/IgM Antibody Combo Rapid Test Cassette (Whole Blood/Serum...
Product Name: Canine Distemper Virus + Canine Adenovirus-II Antigen Combo Rapid Test Cassette ...
CDV+CAV-II+CIV Antigen Combo Rapid Test Cassette (Secretions) , Ocular And Nasal Secretions CDV+CAV...