Product Description of FFU
FFU is air cleaning equipment to supply purified air to the clean
room for manufacturing semiconductor, liquid crystal, etc.
The installation space is the system ceiling grid. For a large
clean room, the number of required FFU is from several hundreds to
several thousands.
Advantages of FFU
1. Simple direct speed control.
2. Low power consumption.
3. Low sound power level.
4. EC Fan with high reserve capacity for pre- and AMC filtration.
5. Very low design height.
6. The degree of cleanness from class 10 to class 1000 can be set
and the degree of cleanness can be set at each area.
Application of FFU
Flexible and economical modular solution to equip turbulent clean
rooms from ISO 8 to ISO 1 with very low space above the false
ceiling.
Semiconductor, electronics, flat-panel displays, disc-drive,
manufacturers and optics, bio-engineering, clean lines, clean
bench, clean room ,laminar flow hood ,etc.
Company Information
Our factory with competitive price
Automatic production line.
Nearly 20 years experience in cleanroom industry.
We are an expert in providing customized solutions.
Timely delivery with perfect quality.
Fortune 500 companies’ choice.
Have passed ISO9001.2008 certification.
Specifications:
MODEL | KEL-FFU615 | KEL-FFU920 | KEL-FFU1175 | KEL-FFU1225 | |
External size (mm) (WXDXH) | 615X615X350 | 920x615x350 | 1175x575x350 | 1225X615X350 | |
Material | Steel plate with painting/galvanized steel/aluminum/stainless steel | ||||
Air flow(m3/h) | 600 | 800 | 1000 | 1200 | |
Air velocity (m/s) | 0.3/0.35/0.4/0.45/0.5 | ||||
Pressure(pa) | 97(10mmAq) | ||||
Control system | 1: Power on/off 2: Control air speed up/down | ||||
HEPA FILTER | Size(mm) | 610X610X69 | 915X610X69 | 1170x570x69 | 1220x610x69 |
Efficiency(%) | 99.995% @ 0.3um | ||||
Pressure (pa) | <220pa @ 0.45m/s | ||||
Power supply | 220V/110V ,50/60HZ | ||||
Power (w) | 115w | 115w | 123w | 172w | |
Noise (Db) | 57 | 57 | 57 | 57 |
Our Service:
1: Document
A: Document for custom clear: 1 sets
B: Assemble draw: 1 pcs
C: Circuit diagram draw: 1 pcs
D: Test report : 1sets
E: Additional IQ/OQ/PQ document is available upon request.
2: the follow spare part so that you can replacement in future by
yourself:
A: HEPA air filter +Pre-filter (as your request)
Note: HEPA air filter should be replacement in half and one year.
Pre-filter
should be replacement in each 6 months, but it can refresh no more
than 3 times
B: Sensor (As your request)
C: Control board (as your request)