Features of most efficient underfloor heating air source heat pump air conditioning energy saving heat pump

A heat pump is an energy-saving device that uses high-level energy to flow heat from a low-level heat source to a high-level heat source. As the low-level heat source of the heat pump, air is inexhaustible and inexhaustible. It is available everywhere and can be obtained free of charge. Moreover, the installation and use of air source heat pumps are relatively convenient. The research, production, and application of air source heat pumps (also known as air-cooled heat pumps) in my country only developed rapidly in the late 1980s. The current products include household heat pump air conditioners, commercial unit heat pump air conditioners and heat pump cold and hot water units.
The air source heat pump has the following characteristics:

most efficient underfloor heating air source heat pump air conditioning energy saving heat pump
(1) The air energy heat pump system integrates cold and heat sources, no special refrigerating machine room or boiler room is required, the unit can be placed on the roof or the ground arbitrarily, and it does not occupy the effective use area of ​​the building, and the construction and installation are very simple.
(2) The air energy heat pump system has no cooling water system, no cooling water consumption, and no cooling water system power consumption. In addition, many cases of Legionella infection caused by cooling water pollution have been reported. From the perspective of safety and health, considering air source heat pumps also has obvious advantages.
(3) The air-energy heat pump heating system does not require a boiler, a corresponding boiler fuel supply system, a dust removal system, and a flue gas discharge system, so the system is safe and reliable, and does not pollute the environment.
(4) The air-energy heat pump cold (hot) water unit adopts a modular design, and there is no need to set up a standby unit. The computer automatically controls during operation to adjust the operation status of the unit to adapt the output power to the working environment.
(5) The performance of the air-energy heat pump will vary with outdoor climate changes.

For further specification of Inverter 10HP 36.7 KW Split Heat Pump For Swimming Pool Use and other specifications, welcome to contact us!

most efficient underfloor heating air source heat pump air conditioning energy saving heat pump

 

Unit typeSJKRS-36II/C
Specifications10HP
Power supplyThree-phase five-wire380V/50Hz
Heating modeDirect heat/cycle type
Standard working conditionHeating capacity( kw )36.7
Input Power(kW)8.2
COP4.5
Hot Water flow(m³/h)0.79
High temperature conditionHeating capacity kw )28.5
Input Power(kW)8.9
COP3.2
Hot Water flow(m³/h)0.33
Low temperature conditionHeating capacity( kw )21.4
Input Power(kW)7.6
COP2.8
Hot Water flow(m³/h)0.4
Component InformationSize of water pipe jointDN20
Water heat exchangerPlate or sleeve heat exchanger
Air Heat ExchangerAluminum Fin for copper tube
compressor typeSemi-closed reciprocating
Operation PanelColor touch screen
Maximum outlet temperature(℃)90℃
RefrigerantsR744 (CO2 )
Design pressure(MPa)High side 15, low side 8
Dimensions (length, width and height mm)1600x950x1500
Noise (dB)59
Weight(kg)660
SCOPE of useFeed water temperature(℃)5~ 40
Feed water pressure0.05~ 0.4
Effluent temperature(℃)55~ 90
Maximum flow1.5
Ambient temperature(℃)’-20~43

 

1) standard working conditions: ambient temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 55 ° c;

2) high temperature effluent: Ambient Temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 90 ° c;

3) low temperature working condition: ambient temperature DB-10 °C, using side initial water temperature 9 °C, termination water temperature 55 °c;

Some projects for 10HP 36.7 KW Split Heat Pump For Swimming Pool

Hot Products

Application of Air Source Heat Pump swimming pool heater and cooling indoor and outside DC inverter ...
Strength of most efficient Swimming Pool Heat Pumps Low Carbon Route to Warm Water STEPLESS DC ...
Strength of Pump Air Heat Heating Pump Air To Water NE-B245/100E Dc Inverter Heat Pump Advanced ...
Strength of R410A Bomba de Calor Air Source Pool Heater Full Inverter Heat Pump (1) The air source ...
Strength of 2020 New EVI Heat Pump Commercial Air to Water Heater 3kw Air To Water Source Mini ...
Strength of R410A Apartment Air Source Heater Hot Water Air to Water DC Inverter Heat Pump 6~250KW ...