Henan Lantian Medical Supplies Co.,Ltd. |
|
Type I is needle tube protective sheath; A flexible venous blood collection needle comprises a blood collection needle tube, a needle handle (single wing or double wing), a tube, a needle cover, a cork puncture needle and a puncture needle protection. Type II straight needle vein The Lancet consists of puncture needle shell, puncture needle protective sleeve, cork puncture needle, needle seat, willow tube and needle tube protective sleeve.
Matching disposable venous blood sample collection container is used to collect blood samples from human vein.
1. Attach the tourniquet to the shoulders and elbows with proper
flexibility. (The tourniquet is too loose, the pressure is not
enough, and the tourniquet is too tight or too low, which cannot
cause hematoma at the puncture site).
2.Disinfect the skin from inside to outside of the puncture site.
3.Choose a suitable disposable venous blood collection needle, dry
the disinfectant naturally, fix the upper arm of the patient with
the left hand, and quickly insert the needle into the slope of
15-30. Place the blood collection needle on the side of the blood
collection vessel. If there is a rubber plug on the test tube due
to the negative pressure of the blood collection tube, the blood
will automatically flow to the blood collection tube. Please
collect blood in the following order: red tube (yellow tube), blue
tube, black tube, green tube, purple tube and grey tube, so as to
avoid affecting the test results.
4.After blood collection, pull out the blood collection tube,
gently press the blood collection point with a cotton swab or
cotton swab, quickly pull out the needle, and press for 10 minutes
until the patient has no bleeding. Quickly turn over the bleeding
test tube containing additives and stir evenly for 5~6 times (try
in reverse, please stir as soon as possible when drawing blood)
5.Put the used disposable venous blood collection needle into a
special recovery device.
1. This product contains disposable plasticizer DEHP. The
sterilization method is ethephon hydroxyl sterilization. The
product is valid for 2 years. It is forbidden to use if the package
is torn or exceeds the validity period.
2.The use of products must conform to the requirements of the
relevant operational specifications and relevant laws and
regulations of the medical department.
3.Under normal circumstances, redness, swelling and other
undesirable phenomena will not occur during use. If these phenomena
are found, please consult a doctor for timely treatment.
4.This product is for professional medical staff. Do not use cork
puncture needle more than 5 times.
5.After use, do not accidentally discard the venous blood
collection needle, and put it in a special recovery device.
6.When using venous blood collection needles, always be careful not
to accidentally hurt yourself or others.
7.The tundish is 100 PC/ package.
Non-corrosive gas, stored in cool, dry and ventilated clean environment.