Henan Lantian Medical Supplies Co.,Ltd. |
|
Disposable vacuum blood collection container consists of test tube, stopper, cover, label and additive (if any) and additive (if any)
Sodium citrate 9:1, sodium citrate 4:1, heparin sodium, heparin lithium, heparin lithium / separation gel, accelerator / separation gel, accelerator, EDTAK2, heparin sodium / sodium fluoride, EDTAK2 / separation gel, edtak3, edtak3 / separation gel, heparin sodium / separation gel, without additives
Combined with disposable venous blood sampling needle, it is used for collection, transportation and storage of human venous blood
select the right type of blood collection vessel according to the daily test purpose | ||
Types of additives | Additive code | Recommended colors |
No additives | Z | red |
Accelerator | None | Red/orange |
Separation gel / accelerator | None | yellow |
Heparin lithium | LH | green |
Heparin sodium | NH | green |
Heparin lithium / separation gel | None | green |
Edtak3 / separator | None | violet |
Heparin sodium / separation gel | None | green |
EDTAK2 / separator | None | violet |
Sodium citrate 9:1 | 9NC | wathet |
Sodium fluoride / heparin sodium | FH | grey |
EDTAK2 | K2E | violet |
EDTAK3 | K3E | violet |
Sodium citrate 4:1 | 4NC | black |
1. The arm of the sampled person is downward, the venipuncture
position is selected, the blood sampling belt is applied, and the
venipuncture position is disinfected;
2. Screw down the sheath of the blood sampling needle, and carry
out venipuncture under the condition that the arm is downward and
the cap of the collecting tube is upward;
3. The other end penetrates the diaphragm of the rubber plug to
prevent side penetration and premature loss of negative pressure.
4. Once the blood enters the blood collection vessel, release the
blood collection belt immediately. After the collection, draw the
blood collection needle out of the vein and use the disinfection
product to compress the puncture position to stop bleeding.
5. After blood collection, the blood collection vessel was turned
upside down and shaken up for 5 times; Place it for observation.
6. The disposable vacuum blood collection container after use is
placed in a special recycling appliance.
Store in a dry, well ventilated and clean warehouse with relative humidity less than 80% and no corrosive gas
1. This product is disposable product;
2. If the pipe body is damaged or the plug is loose, it is
forbidden to use;
3. The vacuum blood vessels containing anticoagulants should be
mixed 5-8 times after blood collection to ensure the complete
fusion of anticoagulant and blood samples;
4. The blood vessels containing coagulant or separating glue were
placed upright after blood collection, and then centrifuged after
the blood was completely solidified;
5. Please use special vacuum vessels for high altitude area;
6. The product shall be used in accordance with the relevant
operation specifications of medical department, and shall be
limited to the use of trained medical personnel.