Fixed Type Innovating Aerosol Extinguishing Systems Eco-friendly Clean Agent

 

Brief requirements of Aerosol Extinguishing Systems according to GA499.1-2010

  • Spray process and state-fire extinguishing device should be able to spray normally after switching on the start signal
  • During discharge, there shall be no open fire or spark at the nozzle, and no residue shall overflow during or after injection
  • After the completion of spraying, the shell shall not be deformed, burnt through or ignited on the surface of the shell.
  • The total filling mass of aerosol generator in a fire extinguishing device shall not be more than 10kg, and the deviation of filling mass shall not exceed 2% of its nominal mass.
  • The operating voltage of the electric initiator shall not be greater than 24 vd.c.
  • The raw materials used to produce aerosol generating agents should be non-toxic to organisms and the combustion products do not contain harmful ingredients that damage the atmospheric ozone layer.

 

Fireless 125 technical parameter:

ItemSpecification
Overall dimensions(mm)240( diameter)X126(height)
Extinguishing device weight(Kg)6.8
Agent quantity(Kg)3.5
Protected volume(m³)125
Working temperature(℃)-50℃~+95℃
Safety current(mA,DC)≤150mA
Discharge times)≤ 19
Service life(year)10

 

FAQ for technical terms

  • Do the protected area needed 100% closed?

Answer: no, it doesn’t .

  • what is ratio of open area to total area in enclosure?

Answer:Represents the unsealing degree of the enclosed space, and its value is the ratio of the unclosed open area in the enclosed space to the total surface area, expressed as a percentage.

  • What is flame extinguishing density?

Answer:The mass of an aerosol agent required to extinguish a fire in unit volume, g/m³.

  • What is discharge delay time?

Answer:The time when the fire extinguishing device receives the starting signal and the nozzle begins to spew hot gas sol extinguishing agent.

  • What is discharging time?

Answer:The time from the beginning discharging aerosol to discharging stopped.

  • What is outlet temperature in discharging?

Answer:During the process of discharge heat aerosol fire extinguishing agent, the outlet temperature is where 5 meters away from nozzle.

  • Is there any cooling equipment in the generator?

Answer:Yes, it’s medium or device installed in a fire extinguishing device to effectively reduce the temperature of a hot gas aerosol extinguishing agent before it passes through the nozzle.

 

Application:

data centers/ UPS/ ESP/ museums/ warehouses/ electric cabinets/ generator rooms panels/ engine rooms/ different transportation vehicles

Hot Products

Aerosol Fire Extinguishing System Aerosol Fire Suppression Generators Provide Characteristics of ...
Aerosol Fire Extinguishing System For Low-voltage Power Distribution Cabinets The reasons of ...
Updated Fixed Small Size Aerosol Fire Extinguishing System Cost Effective Quick details 1. Small and ...
Automatic Aerosol Fire Extinguishing System With IP65 Water Proof Product information FireLess 1.0A ...
Fixed Type Innovating Aerosol Extinguishing Systems Eco-friendly Clean Agent Brief requirements of ...
Fixed Latest Generation Aerosol Fire Extinguishing Systems For Battary Fires What is FireLess 0.3 ...