AMC16-DETT Base Station DC Energy Meter

● DC rated voltage: 1 channel: -48VDC
● Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%
● RS485(MODBUS-RTU)
● LED display
● DIN 35 mm

Dimensions(mm)

 

Function&Parameter

 

InputDC voltage1 channel: -48VDC
DC current6 channel hall current sensor,total DC200A/5V,China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V.
Grid power monitoring1 channel: 0-5VDC
Overload capacityVoltage: 1.2times continued,2 times continued 1s; Current: 1.2 times continued, 10 times continued 1s.
Accuracy (superposition hall sensors)1%ln^10%ln error±2.5%; l>10%ln error±2%
resolutionVoltage output accuracy 0.01V: current output accuracy 0.01A; power output accuracy 0.01 kw; energy output accuracy 0.01 kwh
FunctionsBasic functionMonitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED indicator display;485 communication
Metering functionStart current: under rated voltage, when the load current value of the meter doesn t exceed 1% of the max. current, the meter starts. Shunt running current: when there is no current in the current circuit of the meter and 85%-125%of the rated voltage is applied on the voltage circuit the calculator shall not have more than
Alarm functionDC low voltage output alarm,DC high voltage output alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm, memory failure alarm and AC input power failure alarm
Timing functionsupport broadcast timing, could remote timing to the meter by RS485
Hall CT power supply:Power supply output:+12V/100Ma, -12V/50mA
Clock accuracyM0.5s/d (23°C) , Mls/d (-20°C~60°C)
Powe supply for ther meter-40VDC- -60VDC
Power consumptionM2W

Appearance

Wiring

Hot Products

ARD2F Motor Leakage Protection Motor Unbalance Protection motor protection controller ARD2F ...
Acrel ARD2F digital motor protection relay 3 phase motor overload protection Acrel ARD2F digital ...
Acrel ARD2F digital motor protection relay 3 phase motor overload protection The ARD series of ...
ARD2F Series Smart Motor Protection Relay The ARD2F intelligent motor protector (hereinafter ...
ARD2F Series Smart Motor Protection Relay The ARD2F intelligent motor protector (hereinafter ...