High temperature control valves,auto zone valve for central heating system valve

 

Product description

The temperature regulating valve systems, are for water and steam commonly used in heating / cooling supply systems. These systems include a temperature control valve with an internal ball check valve to be opened or closed by manually or electric actuator motor. The ball valves for control of the water supply, and a digital thermostat that displays the outlet temperature.

 

Functions

  • Wireless temperature control valve is divided into wireless temperature controller and smart valve, controller including motor drive and wireless communication part
  • The controller senses the environment temperature, and the valve and the thermostat are transmitted by wireless communication module, so that the installation is convenient and the construction is simple
  • The controller open and close the valve according to the environment temperature
  • Smart valve can transmitted through MBus wires to the collector to control the valve open/close, to achieve the purpose of indoor thermostat
  • Real-time display the indoor temperature, open/close state and the default prompt function

Controller

  • Power:2* AAA batteries;
  • Wireless radio frequency: 430 ~ 434MHz;
  • Wireless transmission distance ≥ 200m (open area);
  • Range of temperature setting : 4 °C ~ 50 °C;
  • Range of the induction temperature range: 0 ° C ~ 70 ° C;
  • The accuracy of sensor : ± 0.5 ° C;
  • Setting of Beijing time;
  • Setting of the required temperature;
  • The "ON-OFF" on controller is means that to open or close the the temperature judgments of the controller, not equal to open and close the valve;
  • The “OFF” on controller is means that to close temperature control function (equivalent to set the temperature of 99 ℃), the actually implement to “Opening” command and keep the valve to open position;
  • The controller received the wireless synchronization signal and update the latest control state per 3 minute;
  • The controller and the control module inside valves is one to one, real-time and re-code;

Technical introduction

  • Work voltage:DC12V or DC24V
  • Wireless radio frequency: 430 ~ 434MHz;
  • The current temperature is lower than the set temperature (set temperature :-1), then the inside wireless control module implement command of” Opening” and the valve be open;
  • The current temperature is higher than the set temperature (set temperature :+1), then the inside wireless control module implement command of” Closing” and the valve be closed;
  • The valve keep open position when power-off;
  • The valve will keep open position as soon as the controller is more than 10 min without receiving the remote control of the wireless synchronization signal;
  • The controller update to detect the current temperature per 3 secs;
  • The controller just power -on without remote control, the valve keep opening position;

Our advantages

  • More than 50 types, diameter ranges from DN15 to DN40, it features small torque, low electricity consumption,leak-proof, high pressure rating.
  • Customized production available, thanks to our strong mechanical machining and milling capability
  • Sturday valve body with reasonable structure design, and best material to be used
NoNameMaterialAdvantage
1.O-ring

Import

fluoro rubber (green)

Resistance to high temperature, oil, corrosion, chemicals, Work temp.: —30℃+280℃.Quadruple seals, minimize the risk of leakage.
2.Drainage Drain just in case leakage happens
40-ringEPDM (red)Between nut and valve body, extra external leak proof, reduce the possibility of internal leak
8.BallBrass or SS304Finely polished, rack nickel plating (not barrel plating), smooth surface, improved torque performance
9.Water proof G Avoid water into housing, seal between valve body and valve housing
NoNameMaterialAdvantages
5.Wall thickness 2.0mm, PN20
6.Teflon washerImport teflon

1. Import teflon tube, numerical processing to perfectly match with ball surface

2. Minimal deformation, polish surface, wearable

70-ringEPDM

1. Good elasticity, as buffer after Teflon washer to improve seal effect

2. Reasonable structure design, ensures perfect holding margin

    

 

Product dimensions

Valve body materialConnection portDiameterDLHW
(mm)(Kg)
brassBoth female thread full diameterDN202099550.508
DN2525110600.668

 

Wiring (DC24V)

 

Applications range

  • HVAC, heating supply systems
  • Air conditioning systems
  • Baseboard/radiant heating
  • Convectors
  • Fan coil units
  • Floor heating
  • Unit ventilators
  • VAV reheat

Hot Products

flange Electromagnetic Water Flow Meter, Thermal Mass Flow Meter working principle Description Newly ...
Electromagnetic Water Flow Meter, thermal mass flow meter, heat meter electrode 316L Description Our ...
Electromagnetic Water Flow Meter, seawater magnetic flow transmitter, heat meter Description The ...
mass flow meter for slurry, Electromagnetic Water Flow Meter electrode:316L, Liner: PTFE Description ...
Wireless Electromagnetic Water Flow Meter, slurry flow measurement liner:Rubber,316L Description Our ...
6inch electromagnetic water flow meter, rosemount slurry magnetic flow meter PN16Mpa Description The ...