6-points Chemiluminescence Calibrator Kit for POCT Analyzer POClia with 8 Channels

 

product compositionSix points: ABCDEF
Testing method1. Treat the calibrator as the sample to be tested, and place it in the sample loading area of the instrument after mixing. Note that when mixing Avoid air bubbles.
2. During the detection, the system detects the luminescence value (RLU value) of each calibration point, and calculates the luminescence value according to the nominal concentration and luminescence value.
The calibration curve is automatically fitted by the instrument. In order to ensure the reliability of the calibration curve, the determination of the calibrator should be
Make a double.
3. The generated calibration curve can be used for 28 days, but it should be re-calibrated after the following conditions:
① Change of batch number of supporting testing reagents;
Change of batch number of luminescent substrate
②The measured value of the quality control product is not within the scope of quality control or the test results are inconsistent with the clinical situation;
③System for major repairs or maintenance.
Interpretation of test results1. For reasons such as methodology or antibody specificity, the same sample was tested using reagents from different manufacturers.
Testing with different reagents may give different test results, therefore, the results obtained by testing with different reagents should not be directly
They are compared with each other in order to avoid false medical interpretations.
2. The quality control product can be used as a reference for the reliability of the current experimental results, and its measured value should be within the
within the range allowed by the quality control sheet. Test results should be based on reference value ranges and other clinical factors and results
Comprehensive judgment, when the test result is close to the upper limit or lower limit of the reference value range, it can be considered
samples for confirmation testing.
Storage and expiration dateStored at 2-8°C, the product is valid for 12 months. Reagents should be used within 1 month after opening, and stored at 2-8°C away from direct sunlight.

 

Hot Products

pet animal detection analyzer monotest single reagent strip With cat dog serum/heparin anticoagulate...
IVD Pet animal cat detection reagent single test monotest Total Thyroxine T4 In Thyroid Clinical ...
IVD Pet animal dog detection reagent single test monotest Total Thyroxine T4 In Thyroid Clinical ...
AFP/F-hCGβ/FE3/PAPP-A Calibrator for Automatic Immunoassay Analyzer A calibrator is a reference ...
Torch HSV-1IgG/HSV-1 IgM/HSV-2 IgG/HSV-2 IgM Calibrator for Automatic Immunoassay Analyzer A ...
Torch Toxo IgM/Toxo IgG/Rubella IgM/Rubella IgG/CMV IgG/CMV IgM Calibrator for Automatic Immunoassay ...