             magnetic flow meter used for waste water system

Product show                                                                                                                   


 

 

Parameters                                                                                                                    

Aperture

10-3200

Excitation System

Bidirectional Constant Flow Squarewave Excitation

Installation Form

Integral or split

Lining

Chloroprene Rubber,PTFE

Material of Electrode

316L,HC,HB,Titanium,Tantalum,Platiniridium

Grounding

Built-in Grounding Electrode

Medium

Conductive Liquid

Grade of Accuracy

0.3 ,0.5,  1.0

Flow Velocity

≤15m/s

Flange of Pipe 

Connection

GB9119-2000 or GB9115-2000

Pipe connection

Flange Connection

Temperature of Medium

Chloroprene Rubber:-10-60℃: PTFE:-10-120℃

Rated Boltage

1.0MPa,  1.6MPa,  4MPa

Cable Interface

G1/2 Female Thread

Category of 

Shielding

IP65, IP68

Output Signal

4-20mACurrent,Pulse, Warning beyond upper and lower limits

Communication

RS485 Protocol

Display of Monitor

Transient Flow,Percentage,Flow Velocity,Forward and Reverse Integrated 

Flux and Total Integrated Flux

Power Supply

220VAC, 24VDC

Type of Application

General Type, Waterproof Type

 

  Iining                                                                                                                              

 

lining

Main performance

Scope of application

F4(PTFE) 

polytetrafluoroet

hylene

A plastic and chemical properties of the most stable, 

capable of boiling hydrochloric acid, sulfuric acid, nitric 

acid, and concentrated alkali and organic solvents. Not

 resistant to three chlorine fluoride, high temperature, high 

velocity fluid three chlorine trifluoride fluorine, oxygen, corrosion

Concentrated acid and

 other strong corrosive

 medium, medium health

 class

Chloroprene

 rubber

The elastic properties, tensile strength, wear resistance, 

corrosion resistance, low concentration of acid, alkali, 

salt, corrosion resistance and oxidation medium

Water, sewage, low wear 

of mud slurry

Polyurethane 

rubber

Strong wear resistance, corrosion resistance is poor

The slurry, coal slurry, 

slurry neutral strong wear

 

Installation                                                                                                                     

 

 

Conventional caliber flow range( Large caliber Advisory )                                        

 

 

Outline dimension                                                                                                          

 

 

Application area                                                                                                           

1. Drinking water supply, water supply, reservoir and pumping station etc.

2. Chemical acid, lye, conductive solution, cooling fluid, additives etc.

3. Drink water, beer, wine, alcohol, milk, yogurt, fruit juice, syrup, blood etc.

4. Refrigeration / air conditioning and refrigeration thermal measurement, or heat energy.

5. Sewage, industrial sewage discharge, sewage etc.

6.Control of metal industrial pump,cooling water and the flow of water.

7. The textile industry of water, pigments, chemicals, bleaching chemicals etc.

  Order sheet                                                                                                                   

Name

Specification code

Explanation

Instrument type

 

Intelligent  flow meter

Diameter code

xxx

For example:100 represents DN100

Electrode form

1

Standard stationary type

 

 

 

 

Electrode material

0

Stainless steel(316L)

1

Platinum Pt

2

Hastelloy B(HB)

3

Tantalum Ta

4

Titanium Ti

5

Hastelloy C(HC)

 

 

 

Lining material

3

Chloroprene rubber

4

Polyurethane rubber

5

F4(PTFE) polytetrafluoroethylene

6

F46(FEP)polyperfluoroethylene-propylene

 

 

 

Rated pressure(MPa)

4.0

DN10-80

1.6

DN100-150

1.0

DN200-1000

0.6

DN1100-2000

0.25

DN2200

 

Operating temperature

E

<80℃

H

<120℃

Grounding

 

Built-in grounding electrode

Grade of  protection

0

IP65

1

IP68

Converter type

0

Integral type

1

Split type

Case material

0

Carbon steel

1

Stainless steel

Instrument flange

0

Carbon steel

1

Stainless steel

Installing timing flange

0

Withou

1

With

Power supply source

0

220VAC

1

24VDC

Instrument range

xxx

For example:(200)represents maximum 

fux corresponding to 20mA

Flow :200mm³/h

 

 

 

 

 

Contact me:

 

Hot Products

Differential pressure transmitter Metal Capacitive Sensor with low price Metal Capacitive Sensor ...
Liquid level transmitter/ pressure transmitter/ differential pressure transmitter/ pressure gauge ...
Capacitance pressure sensor Product description: The medium pressure is transferred to the test ...
Compensated OEM Pressure Sensors With Low Price Product description: The medium pressure is ...
Capplication metal capacitor pressure sensor Product description: The medium pressure is transferred ...
Capplication metal capacitor pressure sensor Product description: The medium pressure is transferred ...