Zhengzhou Yifang Cable Co., Ltd |
|
12×2×1.5 Insulated, underground cables , Flame retardant, armoured, PVC oversheathed, instrument cable
Application
instrumentation cables ensure the reliable performance and monitoring of machinery and equipment which are critical to the operations of industrial plants and manufacturing facilities, or oilfield,oil refinery project,automation and process control.
Standard
The major national standards according to which we manufacture our instrumentation cables are as below:
British | BS5308 Part 1 and Part 2 Cables |
British / European | BS EN 50288-7 Cables |
Structure
Solid Copper conductor/PE insulation/PE inner sheath/SWA armoured/PVC outer sheath
Also with IS and OS screen.
TECHNICAL DATA SHEET OF INSTRUMENT CABLE- Multi Pairs ,PE Insulated,Individual&Overall Screened,SWA armoured,PVC Outer Sheath | |||
ITEM | DESCRIPTION | UNIT | DATA |
1 | Type | mm2 | 12×2×1.5 |
2 | Reference standard | -- | BS 5308 |
3 | Conductor | ||
Conductor Material | -- | Solid copper conductor | |
Conductor Cross-sectional Area | mm2 | 1.5 | |
Stranding Number | No. | 1 | |
Approx. Round Conductor Diameter | mm | 1.38 | |
Max.Conductor D.C. Resistance at 20℃ | Ω/KM | 12.1 | |
4 | Insulation | ||
Material | -- | PE | |
Nominal thickness | mm | 0.6 | |
5 | Individual Screen | -- | Aluminum/polyester tape with a 7 strand 0.5mm2 sized tinned annealed Copper drain wire |
6 | Overall Screen | -- | Aluminum/polyester tape with a 7 strand 0.5mm2 sized tinned annealed Copper drain wire |
7 | Inner sheath | ||
Material | -- | PE | |
Nominal Thickness | mm | 1.2 | |
8 | Armour layer | ||
Material of armour | -- | Galvanized Steel Wire | |
Nominal diameter of steel wire | mm | 1.6 | |
9 | Outer sheath | ||
Material | -- | Flame Retartant PVC | |
Nominal thickness | mm | 1.8 | |
10 | Approx Overall diameter | mm | 30.3 |
11 | Approx. Weight | kg/km | 1639 |
We supply a wide range of instrumentation cables suitable for an even wider range of applications across industries
The sizes have produced are as below:
12× 2× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
6× 3× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
1× 2× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
1× 3× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
2× 3× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
2× 2× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
4× 2× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
6× 2× 1.5 Insulated, underground cables, instrument cable , Flame retardant, |
Packing and loading