Steel Supported Core Linnet 198.38SQMM ACSR Core Wire

Country/Region china
City & Province zhengzhou henan
Categories Power Cables
InquireNow

Product Details

Aluminum Conductor Steel-Supported Core Bare Conductor Linnet 198.38SQMM

 

APPLICATION

ACSR conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables.

 

STANDARD

Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards

 

TECHNICAL DATA

Numbers of WiresModules of ElasticityCoeficient of linear Expansion
ALSTEELKg/mm2Lb/in21/Cº1/Fº
618111.5 x10619.1 x10-610.6 x10-6
677711.0 x10619.8 x10-611.0 x10-6
12710715.2 x10615.3 x10-68.5 x10-6
181679.5 x10621.2 x10-611.8 x10-6
2477410.5 x10619.6 x10-610.9 x10-6
2677710.9 x10618.9 x10-610.5 x10-6
2877911.2 x10618.4 x10-610.2 x10-6
3078211.6 x10617.8 x10-69.9 x10-6
30198011.4 x10618.0 x10-610.0 x10-6
32198211.7 x10617.5 x10-69.7 x10-6
547709.9 x10619.3 x10-610.7 x10-6
5419689.7 x10619.4 x10-610.8 x10-6

 

CONSTRUCTION PARAMETERS

• IEC 60189

CodeNominal AreaStrandingOverall DiameterWeightBreaking LoadElectrical Resistance @20°Current Rating*
 ALSTEELTOTALALSTEEL     
 mm2mm2mm2No.xmmNo.xmmmmKg/KmKNΩ/KmA
16162.6718.76/1.841/1.845.5264.66.081.793485
25254.1729.26/2.301/2.306.9100.99.131.1478112
40406.6746.76/2.911/2.918.73161.514.40.7174150
636310.573.56/3.661/3.6610.98254.421.630.4555198
10010016.71176/4.611/4.6113.83403.834.330.2869263
1251256.9413218/2.971/2.9714.85397.929.170.2304299
12512520.414526/2.477/1.9215.64503.945.690.231302
1601608.8916918/3.361/3.3616.8509.336.180.18347
16016026.118626/2.807/2.1817.74644.957.690.1805351
20020011.121118/3.761/3.7618.8636.744.220.144398
20020032.623326/3.137/2.4319.81806.270.130.1444402
25025024.627522/3.807/2.1121.53880.668.720.1154458
25025040.729126/3.507/2.7222.161007.787.670.1155461
31531521.833745/2.997/1.9923.911039.679.030.0917526
31531551.336626/3.937/3.0524.871269.7106.830.0917530
40040027.742845/3.367/2.2426.881320.198.360.0722607
40040051.945254/3.077/3.0727.631510.3123.040.0723610
45045031.148145/3.577/2.3828.561485.2107.470.0642651
45045058.350854/3.267/3.2629.341699.1138.420.0643655
50050034.653545/3.767/2.5130.091650.2119.410.0578693
50050064.856554/3.437/3.4330.871887.9153.80.0578697
56056038.759945/3.987/2.6531.831848.2133.740.0516741
560*56070.963154/3.6319/2.1832.682103.4172.590.0516745
63063043.667445/4.227/2.8133.752079.2150.450.0459794
630*63079.871054/3.8519/2.3134.652366.3191.770.0459798
71071049.175945/4.487/2.9935.852343.2169.560.0407851
710*71089.980054/4.0919/2.4536.792666.8216.120.0407856
800*80034.683572/3.767/2.5137.612480.2167.410.0361910
800*80066.786784/3.487/3.4838.282732.7205.330.0362912
800*80010190154/4.3419/2.6139.093004.9243.520.0362916
900*90038.993972/3.997/2.6639.92790.2188.330.0321972
900*9007597584/3.697/3.6940.593074.2226.50.0322974
1000*100043.2104372/4.217/2.8042.083100.3209.260.02891031
1120*112047.3116772/4.4519/1.7844.53464.9234.530.02581096
1120*112091.2121184/4.1219/2.4745.313811.5283.170.02581100
1250*1250102135284/4.3519/2.6147.854253.9316.040.02321165
1250*125052.8130372/4.7019/1.88473867.1261.750.02311163
1120*112091.2121184/4.1219/2.4745.313811.5283.170.02581100

 

CONSTRUCTION

ACSR 120/20 conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.

By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.

     

   

 

 Why you choose us?

  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;

 

Hot Products

IEC605021 standard LV 1-5 cores XLPE armoured power cable Application: (1) Rated voltage is 0.6/1 KV ...
IEC60521 standard LV 1-5 Cores XLPE STA armoured LSZH power cable Structure Conductor: Copper ...
IEC60521 standard LV 1-5 Cores XLPE SWA armoured LSZH power cable Structure Conductor: Copper ...
LV Single Multi Core Power Cable IEC Standard CU/XLPE/PVC 150SQMM Structure Conductor: Copper ...
1kv multi core power cable 4x16sqmm cu/xlpe/pvc Application: 1kv multi core power cable 4x16sqmm cu...
IEC60502-1 cu/pvc insulated/pvc sheathed 1kv 4x6sqmm aluminum cable Application: IEC60502-1 cu/pvc ...