MV monoconductor cable xlpe insulated copper wire screened cable 18/30kv 1Cx150sqmm IEC60502-2

 

MV monoconductor cable xlpe insulated copper wire screened cable 18/30kv 1Cx150sqmm IEC60502-2 ​APPLICATIONS:

Single core MV Power Cables 12kv CU/XLPE/PVC 1Cx150sqmm cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 12/20(24)KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

 

STANDARD:

IEC 60502 Part 2(3.6/6KV to 18/30KV)

 

Cable Construction

We adopt highly specialized plant, state-of-the-art research facilities and meticulous quality control procedures that are required for the manufacturing of xlpe insulated cables for use up to 6KV and XLPE insulated cables for use at voltages up to 35 KV. 

 

Conductors

Either aluminium or copper conductors are used. Conductors will be circular, compacted & stranded and shall comply with IEC 60228 class 2. 

 

Conductor Screen

This will be an extruded layer of semi-conducting crosslinkable compound applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen. The triple extrusion is a single high precision operation that eliminates the possibility of any contamination between the layers which could create irregularities in the electrical field. By careful material selection and special attention to process parameters, we produce the insulation screen layers with the required degree of stripping force as stipulated by the applicable national or international standard.

Insulation

This will be an extruded layer of XLPE applied over conductor screen under triple extrusion process along with conductor screen and insulation screen.

Insulation Screen

This will be a layer of semi-conducting crosslinkable compound which will be applied by triple extrusion process over the insulation.

Metallic Screen

It will consist of a layer of copper tape applied helically with overlap over insulation screen. Other combinations of metallic screens as per customer ’s requirement can also be provided on request.

Laying-Up

In case of three core cables, the three cores are laid up with non-hygroscopic fillers like polypropylene(PP) fillers at interstices and a binder tape is applied with an overlap. These binder tapes can be of PVC or foamed Polyethylene.

Over Sheath

An extruded layer is applied over the armour in case of armoured cables and over laid up cores in case of unarmoured cables. Outer sheath material can be either PVC, PE, HDPE or MDPE. our

medium voltage cables are normally supplied with red PVC over sheaths complying with BS 6622 or IEC 60502. Other colors may be provided to suit a range of installation considerations such as the effect of UV radiations and differing soil compositions. Anti-termite formulations can also be supplied in addition to graphite-coated over sheaths where on-site testing of the sheath is required.

 

Fire Performance on Cable Sheaths

Cables can also be supplied with special flame retardant PVC over sheaths to comply with the IEC 60332 standard. We can also supply cables with Low Smoke Halogen Free (LSZH) sheaths according to BS 7211 and BS 6724 standards or other equivalent international standards.

 

 

MV monoconductor cable xlpe insulated copper wire screened cable 18/30kv 1Cx150sqmm IEC60502-2 ​ ​reference technical parameters

Nom.

Cross-

Section

Area

 Unarmoured CablesAluminium Wire Armoured Cables

Nom.

Insulation

Thickness

Copper

Tape

Thickness

Copper

Wire

Screen

Area*

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

Weight

Nom.

Bedding

Thickness

Armour

Wire

Size

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

Weight
CuALCUAL
mm²mmmmmm²mmmmkg/kmmmmmmmmmkg/km
163.40.1161.8184503501.21.61.824770670
253.40.1161.8205604001.21.61.825910750
353.40.1161.8216804601.21.61.8261040820
503.40.1161.8228105201.21.61.8281190900
703.40.1161.82410506201.21.61.92914701040
953.40.1161.82513207301.21.62.03117801190
1203.40.1161.82715808401.22.02.03421501410
1503.40.1251.92818809601.22.02.13524801560
1853.40.1251.930225011001.22.02.13728901730
2403.40.1252.033287013501.22.02.24035702050
3003.40.1252.135349015801.22.02.34242302330
4003.40.1352.239435019201.32.52.44753202890
5003.40.1352.239.9523522401.42.52.55165103530
6303.40.1352.343.7667527651.52.52.65679604050

 

Single Core 18/30KV Dimensional Data

Nom.

Cross-

Section

Area

 Unarmoured CablesAluminium Wire Armoured Cables
 

Nom.

Insulation

Thickness

Copper

Tape

Thickness

Copper

Wire

Screen

Area*

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

Weight

Nom.

Bedding

Thickness

Armour

Wire

Size

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

Weight
      CUAL    CuAL
mm²mmmmmm²mmmmkg/kmmmmmmmmmkg/km
508.00.1162.03112509601.22.02.23819101640
708.00.1162.034151010901.22.02.34122401820
958.00.1162.135183012401.22.02.34225701980
1208.00.1162.137211013601.32.52.44530602310
1508.00.1252.238242015101.32.52.54734302510
1858.00.1252.240283016801.32.52.55038902720
2408.00.1252.343350019801.42.52.65246303120
3008.00.1252.445415022501.42.52.75453303430
4008.00.1352.549507026401.52.52.85863603930
5008.00.1352.652594529651.62.52.96176704490
6308.00.1352.756744535551.72.53.06588705020

 

MV monoconductor cable xlpe insulated copper wire screened cable 18/30kv 1Cx150sqmm IEC60502-2  images

single core MV cable 1x150

 

 

MV monoconductor cable xlpe insulated copper wire screened cable 18/30kv 1Cx150sqmm IEC60502-2 ​​​ Package

 

Cable testing 


 


About Zhenglan Cable Technology Co., Ltd

Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.

 

 

Why Choose Zhenglan Cable:

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.

FAQ
1. Is your company a factory or a trade company?
Factory, more than 20 years in China

2. How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.

 

3. What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.

4. What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.

 

5. What is your MOQ?
Generally for medinum voltage poer cable MOQ is 1000m.

 

Hot Products

1kv PVC insulated copper cable 4x50mm2 low voltage power cable Application: 1kv PVC insulated copper ...
1kv XLPE insulated power cable N2XY 4x16mm2 Cu/XLPE/PVC IEC60502-1 Application: 1kv XLPE insulated ...
1kv Cu/xlpe/lszh N2XH 4x35+1x16mm2 power cable LV power cable Application: 1kv Cu/xlpe/lszh N2XH ...
12/20(24)kV 12.7/22(24)kV Three Cores Al/Cu conductor XLPE/PVC insulated LZSH jacket Armoured Power ...
3x150mm2 aluminium/copper conductor STA armored PVC sheath cable MV Underground Cable BS 6622/BS ...
8.7/15kV Medium Voltage 3X185mm2 Copper Or Aluminum Conductor XLPE insulated PVC jacekt Power Cables ...