Overhead Alloy Bare Aluminum Conductor Wire AAAC 120mm2 2.8mm DIN48201

Country/Region china
City & Province zhengzhou henan
Categories Electrical Wires
InquireNow

Product Details

Overhead Bare Conductor Wire AAAC 120mm2 19/2.8mm All Aluminum Alloy Conductor DIN48201/IEC61089

 

APPLICATION: AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.

 

STANDARD

Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201 -6 standards.

 

CONSTRUCTION of Overhead Alloy Bare Aluminum Conductor Wire AAAC 120mm2 2.8mm DIN48201

AAAC cable bvconsists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.

This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant standard. Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher strength but lower conductivity than pure aluminium. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR; Having lower breaking loads than the later, their use becomes particularly favourable when ice and wind loadings are low.

 

(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

 

ELECTRICAL PROPERTIES

density@20ºC2.70 kg/dm
Temperature Coefficient@20°C0.00360 (°C)
resistivity@20°C0.0326 Ohms mm2/m
linear Expansivity

23 x10-6 (°C)

 

SERVICE CONDITIONS

Ambient Temperature-5°C - 50°C
Wind Pressure80 – 130kg/m
Seismic Acceleration0.12 - 0.05g
Isokeraunic level10 – 18
relative Humidity5 – 100%

 

Overhead Bare Conductor Wire(Nominal Area:18.4~1439mm2), AAAC Conductor according to IEC 61089 CONSTRUCTION PARAMETERS

 

• IEC 60189

Code NumberNo. of WiresA2 ConductorsMax. DC Resistance of Conductor at 20°C
Calculated AreaDiameter of WiresDiameter of ConductorApprox. WeightRated Strength
mm²-mm²mmmmkg/kmdaNΩ/km
16718.41.835.4950.45.431.7896
25728.82.296.8778.78.491.1453
407462.898.67125.913.580.7158
63772.53.6310.8198.321.390.4545
100191152.7813.9316.333.950.2877
125191443.115.5395.442.440.2302
160191843.5117.55506.154.320.1798
200192303.9319.65623.767.910.1439
250192884.3921.95790.884.680.1151
315373633.5324.71998.9106.950.0916
400374603.9827.861268.4135.810.0721
450375184.2229.541426.9152.790.0641
500375754.4531.151585.5169.760.0577
560616453.6733.031778.4190.140.0516
630617253.8935.012000.7213.90.0458
710618174.1337.172254.8241.070.0407
800619214.3839.422540.6271.620.0361
9009110363.8141.912861.1305.580.0321
10009111514.0144.113179339.530.0289
11209112894.2546.753560.5380.270 0258

   

AAAC conductor-DIN 48201 Part 6
Nominal AreaStrandingOverall DiameterWeightRated StrengthElectrical ResistanceCurrent Rating*
NominalTeorical
mm^2mm^2No.xmmmmkg/kmKNΩ/KmA
1615.897/1.705.1434.442.074278
2524.257/2.106.3666.771.3593102
3534.367/2.507.5949.60.9591126
5049.487/3.00913513.820.666158
5048.3519/1.80913313.50.6849156
7065.8119/2.1010.518118.380.5032189
9593.2719/2.5012.525626.050.3551234
120116.9919/2.801432232.680.2831269
150147.1137/2.2515.840641.090.2256309
185181.6237/2.5017.550050.730.1828352
240242.5461/2.2520.367067.740.1371420
300299.4361/2.5022.582783.630.111477
400400.1461/2.89261104111.760.0831568
500499.8361/3.2329.11379139.60.0665649
625*626.291/2.9632.61732174.90.0531742
800*802.0991/3.3536.92218224.020.0415857
1000*999.7191/3.7441.12767279.220.0333971

 

Overhead Alloy Bare Aluminum Conductor Wire AAAC 120mm2 2.8mm DIN48201 images

Why you choose us?

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.

 

Hot Products

1kv PVC insulated copper cable 4x50mm2 low voltage power cable Application: 1kv PVC insulated copper ...
1kv XLPE insulated power cable N2XY 4x16mm2 Cu/XLPE/PVC IEC60502-1 Application: 1kv XLPE insulated ...
1kv Cu/xlpe/lszh N2XH 4x35+1x16mm2 power cable LV power cable Application: 1kv Cu/xlpe/lszh N2XH ...
Product Description: The SWA/STA Armoured character of these cables is designed to provide ...
Product Description: Made to a range of international standards including IEC 60502, BS 6622, ASTM B...
Product Description: The installation method for Medium Voltage Power Cables is versatile, as they ...