ACSR 185/30mm2 overhead bare conductor aluminum conductor steel reinforced IEC61089

 

Application 

ACSR are usually used as bare overhead transmission cable and as primary and secondary distribution cable. They have a long service record because of its economy, dependability, and strength to weight ratio.

 

Bare Conductor Electrical Cable STANDARD

Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.

 

Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

 

Bare Conductor Electrical Cable CONSTRUCTION

ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.

By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.

 

ELECTRICAL PROPERTIES

density@20ºCAluminium: 2.703 kg/dm
Galvanised Steel: 7.80 kg/dm
Temperature Coefficient@20°CAluminium: 0.00403 (°C)
resistivity@20°CAluminium: Should not exceed 0.028264

linear Expansivity

 

Aluminium: 23 x10 (°C)
Galvanised Steel: 11.5 x10 (1/°C)

 

SERVICE CONDITIONS

Ambient Temperature-5°C - 50°C
Wind Pressure80 – 130kg/m
Seismic Acceleration0.12 - 0.05g
Isokeraunic level10 – 18
relative Humidity5 – 100%

 

TECHNICAL DATA

Numbers of WiresModules of ElasticityCoeficient of linear Expansion
ALSTEELKg/mm2Lb/in21/Cº1/Fº
618111.5 x10619.1 x10-610.6 x10-6
677711.0 x10619.8 x10-611.0 x10-6
12710715.2 x10615.3 x10-68.5 x10-6
181679.5 x10621.2 x10-611.8 x10-6
2477410.5 x10619.6 x10-610.9 x10-6
2677710.9 x10618.9 x10-610.5 x10-6
2877911.2 x10618.4 x10-610.2 x10-6
3078211.6 x10617.8 x10-69.9 x10-6
30198011.4 x10618.0 x10-610.0 x10-6
32198211.7 x10617.5 x10-69.7 x10-6
547709.9 x10619.3 x10-610.7 x10-6
5419689.7 x10619.4 x10-610.8 x10-6

 

Parameters

 

CodeNominal AreaStrandingOverall DiameterWeightBreaking Load

Electrical

Resistance @20°

 ALSTEELTOTALALSTEEL    
 mm2mm2mm2No.xmmNo.xmmmmKg/KmKNΩ/Km
16162.5618.76/1.841/1.845.5364.66.081.7934
25254.1729.26/2.301/2.306.9100.99.131.1478
40406.6746.76/2.911/2.918.73161.514.40.7174
636310.573.56/3.661/3.6610.98254.421.630.4555
10010016.71176/4.611/4.6113.83403.834.330.2869
1251256.9413218/2.971/2.9714.85397.929.170.2304
12512520.414526/2.477/1.9215.64503.945.690.231
1601608.8916918/3.361/3.3616.8509.336.180.18
16016026.118626/2.807/2.1817.74644.957.690.1805
20020011.121118/3.761/3.7618.8636.744.220.144
20020032.623326/3.137/2.4319.81806.270.130.1444
25025024.627522/3.807/2.1121.53880.668.720.1154
25025040.729126/3.507/2.7222.161007.787.670.1155
31531521.833745/2.997/1.9923.911039.679.030.0917
31531551.336626/3.937/3.0524.871269.7106.830.0917
40040027.742845/3.367/2.2426.881320.198.360.0722
40040051.945254/3.077/3.0727.631510.3123.040.0723
45045031.148145/3.577/2.3828.561485.2107.470.0642
45045058.350854/3.267/3.2629.341699.1138.420.0643
50050034.653545/3.767/2.5130.091650.2119.410.0578
50050064.856554/3.437/3.4330.871887.9153.80.0578
56056038.759945/3.987/2.6531.831848.2133.740.0516
560*56070.963154/3.6319/2.1832.682103.4172.590.0516
63063043.667445/4.227/2.8133.752079.2150.450.0459
630*63079.871054/3.8519/2.3134.652366.3191.770.0459
71071049.175945/4.487/2.9935.852343.2169.560.0407
710*71089.980054/4.0919/2.4536.792666.8216.120.0407
800*80034.683572/3.767/2.5137.612480.2167.410.0361
800*80066.786784/3.487/3.4838.282732.7205.330.0362
800*80010190154/4.3419/2.6139.093004.9243.520.0362
900*90038.993972/3.997/2.6639.92790.2188.330.0321
900*9007597584/3.697/3.6940.593074.2226.50.0322
1000*100043.2104372/4.217/2.8042.083100.3209.260.0289

 

 

 
 
About Us
We, Zhenglan Cable Technology Co., Ltd, are manufacturer of cable and wire with over 20years' experience.
Our factory workshop taking up about 60000SQM is located in Wuzhi County, Jiaozuo city, Henan province, in the middle of China.
Oversea sales center locates in Zhengzhou city, Henan, about 10minutes walk to Zhengdong Railway station, 45minutes' drive to Xinzheng International Airport.
Our main products are
  • overhead transmission line use bare conductor(ACSR, AAC, AAAC etc)
  • 1-35kv overhead transmission line use insulated conductor
  • power distribution use 0.6/1kv, 1.8/3kv PVC/XLPE/PE insulated LV(low voltage) power cable armored or unarmored
  • power distribution use 3.6/6kv, 6/10kv,8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv XLPE insulated MV(medium voltage) power cable armored or unarmored;
  • 300/300V, 300/500V, 450/750V cotrol cable, house wire

 

Hot Products

1kv PVC insulated copper cable 4x50mm2 low voltage power cable Application: 1kv PVC insulated copper ...
1kv XLPE insulated power cable N2XY 4x16mm2 Cu/XLPE/PVC IEC60502-1 Application: 1kv XLPE insulated ...
1kv Cu/xlpe/lszh N2XH 4x35+1x16mm2 power cable LV power cable Application: 1kv Cu/xlpe/lszh N2XH ...
Product Description: The SWA/STA Armoured character of these cables is designed to provide ...
Product Description: Made to a range of international standards including IEC 60502, BS 6622, ASTM B...
Product Description: The installation method for Medium Voltage Power Cables is versatile, as they ...