Product Details

Performance Parameters

 

Model

Adjustment Range

PSI Bar

Avg. Differential

 

Model

Adjustment Range

PSI Bar

Avg. Differential
 

 

1 1.5-30 0.10-2.0

1A 14.5-200 1.0-14

Less than 10% of Actuation Point

3 300-2500 20-170

4 3000-6000 207-414

Less than 10% of Actuation Point

 

2 125-600 8-40 5 500-3500 35-240

 

ELECTRICAL:

100VA/42VDC

Gold contacts may be required for less than 12 VDC and 20 milliamp WETTED MATERIAL:

Diaphragm: Buna-N (standard) (optional EPDM, KAPTON®, VITON® Low Temperature Nitrile)

Housing: Zinc-Nickel Plated Steel (optional Steel - Electroless Nickel Plated, 316 Stainless Steel)

PROTECTION:

Exposed Terminals - IP00

Flying Leads & Deutsch Integral - IP69

REPEATABILITY:

± 3% of full set point range at 21°C Ambient Temperature

SWITCH TYPE:

Creep Action

MECHANICAL LIFE:

1,000,000 cycles

TEMPERATURE RANGE:

BUNA-N: -26℃~110℃ EPDM: -23℃~121℃ KAPTON®: -40℃~110℃ VITON®: -18℃~150℃

(® Registered Trademark of DuPont)

Low Temp Nitrile: -40℃~110℃ MAXIMUM OVERPRESSURE: 9000 PSI (620 Bar)

WEIGHT:

0.07 kg

 

 

WEP1-*2-*R-4M-A-FL-*1
ModelSet PointDirectionPort SizeCircuitTerminalOptions

WEP1-

Field Adjustable

 

WEP6-

Factory Set

See Above Adjustment Ranges

 

*Model WEP6 Specify Set Point Required

R-PSI

Rising F-PSI

Falling BR-Bar Rising BF-Bar Falling

 

*Omit for Model WEP1

2M-1/8 NPT

4M-1/4 NPT

2G-1/8 BSPP

4G-1/4 BSPP

(undercut for an o-ring seal)

4GS-1/4 BSPP (no

undercut)

4S-7/16×20 SAE MALE

6S-9/16×18 SAE MALE

M10-M10×1* M12-M12×1.5*

A-SPST/NO B-SPST/NC

SP-1/4"x1/32" Spade

TS-6-32 Terminal Screws FL-18" Flying Leads

FLL-Advise additional length of leads if required

FLWTF-Weatherpack Tower Female

FLWTM-Weatherpack Tower Male FLWSF-Weatherpack Shroud Female

FLWSM-Weatherpack Shroud Male

DI-Deutsch Integral

*-Omit If Standard 1-VITON®

Diaphragm

2-EPDM Diaphragm 3-KAPTON®

Diaphragm *

* Ranges 1A & 2 Only 15 - Low Temp Nitrile Dia

4-316 SS Housing 4A-Steel-Electroless Nickel Plated

5- Spiral Restrictor

6- Oxygen Cleaned 7-Gold Contacts

   

*Consult Factory for

Specials

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix 1: Definitions and Terms
DEFINITIONS AND TERMINOLOGYStandard Electrical Circuit

 

ACCURACY, (REPEATABILITY) - Accuracy is the maximum allowable set point deviation of a single pressure or temperature

Wire Color

DIN 43650

Number

C

Circuit

 

switch under one given set of environmental and operational conditions.

ACTUATION AND DEACTUATION POINT - The actuation point (sometimes called set point) is the exact point at which the electrical circuit controlled by the switching element is opened (or closed) on increasing pressure or temperature. The deactuation point is the opposite at which the electrical circuit is closed (or opened) on decreasing pressure or temperature.

DEAD BAND - The dead band sometimes referred to as “differential” or “hysteresis” is the change in pressure between actuation and deactuation set points.

PRESSURE SWITCH - An instrument that upon the increase or decrease of a pressure or vacuum, opens or closes one or more electrical switching elements at a predetermined actuation point (setting).

PRESSURE SENSING ELEMENT - That portion of pressure switch that is in contact with and moves as a result of a change in pressure of the medium. The most common type of pressure sensing elements are diaphragms, accordion bellows, bourdon tubes, and pistons.

SINGLE POLE DOUBLE THROW (SPDT) SWITCHING ELEMENT -

A SPDT switching element has one normally open, one normally closed and one common terminal. Three terminals mean that the switch can be wired with the circuit either normally open (N/O) or normally closed (N/C).

NORMALLY CLOSED SWITCHING ELEMENT (NC) - Is one in which

the terminals are wired so that current can flow through the switching element until pressure is applied to open the electrical circuit.

NORMALLY OPEN SWITCHING ELEMENT (NO) - Is one in which

the terminals are wired so that no current can flow through the switching element until the pressure is applied to close the electrical circuit.

PRESSURE, PROOF - Proof Pressure is the maximum pressure which can be applied to any switch without causing permanent degradation.

Circuit Definitions

Form A - SPST - NO

Single Pole - Single Throw Normally Open

Form B - SPST - NC

Single Pole - Single Throw Normally Closed

Form C – SPDT

Single Pole - Double Throw

Black 1 Common

Green 2 N. Closed

Red 3 N. Open

Wotian Pressure Switches are sealed, vibration resistant and ruggedly built to provide a reliable protection for automatic control of equipment and processes. They are designed for direct or remote mounting and offer a quality product at a competitive price.

Setting - The set point of each switch is preset at the factory as follows:

  • Field adjustable series - bottom of range
  • Factory set series - at the desired set point

The switches can be ordered for operation with either rising or falling temperature, vacuum or pressure. Reset of the microswitch is automatic and depends upon the dead band or differential of the particular model.

Switch Protection - Standard switches offer excellent protection and long life in most applications. They are also sealed for weatherproof protection. The corrosion-resistant materials in the wetted areas and the standard nitrile diaphragm are suitable for most media. Where required the switches are available with VITON®, KAPTON®, EPDM or Low Temperature Nitrile diaphragms and, in some cases, optional steel, brass or stainless steel housings and wetted areas.

Mechanism - Where the pressure switch is subject to higher pressure, either dynamic or static, of over 700 psi, the diaphragm operating mechanism includes an O-ring cushion which absorbs the slight operation motion required while preventing extrusion of the diaphragm material into the piston-to-cylinder clearance.

Gold Contacts - May be required for applications where less than 12VDC and 20 Milliamps

Hot Products

Product overview WS10 piezoresistive silicon pressure sensor is the core component for the ...
Product overview WS15 industrial pressure sensor is a standard and most popular sensor applied in ...
Model Adjustment Range PSI Bar Avg. Differential PSI Bar Model Adjustment Range PSI Bar Avg. ...
Performance Parameters Model Adjustment Range PSI Bar Avg. Differential PSI Bar Model Adjustment ...
Performance Parameters Model Adjustment Range PSI Bar Avg. Differential Model Adjustment Range PSI ...
Product overview WPM-63 Differential Pressure Transmitter is based on 2 absolute pressure sensors, ...