Wireless ON OFF Control Module 915MHz Lora Wireless I O Module 4DI 4DO Wireless PLC

 

 

1. LS-RDIO series module general introduction

LS-RDIO Modbus RTU is an industrial controller designed by Lensen Technology. It supports point to point, point to multi-points wireless DI, DO, AI, AO collection and control. This transceiver has the advantage of easy installation, no program required, no communication fee. It is reliable and cost-effective substitution for rail signal cable, slip ring signal wire.

 

LS-RDIO0404 has 4 inputs 4 relay outputs and 1 RS485(wireless RS485 customized). Power output we have 2 versions, one is 100mW for 1km LOS control distance, and another one is 1W for 3km LOS control distance.

 

 

2. Application Field

LS-RDIO series I/O module is widely used in industry automation like factory central data process, pump control, tank level monitoring, Conveyor Control,oil monitoring, mining machinery, environment monitoring equipment, lifting devices, robots control, filling machine, mixing equipment, logistic line, AGV etc.

 

 

3. Parameter of RDIO0404

Parameter
Power output:1W or 100mW version
Power supply:9V-30V (usually choose 24V DC or 12V DC)
Control distance:3km or (1km version)
Baud rate:2400bps default
Receiving sensibility:-123dBm@1200bps, -118dbm(9600bps)
Networking
Networking:Point to point and point to multipoints
Port Description
Input:4 digital active inputs(passive customize)
Output:

4 relay outputs,

contact max load AC250V/5A,DC30V/5A

(active outputs 0-5V customize)

Communication portRS485 (wireless RS485 customize)
Current
Transmit current:<600mA (or 100mA version)
Receiving current:<50mA (or 20mA version)
General
Frequency:433MHz, 450, 470 or other band
Channel No:16 channels,can change via DIP switch
Physical Properties
Dimension:115×90×40(mm)
Antenna Connector:SMA,vehicle antenna with 1.5m cable
Temperature:35℃~+75℃( industrial)
Mounting method:Standard 3.5 inch industrial guild rail
 

4. Modbus RTU communication and value calculation

A. Register types:

Register typesRead command

Write command

(Control command)

Power offFunction
coil register0x01

Input --not support

Output-support

Not keepCan read input value
Hold register0x03

1) Coil register:

Input: it is not convenient to read 8 I/O at one time. In order to control each I/O correspondingly, we defined coil register. The register address is 0x0000-0x0007.

Output: it is not convenient to control 8 I/O at one time. In order to control each I/O correspondingly, we defined coil register whose address is 0x0020-0x0028.

Note: The coil is not extra resource, just a method for register addressing---addressing by bit.

2) Holding register:

a. value of input channels: 0x0000

Note: addressing by bit means we only use the first 8 bits; bit0 to bit7 corresponds with I / O1 to I / O8;

b: feedback and value of output channels: 0x0040

Note: addressing by bit means bit 0 corresponds with 1/O1, bit 7 corresponds with 1/O8, bit 8-bit 15 corresponding value we write 0.

3) Reading method:

Coil register: Directly read the responding register. 1 means OFF, 0 means ON.

Holding register: Can read all 8 inputs state one time. We only use bit0-bit7 of this 16-bit register; each bit represents the state of an input.

4) Control methods:

a. Use the coil--- directly writes the corresponding coil register you can control corresponding output.

b. Use the holding register--- eight outputs share 1 holding register, so you can manage each bit separately to control the responding output.

B. About register control

 IC

Read/

write

Function codeProducts apply
ChannelIC typePLC IDModbus ID
DI1Coil reg.10read01

RDIO0202

RDIO0404

RDIO0808

Holding reg.40001.00.0read03
DI2Coil reg.21read01
Holding reg.40001.10.1read03
DI3Coil reg.32read01

RDIO0404

RDIO0808

Holding reg.40001.20.2read03
DI4Coil reg.43read01
Holding reg.40001.30.3read03
DI5Coil reg.54read01RDIO0808
Holding reg.40001.40.4read03
DI6Coil reg.65read01
Holding reg.40001.50.5read03
DI7Coil reg.76read01
Holding reg.40001.60.6read03
DI8Coil reg.87read01
Holding reg.40001.70.7read03
DO1Coil reg.3332

Read/

write

01/05

RDIO0202

RDIO0404

RDIO0808

Holding reg.40065.064.0

Read/

write

03/06
DO2Coil reg.3433

Read/

write

01/05
Holding reg.40065.164.1

Read/

write

03/06
DO3Coil reg.3534

Read/

write

01/05

RDIO0404

RDIO0808

Holding reg.40065.264.2

Read/

write

03/06
DO4Coil reg.3635

Read/

write

01/05
Holding reg.40065.364.3

Read/

write

03/06
DO5Coil reg.3736

Read/

write

01/05RDIO0808
Holding reg.40065.464.4

Read/

write

03/06
DO6Coil reg.3837

Read/

write

01/05
Holding reg.40065.564.5

Read/

write

03/06
DO7Coil reg.3938

Read/

write

01/05
Holding reg.40065.664.6

Read/

write

03/06
DO8Coil reg.4039

Read/

write

01/05
Holding reg.40065.764.7

Read/

write

03/06
 

 

 

Hot Products

433MHz Wireless Modbus RTU , Wireless Tank Level Monitor System 2km Remote Control Pump 2DO This is ...
16DI 16DO Wireless I O Module PLC Wireless Controller 2km Wireless ON OFF Control Introduction 16DI ...
2km Wireless Modbus RTU I O Module Wireless ON OFF Control One Master To 8 Slaves 1. LS-R324 General ...
Digital Input Wireless Modbus RTU 2km Wireless Pump Control 868MHz Wireless Lora Module 1. LS-RDIO ...
Wireless ON OFF Control Module 915MHz Lora Wireless I O Module 4DI 4DO Wireless PLC 1. LS-RDIO ...
8DI8DO Wireless Modbus RTU Wireless Pump Control 8 Inputs / Outputs White Plastic Enclosure 1. LS...