433MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog Signal 2DO

Country/Region china
City & Province shenzhen guangdong
Categories Solar Chargers
InquireNow

Product Details

33MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog Signal 2DO

 

 

Advantage of wireless solution

No wires to bury or maintain, no need to drill holes on wall

Reliable communication in all direction,any terrain, regardless of hills, walls, trees

Cost saving in installation and maintenance

Radio based, no need internet and monthly fee, full ownership of the system

 

 

Wireless RTU features

- Portable device, DIN-rail mounting for easy installation

- Isolated inputs

- LEDs for power supply, communication, input, output status

- Flexible networking, point to point or point to multipoints

- DIP to change different modes

- Different types of I/O, DI, DO, AI, AO are available

- I/O expandable

- Short delay time

- Support I/O reduction, field input, remote output

- Easy handing on RS485 network, support Modbus RTU protocol

- Support on-line upgrade. Can configure by customer in setting mode

 

 

Projects Description:
1. Customer needs to minitor 10 tanks.
2. Intake or glow-off water by start/off the pumps or the valves.
3. Distance is within 1km.
4. Need wireless solution
 
 
LS-RAI02
Frequency433MHz or 450MHz or 470MHz
Power output100mW(600m),1000mW(3000m)
Products2AI,4AI,2AO,4AO
Input type4-20mA or 0-5V or 0-10V
Output type4-20mA or 0-5V or 0-10V
Resolution ratio24 bit
Accuracy±0.02%
Power supply9-36V DC usually use 24V DC
InterfaceRS-485
Channel No.16ch default, can program via DIP switch
AntennaSucker antenna with 1.5m cable
Working temperature-35℃~+75℃ industrial
Working humidity10%~90% relative humidity, no condensation
Dimension2AI,4AI115×90×40(mm)
2AO,4AO
Fix wayStandard 3.5 inch industrial DIN guild rail
 
LS-RDIO0202
Parameter
Power output:1W (or 100mW version)
Power supply:9V-30V (usually choose 24V DC or 12V DC)
Control distance:3km (or 1km version)
Baud rate:1200bps
Receiving sensibility:-123dBm@1200bps, -118dbm(9600bps)
Networking
Networking:Point to point and point to multipoint
Protocol:Modbus RTU protocol
Port Description
Input:2 active inputs (passive customize), isolated
Output:

2 passive relay outputs, isolated

contact max load AC250V/5A,DC30V/5A

(active outputs 0-5V customize)

Communication portRS485 (wireless RS485 customize)
Current
Transmit current:<600mA (or 100mA version)
Receiving current:<50mA (or 20mA version)
General
Frequency:433MHz, 400, 450, 470 or other band
Channel No:16 channels, can change via DIP switch
Physical Properties
Dimension:115×90×40(mm)
Antenna Connector:SMA,vehicle antenna with 1.5m cable
Temperature:-35℃~+75℃( industrial)
Mounting method:Standard 3.5 inch industrial guild rail
 
It is 1 master to many slaves application. Support Modbus RTU protocol.
 
Master is the PLC at RO plant. This side we recommend a LS-R324 to connect with PLC and RO Plant. LS-R324 is to collect all slave's data, forward to PLC for analysis. PLC process data, give command to RO Plant.
 
Slaves are the sensors on tank, the valves and the pumps.
 
a. About level sensors, there are 2 types, because there is salt water, to avoid Corrosion, we don't suggest thrown-in type sensor. Ultrasonic level sensor is more recommended.
Each sensor, you need an analog I/O module to collect and transmit the level sensor's 4-20mA signal to PLC. Use our LS-RAI02 module, it has 2 analog inputs.
 
b. About the pump, each one, you need a digital I/O module to start or close the pump. It is to control when we should intake water according tank level. Here we recommend LS-RDIO0202, it has 2 digital inputs and 2 relay outputs.
 
c. About the valves, each one, you need a digital I/O to start or close the valve. It is to control when we should blow off water according the tank level. Here we recommend LS-RDIO0202, it has 2 digital inputs and 2 relay outputs.
 

Hot Products

4-20mA Wireless Control System 2 Analog Inputs 2 Analog Outputs 2km Wireless Analog System ...
2-3km Wireless I O Module 4-20mA Wireless Signal Transmission 2 Channels AI 0-5v Introduction LS...
33MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog Signal 2DO Advantage ...
4-20mA Wireless I O Module Analog Input / Output Module Wireless Sensor Transmitter Advantage of ...
868MHz Wireless Analog I O Module 1W Modbus RTU 2 Channels 4-20mA / 2 Channels 0-5V Sensor ...
Industry Wireless I O Module Ethernet DI DO Wireless AI AO Controller 1W Power Output 1. General ...