1000W 48V Yellow Color Wind Solar Hybrid Controller Inverter For Famaily
Problem | Possible Cause | Solution |
LCD has no display | Battery wire connection loose | Check connection, reconnect battery cables firmly. |
Battery voltage is lower than apparatus working voltage | 1. Check battery voltage until battery voltage reaches to device working voltage. | |
2. Check battery connection, please reconnect correctly or increase battery banks. | ||
Fuse is burnt | Open box, then change fuse. | |
LCD wiring connection loose | Open device box, reconnect LCD wiring. | |
Input over voltage protection | Battery is over-voltage | LCD display” HIGH BATTERY”, please disconnect all the wirings first and then re-connect them. |
Battery over discharge protection | Battery is under-voltage | LCD displays “LOW BATTERY”. After battery voltage rises up to the ‘over discharge recovery voltage’, the inverter will recover automatically. |
Overload protection | Load power exceeds device rated output capacity | LCD displays “OVER LOAD” constantly. Turn off the inverter and check the load, deduce some loads, then restart the inverter again. |
Load Short-circuit | Short-circuit on the AC LOAD | LCD displays “OVER LOAD” flashing. Turn off the inverter, check load and wiring, remove the short-circuit hazard or damaged load, then turn on the inverter again |
Over temperature protection | Improper installation | Installation should be in well-ventilated areas |
The vents are blocked | Make the area around fan-cover clean. | |
Something wrong with the fan. | Contact manufacturer. | |
No AC output | Inverter switch is in “OFF” position. | Turn on the inverter |
LCD displays HIGH BATTERY, LOWBATTERY,OVER LOAD,HIGH TEMPERATURE | Please refer to the above corresponding solution. | |
No charging | Wind turbine, solar panel connections is loose | Re-connect and make sure wiring tight. |
wind turbine voltage and PV voltage are not reaching charging condition | Check the real output voltage and check whether is system configuration is correct. | |
BRAKE | Switch the brake to “RUN” position. | |
Battery full-charged | Check whether battery voltage reaches floating charge voltage or charge current reaches to unload current. |
Technical Data
Product Model | HY-CI10-48AWMMT |
Rated Wind Power | 1kW |
Rated Solar Power | 1kW |
Floating Charge Voltage | 58V |
Dump load Current | 21A |
Rated Output Power | 1kW |
Rated Battery Voltage | 48VDC |
Over Voltage Shutoff | 68VDC |
Over Voltage Recovery | 66VDC |
Under Voltage Shutoff | 43.2VDC |
Under Voltage Recovery | 48VDC |
No-load Loss Current | ≤0.5A |
Output Wave | Pure Sine Wave |
Display Mode | LCD |
Cooling | Fan |
Rated Output Voltage | 220 VAC |
Wave Distortion | ≤4% |
Output Frequency | 50±0.5Hz |
Dynamic Response | 5% |
Power Factor | ≥0.8 |
Over-load Capacity | 120% 1 min; 150% 10s |
Inverter Efficiency | Maximum 90% |
Isolating Mode | Frequency Toroidal transformer |
Noise (1 m) | ≤40dB |
Insulating Strength | 1500VAC,1 min |
Protection Function | Solar reverse charge protection , Solar reverse connection
protection, |
Ambient Temperature | -20~+55℃ |
Working Altitude | ≤4000m |
Ambient Humidity | 0~90%, without condensing |
Company Picture:
FAQ
1. Which payment terms are available?
A: Our company accept Telegraphic Transfer (T/T) payment for sample
and bulk order.
2. How long will my order ready?
A: The delivery time is within 5 working days upon the payment
receipt for the sample order.
3. I need the other accessories besides the wind turbine, do you
also provide them?
A: Yes, we can supply not only the wind turbine but also the other
parts of the system. E.g: controller, inverter.
Can you help me to design the system for my home and provide all
accessories?
A: No problem. We can give you professorial technical advice and
design the power system according to your request.