WUHAN XIEYUAN AUTOMATION EQUIPMENT CO.,LTD |
|
Descriptions
Specifications
EJX930A Multivariable Transmitter | |||||
M Capsule | H Capsule | ||||
Range | Differential pressure | -100 to 100 kPa (-400 to 400 inH2O) | -500 to 500 kPa (-2000 to 2000 inH2O) | ||
Static pressure | Absolute | 0 to 32 MPa abs (0 to 4500 psia) | |||
Gauge | -0.1 to 32 MPa (-14.5 to 4500 psig) | ||||
External temperature | -200 to 800 deg C (-328 to 1472 deg F) | ||||
Span | Differential pressure | 1 to 100 kPa (4 to 400 inH2O) | 5 to 500 kPa (20 to 2000 inH2O) | ||
Static pressure | Absolute/ Gauge | 1 to 32 MPa (145 to 4500 psi) | |||
External temperature | 10 to 1050 deg C (18 to 1890 deg F) | ||||
Accuracy | Mass flow | ±1.0% | |||
Differential pressure | ±0.04% | ||||
Static pressure | ±0.1% | ||||
External temperature | ±0.5 deg C (±0.9 deg F) | ||||
Flow calculation reference | Primary device | Orifice | Orifice Corner Taps [ISO5167-1 1991] | ||
Orifice Corner Taps [ISO5167-2 2003] | |||||
Orifice Corner Taps [ASME MFC-3M 1989] | |||||
Orifice Frange Taps [ISO5167-1 1991] | |||||
Orifice Frange Taps [ISO5167-2 2003] | |||||
Orifice Frange Taps [ASME MFC-3M 1989] | |||||
Orifice Frange Taps [AGA No.3 1992] | |||||
Orifice D and D/2 Taps [ISO5167-1 1991] | |||||
Orifice D and D/2 Taps [ISO5167-2 2003] | |||||
Orifice D and D/2 Taps [ASME MFC-3M 1989] | |||||
Nozzle | ISA1932 nozzle [ISO5167-1 1991/ISO5167-3 2003] | ||||
Long radius nozzle [ISO5167-1 1991/ISO5167-3 2003] | |||||
ASME FLOW NOZZLES [ASME MFC-3M 1989] | |||||
Venturi | Venturi nozzle [ISO5167-1 1991/ISO5167-3 2003] | ||||
Classical Venturi tube "as cast" convergent section [ISO5167-1 1991/ISO5167-4 2003] | |||||
ASME Venturi Tubes With a rought Cast or Fabricated Convergent [ASME MFC-3M 1989] | |||||
Crassical Venturi Tubes With a machined convergent section [ISO5167-1 1991/ISO5167-4 2003] | |||||
ASME Venturi Tubes With a machined convergent section [ASME MFC-3M 1989] | |||||
Classical Venturi tube with a rought-welded sheet- iron convergent section [ISO5167-1 1991/ISO5167-4 2003] | |||||
Density compensation of fluid | General fluid | DIPPR (Physical property database) | |||
Natural gas | AGA No. 8, ISO 12213 | ||||
Steam | IAPWS-IF97 Water and Steam, 1997 | ||||
Manual mode | Flow factors being input manually | ||||
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | ||||
Certificates | FM, CENELEC ATEX, IECEx | ||||
Output | [HART protocol type] Dual output of 4 to 20 mA with pulse signals [ FOUNDATION fieldbus type] FOUNDATION fieldbus,2-wire system with digital communication | ||||
HART Protocol Revision* | HART protocol revision can be selected from 5 or 7 when ordering. The protocol revision can be changed by user configuration. | ||||
Supply voltage | HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) Fieldbus:9 to 32 V DC | ||||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) -30 to 80 deg C (-22 to 176 deg F) (with integral indicator) | ||||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | ||||
Maximum working pressure | 32 MPa (4500 psi) | ||||
Mounting | 2-inch pipe mounting | ||||
Wetted parts material | Capsule | 316L SST (Diaphragm material is Hastelloy C-276) | |||
Cover flange | 316 SST | ||||
Housing | Cast aluminum alloy | ||||
Flow configuration tool | EJXMVTool™ EJX-MV Configuration DTM (FSA120) |
*Note: Large size font is recomended for viewing. |
Model | Application | Type | Capsule | Measurement Span | Maximum Working Pressure | |||
kPa | inH2O | MPa | psi | |||||
EJX110A | Differential Pressure | Traditional- Mounting*1 | F M H V | 0.1 to 5 0.5 to 100 2.5 to 500 0.07 to 14MPa | 0.4 to 20 2 to 400 10 to 2000 10 to 2000 psi | 16 25 25 25 | 2300 3600 3600 3600 | |
EJX115A | Flow | Integral Orifice | F M H | 1 to 5 2 to 100 20 to 210 | 4 to 20 8 to 400 80 to 830 | 16 16 16 | 2300 2300 2300 | |
EJX118A | Differential Pressure & Liquid Level with Remote Seals | Extended Flush Combination | M H | 2 to 100 10 to 500 | 8 to 400 40 to 2000 | Based on Flange Rating | ||
EJX120A | Draft Range | Traditional- Mounting*1 | E | 0.025 to 1 | 0.1 to 4 | 50 kPa | 7.25 | |
EJX130A | Differential Pressure & Liquid Level | Traditional- Mounting*1 | M H | 1 to 100 5 to 500 | 4 to 400 20 to 2000 | 32 32 | 4500 4500 | |
EJX210A | Liquid Level, (Closed or Open Tank) | Flush Extended | M H | 1 to 100 5 to 500 | 4 to 400 20 to 2000 | Based on Flange Rating | ||
EJX310A | Absolute (Vacuum) Pressure*2 | Traditional- Mounting*1 | L M A B | 0.5 to 10 1.3 to 130 0.0175 to 3.5 MPa 0.08 to 16 MPa | 0.15 to 2.95 inHg 0.39 to 38 inHg 2.5 to 500 psi 12 to 2300 psi | 10 kPa 130 kPa 3.5 16 | 2.95 inHg 38 inHg 500 2300 | |
EJX430A | Gauge Pressure | Traditional- Mounting*1 | H A B | 2.5 to 500 0.0175 to 3.5 MPa 0.08 to 16 MPa | 10 to 2000 2.5 to 500 psi 12 to 2300 psi | 500 kPa 3.5 16 | 2000 inH2O 500 2300 | |
EJX438A | Gauge Pressure with Remote Seal | Flush | A B | 0.035 to 3.5 MPa 0.16 to 16 MPa | 5 to 500 psi 23 to 2300 psi | Based on Flange Rating | ||
Extended | A B | 0.06 to 3 MPa 0.46 to 7 MPa | 8.6 to 430 psi 66 to 1000 psi | |||||
EJX440A | High Gauge | Traditional- Mounting*1 | C D | 0.25 to 32 MPa 0.25 to 50 MPa | 36 to 4500 psi 36 to 7200 psi | 32 50 | 4500 7200 | |
EJX510A EJX530A | Absolute & Gauge Pressure*2 | Direct- Mounting | A B C D | 8 to 200 0.04 to 2 MPa 0.2 to 10 MPa 1 to 50 MPa | 1.16 to 29 psi 5.8 to 290 psi 29 to 1450 psi 145 to 7200 psi | 200 kPa 2 10 50 | 29 290 1450 7200 | |
EJX610A EJX630A | A B C D | 2 to 200 0.01 to 2 MPa 0.05 to 10 MPa 0.35 to 70 MPa | 0.3 to 29 psi 1.5 to 290 psi 7.3 to 1450 psi 50.8 to 10150 psi | 200 kPa 2 10 70 | 29 290 1450 10150 | |||
EJX910A | Multi- Variable Pressure Transmitter | Traditional- Mounting*1 | L M H | 0.1 to 10 0.5 to 100 2.5 to 500 | 0.4 to 40 2 to 400 10 to 2000 | 16 25 25 | 2300 3600 3600 | |
EJX930A | M H | 1 to 100 5 to 500 | 4 to 400 20 to 2000 | 32 32 | 4500 4500 |
*1: | Traditional-Mounting is 1/4NPT or Rc1/4 process connection (1/2NPT or Rc1/2 with process adapter). |
*2: | Measurement values in Absolute for Absolute Pressure Transmitter. |
Why do you choose us?
1. 100% original package product, 100% quality assurance.
If you find a fake product. Please contact us without hesitation!
We afford the shipment cost! We send you a new product asking zero
cent!
2. Varied payment methods.
We adopt Paypal, T/T, Alibaba Trade Assurance order, and other
methods. If you can not trust us , you can choose to pay it the
other way! 100% make your money safe!
We mainly supply Yokogawa flow meters, Emerson 475 field
communicator, Emerson AMS Trex Device communicator, Siemens
pressure transmitter, Honeywell transmitter, and the Honeywell BW
gas analytics.
Wuhan Xieyuan Automation Equipment Co., Ltd
Telephone:86-027-85583233
Mobile Phone:86-18671080257
Fax:86-027-85309780
Contact : victor@whxyauto.com
Skype:victordu963@gmail.com
Whatsapp & Viber are available
Address:6-C9,Caishen Commercial Plaza,Hankou Railway Station