Voltage Calibrator - Current Calibrator

  • Signal source: DCV (Max. 30V), DCA (Max. 24 mA)
  • Measurement: DCV (Max. 30V), DCA (Max. 100 mA)
  • Features: Auto step (4 to 20mA), 20mA SINK, Sweep function
  • Options: CA11E-2 Includes rubber boot, strap and accessory case

Specifications - Model CA11E-1

FeaturesSource and Measuring of Voltage and Current: Generates and measures voltages up to 30 V DC and currents up to 24 mA DC.
Improved display resolution for current: The generation/measurement resolution has improved to 0.001 mA.
24 V (20 mA)/Loop check function: Enables measurement of generated current signals while supplying loop power to two-wire transmitter. Load current: Max. DC22 A
20 mA SINK Function: Absorbs the voltage supplied from an external power supply to its H terminal and simulates a two-wire transmitter making it ideal for loop checks.
4-20 mA and 1-5 V DC Step-up/down Function: The output level can be changed between 4-8-12-16-20 mA signals by one touch for the 4-20 mA DC output, and between 1-2-3-4-5V signals for the 1-5 V DC output, for efficient calibration work.
Sweep Function: Increases and decreases the output level to the preset level at a constant rate for the selected sweep time (16 or 32 seconds). The sweep function and sweep time are set by the internal dip switches.
Standard AccessoriesCarrying Case
Power SupplyFour 1.5-V alkaline batteries (ANSI AA-size) or dedicated AC adapter (sold separately)
Battery LifeApprox. 25 hours for 20 mA DC output (with a load of 5 V)
When generating a signal continuously on alkaline batteries
Approx. 50 hours for 5 V DC output (with a load of 10k? or greater) When generating a signal continuously on alkaline batteries
Automatic Power-OffApprox. 10 minutes (Can be canceled by DIP switch setting)
Generation Signal Level SettingBy four-digit up/down keys
Response of GeneratorApprox. 1 second (from when the output begins to change until when the output level falls within the specified accuracy)
Maximum Allowable30 VDC or less between each terminal and ground
Measurement DisplayApprox. 1 update/sec.
Update interval Display7 segments LCD
Operating Temperature/Humidity Range0 to 50°C and 20 to 85%RH (no condensation)
Storage Temperature/Humidity Range-20 to 50°C and 90%RH or less (no condensation)
DimensionsApprox. 192 (W) x 92 (H) x 42 x (D) mm (Excluding protrusions)
Width192 mm
Height92 mm
Thickness42 mm
WeightApprox. 440 g (including batteries)
Additional FeaturesComplete Protection (CA11E)
Dip Switches (inside battery compartment)
Longer Lead Cables
Rubber Boot
Runs on 1.5 V AA-size Batteries or AC Adapter
Simple and Easy Calibration

 

Additional Features

  • Choose either "rubber boot" or "carrying case"
    Rubber boot, strap and accessory case can be chosen as standard accessories to improve impact resistance and make it easier to carry. (The calibrator cannot be stored in the carrying case when the rubber boot is attached.) The roomy case easily holds the calibrator without having to disconnect the lead cables.
  • Automatic Power-off
    Power is turned off automatically if the calibrator is not touched for 10 minutes, prolonging battery life.
  • Runs on 1.5 V AA-size Batteries or AC Adapter
    The handy calibrators can run on the built-in 1.5-V ANSI batteries or an AC power supply using the AC adapter (sold separately).
  • Longer Lead Cables
    The slightly longer than usual lead cables of 1.7 m (approximately 0.1 Ω for both cables) allow easy cable connection even if the handy calibrator is put on the floor.
  • Compact and Lightweight
    Almost the same size and weight as a hand-held digital multimeter, this calibrator is designed for use in the field.
  • Simple and Easy Calibration
    For the CA11E and CA12E, There is performing calibrations during periodic maintenance as they can be simply calibrated by the up/down keys.
  • Complete Protection (CA11E)
    The complete protector protects the circuit against short-circuiting of the voltage output terminals and application of a voltage (of up to 30 V) to the output terminals, etc. due to misconnection.
  • Dip Switches 
    (inside battery compartment)
 CA11ECA12E
Switch NumberONOFFONOFF
1Sweep functionSweep function -offThe built-in RJC is on.External RJC is on
232 s16 s°F°C
32424PT100-IPTS68PT100-ITS90
4Automatic power-off is disabled.Automatic power-offAutomatic power-off is disabled.Automatic power-off

 

Specifications - Model CA11E-2

FeaturesSource and Measuring of Voltage and Current: Generates and measures voltages up to 30 V DC and currents up to 24 mA DC.
Improved display resolution for current: The generation/measurement resolution has improved to 0.001 mA.
24 V (20 mA)/Loop check function: Enables measurement of generated current signals while supplying loop power to two-wire transmitter. Load current: Max. DC22 A
20 mA SINK Function: Absorbs the voltage supplied from an external power supply to its H terminal and simulates a two-wire transmitter making it ideal for loop hecks.
4-20 mA and 1-5 V DC Step-up/down Function: The output level can be changed between 4-8-12-16-20 mA signals by one touch for the 4-20 mA DC output, and between 1-2-3-4-5V signals for the 1-5 V DC output, for efficient calibration work.
Sweep Function: Increases and decreases the output level to the preset level at a constant rate for the selected sweep time (16 or 32 seconds). The sweep function and sweep time are set by the internal dip switches.
Standard AccessoriesAccessory case
Rubber Boot
Strap
Power SupplyFour 1.5-V alkaline batteries (ANSI AA-size) or dedicated AC adapter (sold separately)
Battery LifeApprox. 25 hours for 20 mA DC output (with a load of 5 V)
When generating a signal continuously on alkaline batteries
Approx. 50 hours for 5 V DC output (with a load of 10k? or greater) When generating a signal continuously on alkaline batteries
Automatic Power-OffApprox. 10 minutes (Can be canceled by DIP switch setting)
Generation Signal Level SettingBy four-digit up/down keys
Response of GeneratorApprox. 1 second (from when the output begins to change until when the output level falls within the specified accuracy)
Maximum Allowable30 VDC or less between each terminal and ground
Measurement DisplayApprox. 1 update/sec.
Update interval Display7 segments LCD
Operating Temperature/Humidity Range0 to 50°C and 20 to 85%RH (no condensation)
Storage Temperature/Humidity Range-20 to 50°C and 90%RH or less (no condensation)
DimensionsApprox. 192 (W) x 92 (H) x 42 x (D) mm (Excluding protrusions)
Width192 mm
Height92 mm
Thickness42 mm
WeightApprox. 440 g (including batteries)
Additional FeaturesCarrying Case
Complete Protection (CA11E)
Dip Switches (inside battery compartment)
Longer Lead Cables
Runs on 1.5 V AA-size Batteries or AC Adapter
Simple and Easy Calibration


 

Additional Features

  • Choose either "rubber boot" or "carrying case"
    Rubber boot, strap and accessory case can be chosen as standard accessories to improve impact resistance and make it easier to carry. (The calibrator cannot be stored in the carrying case when the rubber boot is attached.) The roomy case easily holds the calibrator without having to disconnect the lead cables.
  • Automatic Power-off
    Power is turned off automatically if the calibrator is not touched for 10 minutes, prolonging battery life.
  • Runs on 1.5 V AA-size Batteries or AC Adapter
    The handy calibrators can run on the built-in 1.5-V ANSI batteries or an AC power supply using the AC adapter (sold separately).
  • Longer Lead Cables
    The slightly longer than usual lead cables of 1.7 m (approximately 0.1 Ω for both cables) allow easy cable connection even if the handy calibrator is put on the floor.
  • Compact and Lightweight
    Almost the same size and weight as a hand-held digital multimeter, this calibrator is designed for use in the field.
  • Simple and Easy Calibration
    For the CA11E and CA12E, There is performing calibrations during periodic maintenance as they can be simply calibrated by the up/down keys.
  • Complete Protection (CA11E)
    The complete protector protects the circuit against short-circuiting of the voltage output terminals and application of a voltage (of up to 30 V) to the output terminals, etc. due to misconnection.

Panel Designs Common to Both Models

  • Power Switch
  • Up/Down Keys
    Used to set the output signal level. A pair of up/down keys is conveniently located immediately below each digit in the LCD panel.
  • Output On/Off Switch
    (Output signal can set ON/OFF)
  • Range Selection Rotary Switch
    The rotary switch simplifies range selection: just leave the switch set to the most frequently used range.
  • Dip Switches 
    (inside battery compartment)
 CA11ECA12E
Switch NumberONOFFONOFF
1Sweep functionSweep function -offThe built-in RJC is on.External RJC is on
232 s16 s°F°C
32424PT100-IPTS68PT100-ITS90
4Automatic power-off is disabled.Automatic power-offAutomatic power-off is disabled.

Automatic power-off

 

 

 

 

ModelDescriptionCA11E-2Voltage/Current Calibrator with rubber boot, strap and accessory case Signal source: DCV (Max. 30V), DCA (Max. 24 mA) Measurement: DCV (Max. 30V), DCA (Max. 100 mA) Features: Auto step (4 to 20mA), 20mA SINK, Sweep function Standard Accesories: Rubber booCA11E-1Voltage/Current Calibrator with carrying case Signal source: DCV (Max. 30V), DCA (Max. 24 mA) Measurement: DCV (Max. 30V), DCA (Max. 100 mA) Features: Auto step (4 to 20mA), 20mA SINK, Sweep function Standard Accesories: Carrying Case

 

 

 

 

Hot Products

Yokogawa EJX910A Multivariable Transmitter Product Description Yokogawa EJX910A Multivariable ...
Multivariable transmitter The multivariable transmitter 266JSH is able, thanks to multisensor ...
Multivariable transmitter The multivariable transmitter 266JST is able, thanks to multisensor ...
Multivariable transmitter The multivariable transmitter 266JRT with remote diaphragm seals is able, ...
HKXY Original and genuine ABB System 800xA AC 800M Communication interfaces AB CI853 3BSE018103R1 ...
IEC outdoor vacuum circuit breaker OVB-VBF Medium Voltage circuit breaker with spring mechanism ...