Weight Indicator Bagging Controller For 25KG Packing Weighing Control
 
Software Function
1. Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration and I/O Testing functions available.
2. Zero Upon Power Up, Zero Auto-tracking, Manual/Auto Zero and Zero Calibration available.
3. Load Calibration and Loss Calibration functions available.
4. 100 Recipes for packing control.
5. Optional ‘Auto Correct Inflight’ function.
6. Optional ‘Pause for Tolerance Alarm’ and ‘Auto Dribble Re-feed’ functions.
7. Optional ‘Batch Target Control’ function [With Batch Count Target or Batch Weight Target finished, the packing process will stop automatically].
8. Optional ‘Flow Control’ function for Bucket Scale.
 
Outline Size [W×H×D]
7”: 226.5 × 163 × 36 mm.
10.2”: 274 × 193 × 40 mm.​
 


Error Messages

MessageAlarm CauseSolution
RAM FaultThe chip RAM is damaged.Replace the chip RAM.
EEPROM FaultThe chip EEPROM is damaged.Replace the chip EEPROM.
Parameter ErrorThe chip EEPROM is damaged.Replace the chip EEPROM.
Weighing Signal ErrorWeighing signal reversed or not connected.Connect the loadcell correctly.
ADC FaultThe chip ADC is damaged.Replace the ADC module.
Over ADC RangeWeighing signal exceeds A/D conversion range.

1. Check if the loadcell is connected.
2. Check if the capacity of loadcell is too small.
3. Check if the loading weight is too big.

Overload AlarmWeight > (Scale Capacity + 9 × Scale Division).

1. Check if the set value of parameter [102] ‘Scale Capacity’ is reasonable.
2. Check if the loadcell is connected.
3. Check if the capacity of loadcell is too small.
4. Check if the loading weight is too big.

Internal Data-bus Fault Please contact manufacturer.

 
Power Supply Terminal

No.PinDescription
DC24VDC24V[±20%] Power Input Port
1DC Input -.
2+DC Input +.
For separating the controller from the interference of the driving devices, the DC24V power supply of the controller should not be shared by the DI/DO.

 
Installation Mode

 
Size Option:
7 Inch One:
Outline Size [W×H×D]: 226.5 × 163 × 36 mm
Panel Cut-out Size [W×H]: 215 × 152 mm
 
10 Inch One:
Outline Size [W×H×D]: 274 × 193 × 40 mm
Panel Cut-out Size [W×H]: 261 × 180 mm
 
System Diagram For APP1.1 1-Bucket Scale

 
System Diagram For APP1.2 2-Bucket Scale[1-scale]

 
System Diagram For APP1.3 2-Bucket Scale[2-Bag]Mode

 
Delivery

















































Hot Products

Belt Weigher Indicator Loss-in-weight Weighfeeder Controller for Conveyor Scale Suitable for Ration ...
Belt Feeder Scale with Weight Totalizing & High Anti-jam for Industrial Environment BST100-E21 ...
Touch Screen Liquid Filling Machine Indicator, Suitable for Liquid/Gas/Powder Ration Filling Scales ...
Sorting Check Weighing Indicator, Controller For Automatic Flipper Type Checkweigher Scales ...
Four Scales Packaging Weight Scale Controller, Weight Indicator For Industrial Weighing Systems ...
Product Description: Weighing controller BST100-E11 is a panel mounted one, with high accuracy 0.5%...