High-frequency Sampling Anti-vibration Filter Belt Weigher Indicator With Weight Totalizing

 

    1. Main Features:

  • Suitable for belt weigher.
  • EMC design with high anti-jamming capability, suitable for industrial environment.
  • 32-bit ARM CPU with 72MHz & higher arithmetic speed.
  • 160×32 dots LCD display screen with yellow-green background for English display.
  • Menu&Shortcut mode operation with key tone.
  • High-precision ∑-△A/D conversion technology and broad-range speed pulse input circuit.
  • Max. Connection Quantity: 8 Loadcells (350Ω).
  • Auto-locking, Key-locking, Key-unlocking and Digital Setting&Calibration functions available.
  • Auto Zero Tracking, Speed Calibration and Belt Length Calibration functions available.
  • Optional AO [4~20mA] module for Flow signal output (COM1 port will be occupied).
  • 2 Optional communication ports for connecting IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
  • Corrosion-proof, water-proof, dust-proof and shock-proof shell for model wall-mounting.
  • Weight Records per shift/day/month of a year can be queried and printed.
  • With the multitasking mode, the weighing process will not be interrupted by parameter setting and the other operations.

   2. Technical Specification

  • Executing Standard
  • CMC GB/T 7724-2008PRC National Standard.

² OMIL R50:1997International Recommendation.

  • Accuracy Grade: 0.5.
  • Display
  • 160×32 dots LCD display screen with yellow-green background for English display.
  • Display Refreshing Time: Setting Range 0.1~2.0s.
  • Kaypad
  • 16-key English keypad.
  • Menu&Shortcut operation with key tone.
  • Loadcell Interface
  • Excitation Voltage/Max. Current: DC10V/250mA [8-350Ω loadcells].
  • Signal Input Range: 0~25mV.
  • Sampling Frequency: 200Hz.
  • ∑-△ADC: 24-bit, 100,000 internal code used.
  • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  • Gain Drift: ±5ppm/℃.
  • Non-linearity: 0.005%FS.
  • Speed Sensor Interface
  • Output Voltage/Max. Current: DC12V/100mA.
  • Speed Pulse Input Range: 0.5~3000Hz.
  • Analog Signal Interface
  • Optional AO [4~20mA] module for Flow signal output.
  • COM1 port will be occupied.
  • Non-linearity: 0.05%FS.
  • Digital Communication Interface
  • COM1: Optional RS232/RS485/RS422/Profibus-DP/Ethernet modules.
  • COM2: RS232.
  • Connectable: IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
  • Report Print
  • Weight Records per shift/day/month of a year can be queried and printed.

  • Operating Specification
  • Operating Voltage: AC220V±15%, 50/60Hz.
  • Max. Power Consumption: 10W.
  • Outline Size
  • Model Panel-mounting: 170×91×184 mm [W×H×D].
  • Model Wall-mounting: 235.5×227.5×119.5mm [W×H×D].
  • Model Explosion-proof: 340×390×205mm [W×H×D].
  • Panel Cut-out Size
  • Model Panel-mounting: 151×76mm [W×H].
  • Operating Temperature: -25℃ to +45℃.
  • Storage Temperature: -30℃ to +60℃.
  • Relative Humidity: Max. 85%RH.
  • Application Environment of Model Explosion-proof
  • Explosion gas environment: Zone 1&2.
  • Classes of explosion gas mixture: IIA, IIB.
  • Temperature grades of explosion gas mixture: T1~T6.
  • Ex-mark: Ex d IIB T6 Gb.
  • Protection Level
  • Front Panel of Model Panel-mounting: IP65.
  • Model Wall-mounting: IP65.
  • Model Explosion-proof: IP65.
  • Weight
  • Model Panel-mounting: Approx. 1.3kg.
  • Model Wall-mounting: Approx. 1.8kg.
  • Model Explosion-proof: Approx. 19.2kg.

    3. Operation Interface

    3.1 Model Panel-mounting / Wall-mounting Operation Interface

 

 

3.2 Model Panel-mounting / Wall-mounting Keypad Operation

If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory Adj.’, the Indicator will return to ‘Main Display Interface’ automatically.

 

Menu Operation
Key NameDescription
【MENU】Enter Main Menu / Exit.
【ENT】

Enter/Save.

Return to the initial display interface.

【▲】

Cursor shifts up or left.

Display the previous interface or option.

【▼】

Cursor shifts down or right.

Display the next interface or option.

【0~9】Digit Input.
Quick Operation
【LOCK】

Key-locking.

Key-unlocking.

【F1】Static Span Calibration with Hanging Weight.
【ZERO】Zero Calibration.
【CAL1】Dynamic Span Calibration.
【CAL2】Static Span Calibration with Chain Weight.
【SEG】Segmenting Span Correction.
【SPD】Speed Calibration.
【LEN】Belt Length Calibration.
【TIME】Date/Time Setting.
【CLS】Clear Screen.
【REC】Query and Print Weight Record.
【PRINT】Print.

 

Model Panel-mounting Installation

 

Model Wall-mounting Installation

 

Belt Weighing System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

Technical Specifications Power Supply: AC220V±15%, 50/60Hz, Max. 15W. Loadcell Excitation Voltage...
Belt indicator controller/Loss-in-weight Weighfeeder Controller with RS232/RS458 for belt weighing ...
TFT-Touch Ration Filling Controller, Liquid Filling Machine Controller/Indicator Main Features: 1. ...
Belt Weigher Indicator Loss-in-weight Weighfeeder Controller for Conveyor Scale Suitable for Ration ...
Belt Feeder Scale with Weight Totalizing & High Anti-jam for Industrial Environment BST100-E21 ...
Touch Screen Liquid Filling Machine Indicator, Suitable for Liquid/Gas/Powder Ration Filling Scales ...