JLSW-70D Water Cooled Screw Chiller MRI Equipment,CT Scanning Equipment,Refrigerated Centrifuge


Product Description:


Water-cooled screw chiller is a kind of refrigeration equipment for industrial use, mainly used to provide cooling and air conditioning services for large buildings such as factories, commercial centers, and office buildings. It lowers the temperature of water by circulating refrigerant, so that cold water is delivered to the area that needs to be cooled to achieve the effect of cooling, dehumidification and keeping the air fresh.

The main components of a water-cooled screw chiller are compressors, condensers, evaporators, and throttle valves. Among them, the screw compressor is the core part of the whole system, which increases its temperature and pressure by compressing the refrigerant, makes it dissipate heat in the condenser and cools it down, and then absorbs heat in the evaporator and lowers the temperature, forming cold water recirculation use.

The water-cooled screw chiller has the characteristics of high cooling efficiency, large cooling capacity, stable operation, low noise, and easy maintenance. It is suitable for places that require a lot of cooling, such as large buildings and industrial manufacturing enterprises. However, its installation and use costs are high, and it requires a large space and power energy support, so it is generally used for large-scale projects and commercial purposes.


 

 

 

Production Features:


Water-cooled screw chiller has the following characteristics:

1.High refrigeration efficiency: The water-cooled screw chiller uses a screw compressor, which has the advantages of high efficiency, low noise, low vibration, and good stability. It can quickly cool down and meet large-scale refrigeration needs.

 

2.Large refrigerating capacity: The water-cooled screw chiller has a large refrigerating capacity and is suitable for places requiring a large amount of cooling, such as large buildings and industrial manufacturing enterprises.

 

3.Good stability: The key components such as the compressor, condenser and evaporator of the water-cooled screw chiller are made of high-quality materials, with high durability and stability, and can run stably for a long time.

 

4.Simple maintenance: The maintenance of the water-cooled screw chiller is relatively simple. It only needs basic maintenance such as regular cleaning, inspection and filter replacement to maintain its normal operation.

 

5.Environmental protection and energy saving: The water-cooled screw chiller uses environmentally friendly refrigerants and has a high energy efficiency ratio. At the same time, it can realize energy saving and environmental protection benefits through linkage control with other systems.

 

6.Strong adaptability: The water-cooled screw chiller can be combined in various forms according to the needs to meet the refrigeration requirements of different occasions and different needs. It is a highly flexible refrigeration equipment.

 

 

 

Working Principle:


The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.


2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.


3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.


4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.


Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.

 

 

 

 

 

Techinical Parameters:

 

ModelJLSW-30DJLSW-40DJLSW-50DJLSW-60DJLSW-80DJLSW-100DJLSW-120DJLSW-150D
Cooling capacityKW/h100140180200260370430550
TR28.539.851.256.973.9105.2122.3156.4
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
CompressorType Semi-hermetic screw
PowerKW22303641568093118
electric currentA3951657195135156198
RefrigerantType R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg16.522.227.533.444.455.666.582.6
Evaporator  shell and tube
Flowm³/h17.222.429.33343.964.275.295.3
DiameterinchG2.5"G3"G3"G3"G3"G4"G4"G4"
CompressorType shell and tube
Flowm³/h22.429.235.242.957.884.3101.1123.9
DiameterinchG2.5"G3"G3"G3"G3"G4"G4"G4"
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm22002250235024502500290030003000
Wmm80080080090090090015001500
Hmm15001600165017501800185015001550
Unit weightKg960990126013801520183021502580

 

 

ModelJLSW-170DJLSW-200DJLSW-230DJLSW-260DJLSW-280DJLSW-310DJLSW-350DJLSW-400D
Cooling capacityKW/h6207108309301020113012701530
TR176.3201.9236264.4290321.3361.1435
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
CompressorType Semi-hermetic screw
PowerKW130150175200225250281325
electric currentA218253295335390432480553
RefrigerantType R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg93.8111.2126.8144.1155.4170.9193.2220.9
Evaporator  shell and tube
Flowm³/h108.6126.3144.9163.8176.4196.5222.4252.6
DiameterinchG5"G5"G6"G6"G8"G8"G8"G8"
CompressorType shell and tube
Flowm³/h141.1166.2190.9215.8232.4258.6290.8333.2
DiameterinchG5"G5"G6"G6"G8"G8"G8"G8"
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm36003600360036503650370037004200
Wmm15001500150016001650175017501750
Hmm16501650170017001700175018001800
Unit weightKg30503200345037804060433046004820

 

 

 


Application Industry:


There are many devices in medical laboratories and medical equipment that require chillers to provide refrigeration and cooling functions. The following are some commonly used medical laboratories and medical equipment that require chillers:

 

1.Magnetic resonance imaging equipment (MRI): MRI equipment needs to use cooling water in the refrigerant circulation system to reduce the temperature to ensure the normal operation of the equipment.

 

2.CT scanning equipment: CT scanning equipment needs to use cooling water to reduce the temperature of the X-ray tube to ensure the normal operation of the equipment.

 

3.Chemical analysis instruments: In medical laboratories, many chemical analysis instruments need to use cooling water to reduce the temperature inside the instrument to ensure the accuracy and stability of the instrument.

 

4.Refrigerated centrifuges: Refrigerated centrifuges need to use refrigerant to cool the centrifuge tubes and rotors of the centrifuge to ensure the stability and accuracy of the samples in the experiment.

 

5.Medical cold therapy equipment: Medical cold therapy equipment needs to use cooling water to lower the temperature inside the device to produce cold therapy effects such as pain relief and swelling reduction.

 

In short, chillers play an important role in medical laboratories and medical equipment, which can provide refrigeration and cooling functions to ensure the normal operation of equipment and the accuracy of experimental results.

 

      
  Automotive Manufacturing           Chemical Engineering                  Electronics Industry                Electroplating Industry

 

     

  Injection Molding Industry           Pharmaceutical Industry           Plastic Packaging Industry               Printing Industry

 

 

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

 

 

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

 

 

Precautions for the use of medical chillers?


Medical chillers are one of the commonly used refrigeration equipment in medical equipment. In order to ensure the normal operation and safe use of medical chillers, the following are some precautions for use:

 

1.Installation location: The medical chiller should be installed in a dry, ventilated, dust-free, non-corrosive gas and suitable temperature place.

 

2.Power wiring: The power wiring of the medical chiller should comply with national standards and manufacturer's regulations. Do not change it at will, so as not to cause electrical failure or safety accident.

 

3.Cooling water pipeline: The cooling water pipeline of the medical chiller should be installed correctly, and the interface should be fastened to prevent leakage. Check whether the waterway is unobstructed before use.

 

4.Maintenance: The medical chiller should be cleaned, disinfected and maintained regularly to ensure the normal operation and service life of the equipment.

 

5.Temperature control: The medical chiller should be adjusted according to the required temperature setting to ensure the stability of the cooling water.

 

6.Safe operation: The medical chiller should pay attention to safe operation during use to prevent equipment failure or accidents.

 

7.Prevention of overload: The medical chiller should avoid overload operation during use, so as not to affect the life and use effect of the equipment.

 

In short, the correct use of medical chillers can ensure the normal operation of medical equipment and improve the quality and efficiency of medical services. When using, you should pay attention to the above points to ensure the safety and reliability of the medical chiller.

Hot Products

JLSF-100HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
JLSF-75HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
Product Description: Mold Cooling Water Chiller is a cooling equipment specially used in the mold ...
JLSF-25HP Air Cooled Water Chiller Space-Saving And Durable For Research Facilities Product ...
Product Description: Aluminum-plastic blister packaging machine and heat-sealing machine circulation ...
JLSW-100D Water Cooled Screw Chiller Chemical, Pharmaceutical, Food, Beverage, Metal Processing, ...