Home Companies Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

JLSK-12HP Water Cooled Scroll Chiller , Cooling Chiller Machine 220V 380V 50Hz 60Hz

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Add: No.19,Second Street,Huangling Road,Lubian Village,Chashan Town,Dongguan,Guangdong,China.

Contact name:Jlschiller

Inquir Now

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

JLSK-12HP Water Cooled Scroll Chiller , Cooling Chiller Machine 220V 380V 50Hz 60Hz

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

JLSK-12HP Water-Cooled Scroll Chiller

 

Product Description:


Water-cooled scroll chiller is a common refrigeration equipment, mainly used in air conditioning, refrigeration, cooling and other applications in industrial and commercial fields. Its working principle is to realize the cooling effect by compressing the refrigerant.

Specifically, the water-cooled scroll chiller is composed of a compressor, evaporator, condenser, expansion valve, water pump, water tank, control system, etc. The refrigerant is compressed into a high-temperature and high-pressure gas in the compressor, then cooled by the condenser to become a high-pressure liquid, decompressed by the expansion valve, and then becomes a low-pressure liquid, absorbs heat through the evaporator and becomes a low-temperature and low-pressure vapor, and finally is compressed by the compressor again. Compressed into high-temperature and high-pressure gas to form a cycle.

The water-cooled scroll chiller is characterized by the use of a scroll compressor, which has higher energy efficiency than traditional screw and reciprocating compressors, and has the characteristics of high efficiency and energy saving. At the same time, the water-cooled scroll chiller adopts water-cooling method to dissipate heat, which has better heat dissipation effect and lower noise level than air-cooling method.

 

 

 

Production Features:


The advantages of water-cooled scroll chillers are:

1. High efficiency and energy saving: Due to the use of scroll compressors, water-cooled scroll chillers have higher efficiency and lower noise, which can effectively increase refrigeration capacity and reduce energy consumption.

 

2. Low noise: The working noise of the scroll compressor is lower than that of the traditional screw and centrifugal compressors, which can provide a more comfortable working environment.

 

3. Environmental protection: The water-cooled scroll chiller does not need to use Freon and other refrigerants that are harmful to the ozone layer, which is more environmentally friendly.

 

4. Low maintenance cost: Due to the simple structure of the scroll compressor, the maintenance cost is relatively low, and it is also more convenient.

 

It should be noted that the water-cooled scroll chiller needs to pay attention to factors such as the quality of the water source and the change of the water temperature during use, so as not to affect the cooling effect and the normal operation of the equipment.

 

 

Working Principle:


Water-Cooled Scroll Chiller is a cooling device used in refrigeration and air-conditioning systems, and its working principle is as follows:

Compression cycle: The refrigeration cycle of the water-cooled open chiller is realized by a compressor. The compressor sucks in low-temperature and low-pressure refrigerant gas and compresses it into high-temperature and high-pressure gas. Such high-temperature and high-pressure gas is cooled by a heat exchanger to become a high-temperature and high-pressure gas.

 

Heat exchange cycle: The high temperature and high pressure gas is cooled by water circulation in the heat exchanger. In this way, the refrigerant gas becomes a high-temperature and low-pressure gas.

 

Expansion cycle: The high-temperature and low-pressure refrigerant gas enters the evaporator through the expansion valve, thereby forming a low-temperature and low-pressure refrigerant gas. In the evaporator, the refrigerant gas absorbs heat from the air, thereby cooling the air.

 

Cooling cycle: After cooling in the evaporator, the refrigerant gas is drawn again into the compressor, thus starting a new refrigeration cycle.

 

Water circulation: The water circulation in the water-cooled open chiller is realized through the cooling tower and the cooling water pipeline. The refrigerant gas exchanges heat with the cooling water in the heat exchanger, transfers the heat to the cooling water, and raises the temperature of the cooling water. The cooling water passes through the spray system of the cooling tower to form water mist, which dissipates heat into the air. After the cooling water passes through the cooling tower, it is circulated to the heat exchanger again through the water pump to form a water cycle.

 

 

 

 

Techinical Parameters:

 

ModelJLSK-5HPJLSK-10HPJLSK-15HPJLSK-20HPJLSK-25HPJLSK-30HPJLSK-40HPJLSK-50HPJLSK-60HP
Cooling capacityKW15.53146.56277.593124155186
Kcal/h13,7502750041,25055,00068,75082,500110,000137,500165,000
Temperature range5~35(Below 0 can be customized)
Power supply3N-380V/415V 50HZ/60HZ
Total powerKW4.18.112.416.520.224.632.240.348.5
Chilled waterm³/h2.65.58.210.813.61621.226.531.8
Cooling waterm³/h3.26.810.313.917.220.527.334.240.8
CompressorTypeFully enclosed scroll/piston
Start methodY-△启动
Output PowerKW3.87.511.31518.822.53037.545.5
RefrigerantTypeR-22/R407C/R410A
Control methodTemperature Sensing External Pressure Equalizing Expansion Valve
Filling volumeKG2.557.510.512.51520.22530
EvaporatorTypeshell and tube
DiameterG1.5″G2″G2.5″G3″
CondenserType shell and tube
DiameterG1.5″G2″G2.5″G3″
Protective deviceHigh and low voltage switch, antifreeze protection, soluble plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
DimensionsLmm95012601600160018501850225022502600
Wmm500650650700700700850850850
Hmm122012201300130013001360142014201420
Unit weightKG150280460520600850105013801550

 

 


Application Industry:

 


Water-Cooled Scroll Chillers are widely used in refrigeration and air-conditioning systems in various industries, including but not limited to the following:

1.Industrial refrigeration: Water-cooled open chillers are widely used in the field of industrial refrigeration, such as cold storage, pharmaceuticals, chemicals, plastics, rubber, electronics, metallurgy, food, beverages and other industries.

 

2.Commercial air conditioning: Commercial buildings such as large shopping malls, office buildings, hotels, hospitals, etc. need to use water-cooled open chillers to maintain indoor temperature.

 

3.Transportation: Water-cooled open chillers are also widely used in the field of transportation, such as the cooling system of high-speed rail, aircraft, ships and other vehicles.

 

4.Energy field: Water-cooled open chillers are also widely used in the energy field, such as nuclear power plants, wind power generation, solar power generation and other fields.

 

      
  Automotive Manufacturing           Chemical Engineering                  Electronics Industry                Electroplating Industry

 

     

  Injection Molding Industry           Pharmaceutical Industry           Plastic Packaging Industry               Printing Industry

 

 

 

Upport and Services:


Water-Cooled Scroll Chillers technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

 

 

 

Packing and Shipping:


Water-Cooled Scroll Chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

 

 

 

What causes the water pump of the chiller to reverse, and how to deal with it?


Chiller water pump reversal is usually caused by the following reasons:

1. The phase sequence of the power supply is wrong: If the three-phase wiring sequence of the power supply is wrong, it will cause the motor to run in reverse and cause the water pump to reverse.

 

2. Control system failure: If the control system of the chiller fails, it may cause the water pump to reverse. For example, if the electrical components in the control system are damaged or poorly connected, it may cause the motor to run in reverse.

 

3. Mechanical failure of the water pump: If the water pump itself has mechanical failures, such as damaged bearings, loose couplings, etc., it may also cause the water pump to reverse.

 

If it is found that the water pump of the chiller is reversed, the following measures should be taken immediately to deal with it:

1. Cut off the power supply: Cut off the power supply of the chiller immediately to avoid more damage caused by reverse rotation of the motor.

 

2. Eliminate the cause of the failure: check the power wiring of the chiller, the control system and the water pump itself, and find out the cause of the reverse rotation of the water pump.

 

3. Replacement of components: If the electrical components of the chiller are found to be damaged, they should be replaced in time; if the water pump itself has a mechanical failure, it should be repaired or replaced immediately.

 

4. Test run: After confirming that the fault has been dealt with, conduct a test run to check the normal operation of the chiller to ensure that the pump reverse problem will not occur again.

 

It should be noted that the reverse of the water pump of the chiller is serious and may cause damage to the equipment, so it should be dealt with and repaired in time. At the same time, the maintenance of the chiller should also be strengthened, and the equipment should be checked and maintained regularly to prevent failures.

Hot Products

JLSF-100HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
JLSF-75HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
Product Description: Mold Cooling Water Chiller is a cooling equipment specially used in the mold ...
JLSF-25HP Air Cooled Water Chiller Space-Saving And Durable For Research Facilities Product ...
Product Description: Aluminum-plastic blister packaging machine and heat-sealing machine circulation ...
JLSW-150D Reliable Water Cooled Screw Chiller For Pharmaceuticals, Hospitals, Laboratories Product ...